• Title/Summary/Keyword: imaging material

Search Result 578, Processing Time 0.028 seconds

Optimum Image Compression Rate Maintaining Diagnostic Image Quality of Digital Intraoral Radiographs

  • Song Ju-Seop;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2000
  • Purpose: The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed image. Materials and Methods: The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner (Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity, specificity and k value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level was compared with that of the original image files. Results: No significant difference was found between original and the corresponding images up to 7% (1 : 14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1 : 14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. Conclusion: 1 : 14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  • PDF

A Study of Polarimetric Properties of Comet C/2013 US10 (Catalina) in Optical and Near-Infrared Wavelength Regions

  • Kwon, Yuna Grace;Ishiguro, Masateru;Kuroda, Daisuke;Hanayama, Hidekazu;Kawabata, Koji S.;Akitaya, Hiroshi;Itoh, Ryosuke;Nakaoka, Tatsuya;Toda, Hiroshi;Yoshida, Michitoshi;Kawai, Nobuyuki;Watanabe, Jun-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.50.2-50.2
    • /
    • 2016
  • Polarization is a rich source of information on the physical properties of astronomical objects. In particular, scattered sunlight by optically thin media (e.g., cometary comae) shows linear polarization of light, which highly depends on the phase angle (an angle between the Sun-Comet-Earth), wavelengths, and physical properties of cometary dust particles such as size, composition, and structures. Here, we present a study of polarimetric properties of non-periodic comet C/2013 US10 (Catalina) in optical and near-infrared wavelength regions obtained from imaging, spectroscopy, and polarimetric observations taken on UT 2015 December 17 - 19 welcoming its (probably) first close approach to the Earth. In this presentation, we want to introduce our progress since the last Korean Astronomical Society meeting (at BEXCO, Busan, 2016 April 14 - 15) especially in terms of spatial variations of degree of linear polarization (DOLP) and its possible scenarios to explain the correlations with other observational results. In particular, we found that there is strong anti-correlation between the gas/dust flux ratio and DOLP at the cometocentric distance of $(2-5){\times}104 km$. Besides, within 10 arcseconds in radii (corresponding to inner coma region of 104 km from the center), the inverse relationship of these two parameters does not hold anymore. We conjecture that the rapid outward increase of DOLP can be supported by either the sublimation/evaporation of icy volatiles, disaggregation of cometary dust particles ejected from the nucleus, and/or difference of dominant dust particle sizes. From our results, we can conclude that comet C/2013 US10 (Catalina) corroborates rather indefinite traditional classification of poalrimetric classes of comets, and provides good opportunity to study less processed material which probably cherishes its memory at the formation epoch of the Solar System.

  • PDF

Template therapy for mouth opening limitation by temporomandibular joint disorders (턱관절원판 전방 변위로 인한 개구 장애의 템플레이트 치료)

  • Lee, Gi-Cheol;Shin, Seung-Woo;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2010
  • Introduction: Limited mouth opening is a representative clinical symptom of temporomandibular disorders (TMD) with anterior disc displacement without reduction (ADDWOR). Various treatment methods have been proposed for patients with ADDWOR. This study examined the clinical effectiveness of template therapy for patients with mouth opening difficulty due to the ADDWOR. Material and Methods: A total of 14 patients (female 12, male 2, average age: $29.1{\pm}14.4$), who had been treated in the template clinic, Sooncheonhyang University Bucheon Hospital, from January of 2006 to December of 2008, were enrolled in this study. The subjects were selected according to the following criteria: more than 2 weeks after the onset of locking, mouth opening range <35 mm, and confirmed ADDWOR without a synovial pathology by magnetic resonance imaging (MRI). All patients were treated with the template appliance, instructed to wear it while sleeping and exercise for at least 10 hours per day. The maximum mouth opening (MMO) range and pain recognition scores before and after template therapy were recorded and compared. A paired t-test and Wilcoxon's signed rank test were used for statistical analysis. Results: After the periodical follow up, significant improvement in the opening range was observed in the template treatment group. The average MMO range before treatment was $30.2{\pm}3.5mm$ and the average MMO after treatment and follow up was $47.1{\pm}4.7mm$. The mean amount of mouth opening increment was $16.9{\pm}5.4mm$ (P<0.01) and the pain recognition scores before and after treatment was also improved.(P=0.001) Conclusion: The template appliance proved to be efficient for the treatment of TMD with a closed lock and painful joint due to ADDWOR.

