• Title/Summary/Keyword: imaging physics

Search Result 635, Processing Time 0.026 seconds

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol

  • Jo, Yeseul;Kim, JeongJae;Park, Chul Hwan;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Kim, Pan Ki;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.296-315
    • /
    • 2019
  • Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Selection of High Redshift Quasars with Infrared Medium-deep Survey

  • Jeon, Yi-Seul;Im, Myung-Shin;Park, Won-Kee;Kim, Ji-Hoon;Jun, Hyun-Sung;Choi, Chang-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.77.2-77.2
    • /
    • 2010
  • A high redshift quasar is useful to investigate the early part of our universe. Since they are one of the brightest objects in the early universe, they can provide us with clues of the growth of super massive black holes and the early metal enrichment history. To discover the high redshift quasars, we designed a survey of wide area and moderate depth; Infrared Medium-deep Survey (IMS), a J-band imaging survey of ~200 $deg^2$ area where the multi-wavelength data sets exist. To obtain the J-band data, we are using the United Kingdom Infra-Red Telescope (UKIRT), and so far we have covered ~20 $deg^2$ with Y- or J-bands over three observing runs during 2009. We used color-color diagrams of multi-wavelength bands including i, z, Y, J, K, $3.6{\mu}m$ and $4.5{\mu}m$ to select high redshift quasars. The major challenge in the selection is many M/L/T dwarfs, low redshift galaxies, and instrumental defects that can be mistaken as a high redshift quasar. We describe how such contaminating sources can be excluded by adopting multiple color-color diagrams and eye-ball inspections. So far, our selection reveals two quasar candidates at z~7.

  • PDF

Current Status of the High Redshift Quasars Selection from Infrared Medium-deep Survey

  • Jeon, Yi-Seul;Im, Myung-Shin;Park, Won-Kee;Kim, Ji-Hoon;Jun, Hyun-Sung;Choi, Chang-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.37.1-37.1
    • /
    • 2010
  • A high redshift quasar is useful to investigate the early part of our universe. Since they are one of the brightest objects in the early universe, they can provide us with clues of the growth of super massive black holes and the early metal enrichment history. To discover the high redshift quasars, we designed a survey of wide area and moderate depth; Infrared Medium-deep Survey (IMS), a J-band imaging survey of ~200 deg2 area where the multi-wavelength data sets exist. To obtain the J-band data, we are using the United Kingdom Infra-Red Telescope (UKIRT), and so far we have covered~40 deg2 with Y- or J-bands over 36 observing nights. We used color-color diagrams of multi-wavelength bands including i, z, Y, J, K, $3.6{\mu}m$ and $4.5{\mu}m$ to select high redshift quasars. The major challenge in the selection is many M/L/T dwarfs, low redshift galaxies, and instrumental defects that can be mistaken as a high redshift quasar. We describe how such contaminating sources can be excluded by adopting multiple color-color diagrams and eye-ball inspections. So far, our selection reveals one quasar candidates at z~7 and a few candidates at z~6. In this poster presentation, we will update the current status of the quasar selection in the IMS fields.

  • PDF

DISCOVERY OF A STRONG LENSING GALAXY EMBEDDED IN A CLUSTER AT z = 1.62

  • WONG, KENNETH C.;TRAN, KIM-VY H.;SUYU, SHERRY H.;MOMCHEVA, IVELINA G.;BRAMMER, GABRIEL B.;BRODWIN, MARK;GONZALEZ, ANTHONY H.;HALKOLA, ALEKSI;KACPRZAK, GLENN G.;KOEKEMOER, ANTON M.;PAPOVICH, CASEY J.;RUDNICK, GREGORY H.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.389-392
    • /
    • 2015
  • We identify a strong lensing galaxy in the cluster IRC 0218 that is spectroscopically confirmed to be at z = 1.62, making it the highest-redshift strong lens galaxy known. The lens is one of the two brightest cluster galaxies and lenses a background source galaxy into an arc and a counterimage. With Hubble Space Telescope (HST) grism and Keck/LRIS spectroscopy, we measure the source redshift to be $z_S=2.26$. Using HST imaging, we model the lens mass distribution with an elliptical power-law profile and account for the effects of the cluster halo and nearby galaxies. The Einstein radius is $^{\theta}E=0.38^{+0.02{\prime}{\prime}}_{-0.01}$ ($3.2^{+0.2}_{-0.1}kpc$) and the total enclosed mass is $M_{tot}(<^{\theta}_E)=1.8^{+0.2}_{-0.1}{\times}10^{11}M_{\odot}$. We estimate that the cluster environment contributes ~ 10% of this total mass. Assuming a Chabrier IMF, the dark matter fraction within $^{\theta}E$ is $f^{Chab}_{DM}=0.3^{+0.1}_{-0.3}$, while a Salpeter IMF is marginally inconsistent with the enclosed mass ($f^{Salp}_{DM}=-0.3^{+0.2}_{-0.5}$).

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.

Developing Experimental Method of Real-time Data Transfer and Imaging using Astronomical Observations for Scientific Inquiry Activities (과학탐구활동을 위한 천문 관측 자료의 실시간 전송 및 영상 구현 실험 방법 개발)

  • Kim, Soon-Wook
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.183-199
    • /
    • 2012
  • Previous Earth Science textbooks have mostly lacked the latest astronomical phenomena frequently being reported in mass media such as popular science magazines. One of the main directions in the revision of the 2009 National Curriculum of Korea is to actively include those phenomena. Furthermore, despite a close link between astronomy and physics, the concept of modern physics has not been actively introduced in Earth Science textbooks and at the same time the linkage of physics to astronomy has rarely been studies in physics textbooks. Therefore, the concept of integration among different fields in science is emphasized in the new National Curriculum. Transient phenomena in the high energy astrophysical objects are examples that reflect such issue. The purpose of this study is to introduce transferring a real-time data and making imaging of astronomical observations using e-Science. As a first step, we performed the first experiment for a large data transfer of astronomical observation between Korea and Japan using KOREN, a National Research and Education Test Network. We introduce actively on-going fields of e-Science in observational activities of astronomy and astrophysics, and their close interrelationship with scientific inquiry activities and public outreach activities. We discuss our experiment in the scientific and educational aspects to the primitive e-Science activity in the Korean astronomical society and, in turn, provide a prospective view for its application to the scientific inquiry activities and public outreach activities in the upcoming commercial Gbps-level internet environments.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF