• Title/Summary/Keyword: imaging material

Search Result 581, Processing Time 0.026 seconds

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Determination of Impact Source Location Using a Single Transducer and Time Reversal Technique (단일센서와 시간역전법을 이용한 판에서의 충격위치 결정에 관한 연구)

  • Jeong, Hyun-Jo;Cho, Sung-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a plate structure is presented in this paper. The method employs a single sensor and spatial focusing of time reversal (TR) acoustics. We first examine the TR focusing effect at the impact position and its surroundings through simulation and experiment. The imaging results of impact points show that the impact source location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testings of plate-like structures.

Three Cases of Extrahepatic Bile Duct Disorder: Diagnostic Imaging in Perspective (진단 영상을 위주로한 간외 담도계 질환 3례)

  • Lim Chang-yun;Jeong Yu-cheol;Oh Sun-kyoung;Jung Joo-hyun;Kim So-hee;Kim Nam-hyang;Seo Kyeong-won;Hwang Cheol-yong;Byeon Ye-eun;Kweon Oh-kyeong;Choi Min-cheol;Yoon Junghee
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.412-416
    • /
    • 2005
  • Three cases of extrahepatic bile duct disorder were presented. Two cases, a dog and a cat, were related to the obstruction of the extrhepatic bile duct, the other dog was affected with the gall bladder rupture. The clinical signs included anorexia, abdominal distension and vomiting. The laboratory test represented increased hepatic enzymes. On the radiography, hepatomegaly was seen in the obstructive cases, and ascites could be seen in the ruptured case. On the Ultrasonography, dilated gall bladder and extrahepatic bile duct were found in the obstructive cases, and there were ascites, indistinct gall bladder wall, dilation of gall bladder and extrabiliary tract, increased mesenteric echogenicity in the ruptured case. All presented were taken medication, surgical foreign material removal, or cholecystectomy showed complete recovery.

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

A study on Protector Performance Evaluation According to X-ray Scattering Distribution of Portable Radiation System (이동형 방사선 발생장치 차폐물 설치에 관한 연구)

  • Kim, Hyong-Gyun;Sung, Dong-Keon;Cho, Kyong-Mi;Kim, Sang-Beom;Kim, Jae-Young;Choi, Jun-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.85-92
    • /
    • 2009
  • This study, "The study about performance evaluations of mobile cover for X-ray's diffusion and distribution in mobile radiation" is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

  • PDF

Spindle cell lipoma of the posterior neck: A case report (목뒤부위에 발생한 방추세포 지방종의 치험례)

  • Park, Sun Hee;Yim, Young Min;Jung, Sung No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.233-236
    • /
    • 2009
  • Purpose: Spindle cell lipoma(SCL) is an uncommon subcutaneous soft tissue neoplasm that arises in the shoulder and posterior neck of older male patients. The imaging appearance of SCL is not pathognomonic and can display some features overlapping with liposarcoma. We report a case of SCL on the posterior neck. Method: The patient is a 50 - year - old man with a slowly enlarging subcutaneous mass on the right side of posterior neck. Computed tomographic imaging revealed a 7.0 cm sized, well - circumscribed, heterogenous and fatty mass with enhanced solid components. Whole body Fluorine - 18 Fluorodeoxyglucose Positron emission tomogram(FDG PET-CT) showed little increase of FDG uptake on the right posterior neck and there was no distant metastasis. Results: The mass was surgically removed. The resection margin was free of tumor on frozen biopsy. Histopathologic examination indicated spindle cell lipoma consisting of a mixture of mature adipocytes and uniform spindle cells within a matrix of mucinous material. Conclusion: Although CT image of solidtary mass in posterior neck is similar with the one of liposarcoma, we should consider that it may be a spindle cell lipoma if PET-CT and other systemic studies reveal no distant metastasis. And we should perform fine needle aspiration to differentiate SCL from malignant lesions.

Brain Abscess Uptake at TI-201 Brain SPECT (탈륨-201 SPECT에서 뇌농양 집적)

  • Lee, Won-Hyoung;Han, Eun-Ji;Yoo, le-Ryung;Chung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Choi, Yeong-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.339-341
    • /
    • 2007
  • A 22-year-old woman with a history of acute lymphoblastic leukemia was hospitalized for headache and vomiting. CT scan showed a well-defined, ring like enhancing mass in the left frontal lobe with surrounding edema and midline shift. Magnetic resonance imaging demonstrated a round homogeneous mass with a ring of enhancement in the left frontal lobe. Tl-201 brain SPECT showed increased focal uptake coinciding with the CT and MRI abnormality. Aspiration of the lesion performed through a burr hole yielded many neutrophils, a few lymphocytes and histiocytes with some strands of filamentous microorganism-like material. Modified AFB stained negative for norcardia. Gram stain showed a few white blood cells and no microorganism. Antibiotics were started and produced a good clinical response. After one month, CT scan showed markedly reduction in size and extent was observed.

A Study on the Interactive Art Created by Embodiment of 2-D Paintings Into 3-D Imaging (2차원 회화작품이 3차원 영상으로 구현되어 창작된 참여예술에 대한 연구)

  • 김진희
    • Archives of design research
    • /
    • v.14 no.3
    • /
    • pp.127-134
    • /
    • 2001
  • This study suggests a model of experimental visual artworks with interactive art forms in which 2-D paintings are transformed to interactive 3-D animation works. Multimedia programming was employed to evolve objective still paintings to the animation of computer 3-D images with respect to visual ideas derived from visual components in the still painting and to response to the reactions users. The format and technique of the art works are based upon the contents developed by the author and the research materials are selected from the surrealistic paintings of tile world-famous Belgian painter, Rene Magritte. In the present paper, following topics are discussed in detail: a study of various visual cases occurring in transforming still paintings to animation works containing interactive components; a study of 3-D imaging and image processing techniques to transform 2-D paintings to 3-D images; animation techniques for interaction and overall structuring techniques; multimedia programming and user interface.

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Design and Manufacture of an Off-axis Aluminum Mirror for Visible-light Imaging

  • Zhang, Jizhen;Zhang, Xin;Tan, Shuanglong;Xie, Xiaolin
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.364-371
    • /
    • 2017
  • Compared to one made of glass, an aluminum mirror features light weight, compact design, low cost, and quick manufacturing. Reflective mirrors and supporting structures can be made from the same material, to improve the athermal performance of the system. With the rapid development of ultraprecise machining technologies, the field of applications for aluminum mirrors has been developed rapidly. However, most of them are rotationally symmetric in shape, and are used for infrared applications. In this paper, the design and manufacture of an off-axis aluminum mirror used for a three-mirror-anastigmat (TMA) optical system at visible wavelengths is presented. An optimized, lightweight design provides a weight reduction of more than 40%, while the surface deformation caused by earth's gravity can meet the required tolerance. The two pieces of an off-axis mirror can be diamond-turned simultaneously in one setup. The centrifugal deformation of the off-axis mirror during single-point diamond turning (SPDT) is simulated through the finite-element method (FEM). The techniques used to overcome centrifugal deformation are thoroughly described in this paper, and the surface error is reduced to about 1% of the original value. After post-polishing, the form error is $1/30{\lambda}$ RMS and the surface roughness is better than 5 nm Ra, which can meet the requirements for visible-light imaging.