Prediction of Cement Volume for Vertebroplasty Based on Imaging and Biomechanical Results

  • Lee, Sung-Jae;Tack, Gye-Rae;Lee, Seung-Yong;Jun, Bong-Jae;Lim, Do-Hyung;Shin, Jung-Woog;Kim, Jeong-Koo;Shin, Kyu-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1041-1050
    • /
    • 2001
  • Control of bone cement volume (PMMA) may be critical for preventing complications in vertebroplasty, the percutaneous injection of PMMA into vertebra. The purpose of this study was to predict the optimal volume of PMMA injection based on CT images. For this, correlation between PMMA volume and textural features of CT images was examined before and after surgery to evaluate the appropriate PMMA amount. The gray level run length analysis was used to determine the textural features of the trabecular bone. Extimation of PMMA volume was done using 3D visualization with semi-automatic segmentation on postoperative CT images. Then, finite element (FE) models were constructed based on the CT image data of patients and PMMA volume. Appropriate material properties for the trabecular bone were assigned by converting BMD to elastic modulus. Structural reinforcement due to the changes in PMMA volume and BMD was assessed in terms of axial displacement of the superior endplate. A strong correlation was found between the injected PMMA volume and the area of the intertrabecular space and that of trabecular bone calculated from the CT images (r=0.90 and -0.90, respectively). FE results suggested that vertebroplasty could effectively reinforce the osteoporotic vertebra regardless of BMD or PMMA volume. Effectiveness of additional PMMA injection tended to decrease. For patients with BMD well lower than 50mg/ml, injection of up to 30% volume of the vertebral body is recommended. However, less than 30% is recommended otherwise to avoid any complications from excessive PMMA because the strength has already reached the normal level.

  • PDF

Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden

  • Park, Sa-Beom;An, So-Youn;Han, Won-Jeong;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.154-164
    • /
    • 2017
  • Purpose: Measurement of the root surface area (RSA) is important in periodontal treatment and for the evaluation of periodontal disease as a risk factor for systemic disease. The aim of this study was to measure the RSA at 6 mm below the cementoenamel junction (CEJ) using the Mimics software (Materialise, Leuven, Belgium). Methods: We obtained cone-beam computed tomography (CBCT) data from 33 patients who had visited the Department of Oral and Maxillofacial Radiology of Dankook University Dental Hospital. The patients comprised 17 men and 16 women aged from 20 to 35 years, with a mean age of 24.4 years. Only morphologically intact teeth were included in our data. Because the third molars of the maxilla and mandible have a high deformation rate and were absent in some participants, they were not included in our research material. Results: The CBCT data were reconstructed into 3-dimensional (3D) teeth models using the Mimics software, and the RSA at 6 mm below the CEJ was separated and measured using 3-Matic (Materialise). In total, 924 3D teeth models were created, and the area at 6 mm below the CEJ could be isolated in all the models. The area at 6 mm below the CEJ was measured in all teeth from the 33 patients and compared based on sex and position (maxilla vs. mandible). Conclusions: In this study, we demonstrated that it was feasible to generate 3D data and to evaluate RSA values using CBCT and the Mimics software. These results provide deeper insights into the relationship between periodontal inflammatory burden and systemic diseases.

Use of spherical coordinates to evaluate three-dimensional facial changes after orthognathic surgery

  • Yoon, Suk-Ja;Wang, Rui-Feng;Ryu, Sun-Youl;Hwang, Hyeon-Shik;Kang, Byung-Cheol;Lee, Jae-Seo;Palomo, Juan M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose: This study aimed to assess the three-dimensional (3D) facial changes after orthognathic surgery by evaluating the spherical coordinates of facial lines using 3D computed tomography (CT). Materials and Methods: A 19-year-old girl was diagnosed with class III malocclusion and facial asymmetry. Orthognathic surgery was performed after orthodontic treatment. Facial CT scans were taken before and after orthognathic surgery. The patient had a menton deviation of 12.72 mm before surgery and 0.83 mm after surgery. The spherical coordinates of four bilateral facial lines (ramal height, ramal lateral, ramal posterior and mandibular body) were estimated from CT scans before and after surgery on the deviated and opposite side. Results: The spherical coordinates of all facial lines changed after orthognathic surgery. Moreover, the bilateral differences of all facial lines changed after surgery, and no bilateral differences were zero. Conclusion: The spherical coordinate system was useful to compare differences between the presurgical and postsurgical changes to facial lines.

The Value of MRI in Diagnosis of Peripheral Nerve Disorders (말초신경질환에서 자기공명영상의 진단적 가치)

  • Lee, Han Young;Lee, Jang Chull;Kim, Il-Man;Lee, Chang-Young;Ikm, Eun;Kim, Dong Won;Yim, Man Bin
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1120-1126
    • /
    • 2001
  • Objective : The development of magnetic resonance neurography(MRN) has made it possible to produce highresolution images of peripheral nerves themselves, as well as associated intraneural and extraneural lesions. We evaluated the clinical application and utility of high-resolution MRN techniques for the diagnosis and treatment of a variety of peripheral nerve disorder(PND)s. Material and Method : MRN images were obtained using T1-weighted spin echo, T2-weighted fast spin echo with fat suppression, and short tau inversion recovery(STIR) fast spin-echo pulse sequences. Fifteen patients were studied, three with brachial plexus tumors, five with chronic entrapment syndromes, and seven with traumatic peripheral lesions. Ten patients underwent surgery. Results : In MRN with STIR sequences of axial and coronal imagings, signals of the peripheral nerves with various lesions were detected as fairly bright signals and were discerned from signals of the uninvolved nerves. Increased signal with proximal swelling and distal flattening of the median nerve were seen in all patients of carpal tunnel syndrome. Among the eight patients with brachial plexus injury or tumors, T2-weighted MRN showed increased signal intensity in involved roots in five, enhanced mass lesions in three, and traumatic pseudomeningocele in three. Other associated MRI findings were adjacent bony signal change, neuroma, root adhesion and denervated muscle atophy with signal change. Conclusion : MRN with high-resolution imaging can be useful in the preoperative evaluation and surgical planning in patients with peripheral nerve lesions.

