• Title/Summary/Keyword: immersed type

Search Result 163, Processing Time 0.026 seconds

Resistance Distribution in Thin Film Type SFCL Elements with Shunt Layers of Different Thicknes

  • Kim, Hye-Rim;Hyun, Ok-Bae;Lee, Seung-Yup;Yu, Kwon-Kyu;Kim, In-Seon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.41-45
    • /
    • 2003
  • Resistance distribution in thin film type SFCL elements of different shunt layer thickness was investigated. The 300 nm thick film of 2 inch diameter was coated with a gold layer and patterned into 2 mm wide meander lines. The shunt layer thickness was varied by ion milling the shunt layer with Ar ions, and also by having the shunt layer grown in different thickness. The SFCL element was subjected to simulated AC fault current for measurements. It was immersed in liquid nitrogenduring the experiment. The resistance distribution was not affected by the shunt layer thickness at applied voltages that brought the temperature of the elements to similar values. This result could be explained with the concept of heat transfer from the film to the surroundings. The resistance distribution was independent of the shunt layer thickness because thick sapphire substrates of high thermal conductivity dominated the thermal conductance of the elements.

A Possible diagnostic method of cable system using SI-PD measurement (충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구)

  • Kim, J.T.;Koo, J.Y.;Jang, E.;Cho, Y.O.;Kim, S.J.;Song, I.K.;Kim, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF

Fundamental Properties of Composite Board Made with Oriented Strand Board and Three Different Species of Veneer

  • Yanti, Hikma;Massijaya, Muh Yusram;Cahyono, Tekat Dwi;Novriyanti, Eka;Iswanto, Apri Heri
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.2
    • /
    • pp.239-248
    • /
    • 2019
  • This research presents an improvement of the physical and mechanical properties of composite board (com-ply) made of Oriented Strand Board (OSB) coated with wood veneer of Pine (Pinus merkusii), Avocado (Persea Americana) and Mahogany (Swietenia mahogany). 1.5 mm thick veneers of those three wood types were adhered to the surface of OSB using two adhesive types: epoxy and isocyanate. The adhesive with the glue spread of $250g\;m^{-2}$ applied using single glue line was spread and then cold pressed with the pressure of $15kg\;cm^{-2}$ for 3 hours. The research result showed an improving dimension stability of com-ply, but not found on all parameters of physical property test. The moisture content seemed to be influenced by the com-ply type, yet not related to its thickness swelling, water absorption and linear expansion. The exception took place in the parallel linear expansion when immersed for 2 hours. The highest to the lowest increases of MOE and MOR were consecutively found on OSB coated with wood veneer of Pine, Mahogany and Avocado. However, the increases were statistically insignificant. The highest increasing screw hold power was found at the com-ply type AE (avocado veneer and epoxy adhesive) that was by 28%.

VANISHING PROPERTIES OF p-HARMONIC ℓ-FORMS ON RIEMANNIAN MANIFOLDS

  • Nguyen, Thac Dung;Pham, Trong Tien
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.5
    • /
    • pp.1103-1129
    • /
    • 2018
  • In this paper, we show several vanishing type theorems for p-harmonic ${\ell}$-forms on Riemannian manifolds ($p{\geq}2$). First of all, we consider complete non-compact immersed submanifolds $M^n$ of $N^{n+m}$ with flat normal bundle, we prove that any p-harmonic ${\ell}$-form on M is trivial if N has pure curvature tensor and M satisfies some geometric conditions. Then, we obtain a vanishing theorem on Riemannian manifolds with a weighted $Poincar{\acute{e}}$ inequality. Final, we investigate complete simply connected, locally conformally flat Riemannian manifolds M and point out that there is no nontrivial p-harmonic ${\ell}$-form on M provided that the Ricci curvature has suitable bound.

Effect of Electrolytic Concentration on Frictional Behavior of Single Crystal Silicon (전해질 용액의 농도가 단결정 Si의 마찰거동에 미치는 영향)

  • 임대순
    • Tribology and Lubricants
    • /
    • v.7 no.2
    • /
    • pp.46-50
    • /
    • 1991
  • The Frictional behavior in single crystal (111) p-type silicon as influenced by electolytic solutions have been studied. Linear scratching by diamond indentor was carried out to show the variation of friction between silicon and diamond indentor immersed in electrolytic solutions. The results indicate that concentration of the solutions influence the fricational coefficient. In addition there is a correlation between measured zeta-potential and frictional coefficients. The zeta-potential in various concentrations was measured to estimate the variation of the Peierls energy. The proposed model predicts a minimum frictional coefficient near a concentration of $10^{-3}$ M/l NaOH in deionized water and explains the chemomechanical effect observed in this study.

Effect of Electrolyte Concentration on Water Permeation in Protective Coatings (방식도막에 있어서 물의 침투에 대한 전해질 용액의 영향)

  • 박진환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.206-212
    • /
    • 1998
  • The water permeation in protective coatings, which may greatly influence the corrosion protective property of these coatings, was studied using the electrochemical impedance spectroscopy technique. During the absorption of water in protective coatings immersed in electrolyte solution, the change of coating capacitance with concentration of electrolyte was determined from impedance measurements. When water absorption or desorption of coatings occured by exposing the coatings to electrolyte solutions of different concentration, increase in impedance caused by desorption of water was found to be higher in the case of thicker film. The amount of water absorbed in coatings changed with concentration of electrolyte. The water taken up in coatings from the solution of lower electrolyte concentration was deserted by contact with the solution of higher concentration. The uptake of water in protective coatings varied depending on the type of coating ingredient especially binder.

  • PDF

The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger (입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究))

  • Yoo, J.O.;Yang, H.J.;Cho, Y.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

Application of Membrane Processes to the Treatment of Wastewaters in Japan

  • Yamamoto, Kazuo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.39-50
    • /
    • 1995
  • The membrane processes that are commonly uscd in water and wastewater treatment are reverse osmosis (Ro), ultrafiltration (UF) and microfiltration (MF), which utilize pressure differentials. There is also nano-filtration (NF), or low-pressure reverse osmosis, which is positioned midway between conventional reverse osmosis and ultrafiltration. Reverse osmosis membranes reject dissolved ions, while ultrafiltration can be used to reject relatively larger molecules, such as protein, polysacchalides and so on. Microfiltration is capable of eliminating particles at submicron level. This paper summarizes the characteristics of MSAS process first, as it is the main membrane process applied to wastewater treatment. Two successful examples of the applications, the cases of individual building reuse system and nightsoil treatment, are then shown. The latest trend of new membrane applications, i.e., immersed-type MSAS is also introduced.

  • PDF

A COMPUTIONAL STUDY ON PERFORMANCE OF THE DENTAL AIR MOTOR HAND-PIECE (치과 치료기기용 에어 모터 핸드피스의 성능에 관한 수치 해석적 연구)

  • Sung, Y.J.;Lim, S.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.277-282
    • /
    • 2010
  • Imported vane type air motor and-piece is used widely in the domestic dental services. The imported hand-pieces are more than 90 percent in the domestic market. The air-motor unit of the hand-piece had not been developed inside of the country yet. Therefore it needs some research works. Purpose of this study is to design the air motor of the hand-piece for better performance. The geometry of the air-motor is based on product of NSK Company. The airflow of the air motor unit is simulated by Computational Fluid Dynamics. The performance analysis of the air motor units is investigated. ANSYS 12.0 CFX is used to analysis of the flowfield. Torque changes depends on spin calculated by the immersed solid method.

  • PDF

Numerical Solution of the Radiation Problem by the B-Spline Higher Order Kelvin Panel Method for a Half-Immersed Cylinder in Wave and Current

  • Hong, Do-Chun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.184-188
    • /
    • 2000
  • The improved Green integral equation of overdetermined type applied to the radiation problem for an oscillating cylinder in the presence of weak current is presented. A two-dimensional Green function for the weak current is also presented. The present numerical solution of the Improved Green integral equation by the B-spline higher order Kelvin panel method is shown to be free of irregular frequencies which are present in the usual Green integral equation.

  • PDF