• Title/Summary/Keyword: imaging mode

Search Result 333, Processing Time 0.038 seconds

Differential antiangiogenic and anticancer activities of the active metabolites of ginsenoside Rg3

  • Maryam Nakhjavani;Eric Smith;Kenny Yeo;Yoko Tomita;Timothy J. Price;Andrea Yool;Amanda R. Townsend;Jennifer E. Hardingham
    • Journal of Ginseng Research
    • /
    • v.48 no.2
    • /
    • pp.171-180
    • /
    • 2024
  • Background: Epimers of ginsenoside Rg3 (Rg3) have a low bioavailability and are prone to deglycosylation, which produces epimers of ginsenoside Rh2 (S-Rh2 and R-Rh2) and protopanaxadiol (S-PPD and R-PPD). The aim of this study was to compare the efficacy and potency of these molecules as anti-cancer agents. Methods: Crystal violet staining was used to study the anti-proliferatory action of the molecules on a human epithelial breast cancer cell line, MDA-MB-231, and human umbilical vein endothelial cells (HUVEC) and compare their potency. Cell death and cell cycle were studied using flow cytometry and mode of cell death was studied using live cell imaging. Anti-angiogenic effects of the drug were studied using loop formation assay. Molecular docking showed the interaction of these molecules with vascular endothelial growth factor receptor-2 (VEGFR2) and aquaporin (AQP) water channels. VEGF bioassay was used to study the interaction of Rh2 with VEGFR2, in vitro. Results: HUVEC was the more sensitive cell line to the anti-proliferative effects of S-Rh2, S-PPD and R-PPD. The molecules induced necroptosis/necrosis in MDA-MB-231 and apoptosis in HUVEC. S-Rh2 was the most potent inhibitor of loop formation. In silico molecular docking predicted a good binding score between Rh2 or PPD and the ATP-binding pocket of VEGFR2. VEGF bioassay showed that Rh2 was an allosteric modulator of VEGFR2. In addition, SRh2 and PPD had good binding scores with AQP1 and AQP5, both of which play roles in cell migration and proliferation. Conclusion: The combination of these molecules might be responsible for the anti-cancer effects observed by Rg3.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change (소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화)

  • Kim, Se Young;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.846-856
    • /
    • 2005
  • Purpose : To measure the peak myocardial tissue velocities and patterns of longitudinal motion of atrioventricular(AV) annuli and assess body weight and heart rates-related changes in normal children. Methods : Using pulsed wave Tissue Doppler Imaging(TDI), we measured peak systolic, early and late diastolic myocardial velocities in 72 normal children at six different sites in apical-4 chamber (A4C) view and at four different sites in apical-2 chamber(A2C) view and compared those values with each other, also observing effects with body weights and heart rates. Longitudinal motions of the AV annuli were measured at three different sites in A4C. Results : There were no significant differences of the TDI parameters between gender, ECHO-machines and among the three Doctors performing TDI. Peak myocardial velocities were significantly higher at the base of the heart than in the mid-ventricular region and in the right lateral ventricular wall than in the left lateral ventricular wall or IVS. The TDI parameters showed no significant correlation with fractional shortening(%). Peak systolic and early diastolic myocardial velocities had no correlation with heart rates, but peak late diastolic velocities and A/E ratio correlated positively with heart rates. Correlations between the TDI parameters and body weight were inconsistent. Absolute longitudinal displacement and % displacement were not differ between gender and not correlated with the TDI parameters. Conclusion : We measured the peak myocardial velocities with TDI and the longitudinal motion of the AV annuli using M-mode echocardiography in normal children. With more large scale evaluation, we may establish reference values in normal children and broaden clinical applicabilities in congenital and acquired heart diseases.

Effects of Age, Breast Density and Volume on Breast Cancer Diagnosis: A Retrospective Comparison of Sensitivity of Mammography and Ultrasonography in China's Rural Areas

  • Wang, Feng-Liang;Chen, Fei;Yin, Hong;Xu, Nan;Wu, Xiao-Xiang;Ma, Jing-Jing;Gao, Shen;Tang, Jin-Hai;Lu, Cheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2277-2282
    • /
    • 2013
  • Purpose: Mammography has been confirmed as the only effective mode to improve the prognosis of patients with breast cancer in Western developed countries, but might not be a good choice in other areas of the world. One of the major challenges in China is to determine an optimal imaging modality for breast cancer screening. This study was designed to clarify the sensitivity of ultrasonography compared with that of mammography in rural China. Methods: We retrospectively studied the sensitivity of mammography and ultrasonography based on 306 breast cancer patients detected by the program of "screening for cervical cancer and breast cancer" performed in Chinese rural areas between January 2009 and December 2011, and analyzed the effects of age, breast density and volume on the sensitivity. Results: Stratified analysis showed that the sensitivity of breast ultrasonography was significantly higher than that of mammography in premenopausal patients (81.4% vs. 61.1%, p=0.02), in women ${\leq}$ 55 years of age (82.2% vs. 63.4%, p<0.01), in the high breast density group (American College of Radiology [ACR] levels 3-4) (85.9% vs. 60.6%, p<0.01) and in the small breast volume group (${\leq}$ 400 ml) (87.1% vs. 66.7%, p<0.01). Age had a significant effect on sensitivity of mammography (breast density and volume-adjusted odds ratio, 6.39; 95% confidence interval, 2.8-14.4 in age group > 55 compared to age group ${\leq}$ 45), but not that of ultrasonography. Neither breast density nor volume had significant effect on sensitivity of mammography or ultrasonography. Conclusions: Ultrasonography is more sensitive than mammography in detecting breast cancer in women under 55 year-old Chinese, especially in those with high-density and relatively small breasts.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

Functional MRI of Language: Difference of its Activated Areas and Lateralization according to the Input Modality (언어의 기능적 자기공명영상: 자극방법에 따른 활성화와 편재화의 차이)

  • Ryoo, Jae-Wook;Cho, Jae-Min;Choi, Ho-Chul;Park, Mi-Jung;Choi, Hye-Young;Kim, Ji-Eun;Han, Heon;Kim, Sam-Soo;Jeon, Yong-Hwan;Khang, Hyun-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.130-138
    • /
    • 2011
  • Purpose : To compare fMRIs of visual and auditory word generation tasks, and to evaluate the difference of its activated areas and lateralization according to the mode of stimuli. Materials and Methods : Eight male normal volunteers were included and all were right handed. Functional maps were obtained during auditory and visual word generation tasks in all. Normalized group analysis were performed in each task and the threshold for significance was set at p<0.05. Activated areas in each task were compared visually and statistically. Results : In both tasks, left dominant activations were demonstrated and were more lateralized in visual task. Both frontal lobes (Broca's area, premotor area, and SMA) and left posterior middle temporal gyrus were activated in both tasks. Extensive bilateral temporal activations were noted in auditory task. Both occipital and parietal activations were demonstrated in visual task. Conclusion : Modality independent areas could be interpreted as a core area of language function. Modality specific areas may be associated with processing of stimuli. Visual task induced more lateralized activation and could be a more useful in language study than auditory task.

Analysis of Subwavelength Metal Hole Array Structure for the Enhancement of Quantum Dot Infrared Photodetectors

  • Ha, Jae-Du;Hwang, Jeong-U;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Kim, Jong-Su;Krishna, Sanjay;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.334-334
    • /
    • 2013
  • In the past decade, the infrared detectors based on intersubband transition in quantum dots (QDs) have attracted much attention due to lower dark currents and increased lifetimes, which are in turn due a three-dimensional confinement and a reduction of scattering, respectively. In parallel, focal plane array development for infrared imaging has proceeded from the first to third generations (linear arrays, 2D arrays for staring systems, and large format with enhanced capabilities, respectively). For a step further towards the next generation of FPAs, it is envisioned that a two-dimensional metal hole array (2D-MHA) structures will improve the FPA structure by enhancing the coupling to photodetectors via local field engineering, and will enable wavelength filtering. In regard to the improved performance at certain wavelengths, it is worth pointing out the structural difference between previous 2D-MHA integrated front-illuminated single pixel devices and back-illuminated devices. Apart from the pixel linear dimension, it is a distinct difference that there is a metal cladding (composed of a number of metals for ohmic contact and the read-out integrated circuit hybridization) in the FPA between the heavily doped gallium arsenide used as the contact layer and the ROIC; on the contrary, the front-illuminated single pixel device consists of two heavily doped contact layers separated by the QD-absorber on a semi-infinite GaAs substrate. This paper is focused on analyzing the impact of a two dimensional metal hole array structure integrated to the back-illuminated quantum dots-in-a-well (DWELL) infrared photodetectors. The metal hole array consisting of subwavelength-circular holes penetrating gold layer (2DAu-CHA) provides the enhanced responsivity of DWELL infrared photodetector at certain wavelengths. The performance of 2D-Au-CHA is investigated by calculating the absorption of active layer in the DWELL structure using a finite integration technique. Simulation results show the enhanced electric fields (thereby increasing the absorption in the active layer) resulting from a surface plasmon, a guided mode, and Fabry-Perot resonances. Simulation method accomplished in this paper provides a generalized approach to optimize the design of any type of couplers integrated to infrared photodetectors.

  • PDF

A Study on the 'Re-appearance of Picturing ' in the On-Line Community (온라인 커뮤니티에서의 픽처링 재현에 관한 연구)

  • Son, Keum-Sun;Yoon, Jun-Sung
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02b
    • /
    • pp.737-742
    • /
    • 2007
  • The concept of 'Picturing' is beyond the 'Illusion' of traditional art in the Digital Media era. It is a 'Suffering' of the 'Re-appearance' that is masquerade the 'Actual' as a 'Digital Apparition.' This study aims to concern the point of view on the above subject; the 'Picturing' through the analysis of communication problems in the digital era. To begin with, need to define the concept of 'Picturing' and how it is expected to have a role through the accessibility of medium use, intervention by body and images. Also, I suggest a new approach to 'Picturing' as a new mutual communication method. Body, Digital media, and Image. These three principles of 'Picturing' create huge benefits to our world/nature whether we want it or not. It seems to become more and more of powerful self-replicating organism. We have to be aware what sort of images are surrounding us and how transmitting it to where in/on our body via newest sophisticated media we use. 'Picturing' is an invasion of ordinary, no longer exists pleasure for body, no longer speaks intension of its next destination. It strongly self-grows and also controls us in the name of Digital media era. However, 'Picturing' is a mode of re-imaging activity and also suggestion of re-appearance practice.

  • PDF