  • PDF

Resistive Memory Switching in Ge5Se5 Thin Films

  • Kim, Jang-Han;Hwang, Yeong-Hyeon;Chung, Hong-Bay
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.326-326
    • /
    • 2014
  • It has been known since the mid 1960s that Ag can be photodissolved in chalcogenide glasses to form materials with interesting technological properties. In the 40 years since, this effect has been used in diverse applications such as the fabrication of relief images in optical elements, micro photolithographic schemes, and for direct imaging by photoinduced Ag surface deposition. ReRAM, also known as conductive bridging RAM (CBRAM), is a resistive switching memory based on non-volatile formation and dissolution of a conductive filament in a solid electrolyte. Especially, Ag-doped chalcogenide glasses and thin films have become attractive materials for fundamental research of their structure, properties, and preparation. Ag-doped chalcogenide glasses have been used in the formation of solid electrolyte which is the active medium in ReRAM devices. In this paper, we investigated the nature of thin films formed by the photo-dissolution of Ag into Ge-Se glasses for use in ReRAM devices. These devices rely on ion transport in the film so produced to create electrically programmable resistance states [1-3]. We have demonstrated functionalities of Ag doped chalcogenide glasses based on their capabilities as solid electrolytes. Formation of such amorphous systems by the introduction of Ag+ ions photo-induced diffusion in thin chalcogenide films is considered. The influence of Ag+ ions is regarded in terms of diffusion kinetics and Ag saturation is related to the composition of the hosting material. Saturated Ag+ ions have been used in the formation of conductive filaments at the solid electrolyte which is the active medium in ReRAM devices. Following fabrication, the cell displays a metal-insulator-metal structure. We measured the I-V characteristics of a cell, similar results were obtained with different via sizes, due to the filamentary nature of resistance switching in ReRAM cell. As the voltage is swept from 0 V to a positive top electrode voltage, the device switches from a high resistive to a low resistive, or set. The low conducting, or reset, state can be restored by means of a negative voltage sweep where the switch-off of the device usually occurs.

  • PDF

The Use of FDG PET for Nodal Staging of Non-Small-Cell Lung Cancer (비소세포폐암 환자의 국소 림프절 전이 발견을 위한 FDG PET의 이용)

  • 백희종;박종호;최창운;임상무;최두환;조경자;원경준;조재일
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.910-915
    • /
    • 1999
  • Background: Positron emission tomography(PEFT) using fluorine-18 deoxyglucose(FDG), showing increased FDG uptake and retention in malignant cells, has been proven to be useful in differentiating malignant from benign tissues. We indertook the prospective study to compare the accuracy of the whole-body FDG PET with that of the conventional chest computed tomography(CT) for nodal staging of non-small-cell lung cancers(NSCLC). Material and Method: FDG PET and contrast enhanced CT were performed in 36 patients with potentially resectable NSCLC. Each Imaging study was evaluated independently, and nodal stations were localized according to the AJCC regional lymph nodes mapping system. Extensive lymph node dissection(1101 nodes) of ipsi- and contralateral mediastinal nodal stations was performed at thoracotomy and/or mediastinoscopy. Image findings were compared with the histopathologic staging results and were analyzed with the McNema test(p) and Kappa value(k). Result: The sensitivity, specificity, positive predictive value, and negative predictive value of CT for ipsilateral mediastinal nodal staging were 38%, 68%, 25%, 79%, and 61%, and those of PET were 88%, 71%, 47%, 95%, and 75%(p>0.05, K=0.29). When analyzed by individual nodal group(superior, aortopulmonary window, and inferior), the sensitivity, specificity, positive predictive value, and negative predictive value of CT were 27%, 82%, 22%, 85%, and 73%, and those of PET were 60%, 87%, 92%, and 82%(p<0.05, k=0.27). Conclusion: FDG PET in addition to CT appears to be superior to CT alone for mediastinal staging of non-small cell lung cancers.

  • PDF

Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering (X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가)

  • Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • A Compton X-ray backscatter technique has been developed to quantitatively assess impact damage in quasi-isotropic laminated composites made by a drop-weight tester. X-ray backscatter imaging system with a slit-type camera is constructed to obtain a cross-sectional profile of impact-damaged laminated composites from the electron-density variation of the cross section. A nonlinear scattering model based on Boltsman equation is introduced to compute Compton X-ray backscattering field for the defect assessment. An adaptive filter is also used to reduce noises from many sources including quantum noise and irregular distributions of fibers and matrix in composites. Delaminations masked or distorted by the first delamination are detected and characterized effectively by the Compton X-ray backscatter technique, both in width and location, by application of error minimization algorithm.