• 제목/요약/키워드: imaging material

검색결과 578건 처리시간 0.032초

Prefluorescent-Dye-Induced Fluorescent Imaging based on Polymeric Photobase Generators

  • Chae, Kyu-Ho;Choi, Won-San;Kim, Yoo-Ho
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.177-177
    • /
    • 2006
  • Copolymers containing oxime-urethane groups, which led to the formation of pendant amino groups photochemically, were applied to a fluorescent image-recording material through the reaction with fluorescamine, a prefluorescent dye for amino groups. This imaging method permits the fluorescent image to be erased or restored by treatment with base or acid. Copolymers containing phthalimide carbamate groups were applied to a bicolor fluorescent imaging material through the consecutive reaction with fluorescamine and rhodamine. A various colored fluorescent micropattern (green, red or red-yellow) was observed through the changes of excitation wavelength by using a conforcal microscope.

  • PDF

구리 잉크의 소성 특성 향상 (Improve the sintering property of copper inks.)

  • 송영아;김동훈;김성진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.66-66
    • /
    • 2010
  • 잉크젯용 저온 Cu ink의 소성 특성을 향상 시키기 위해 소성 분위기롤 조절 하였다. 일반적으로 Cu는 산화가 잘되는 물질로 환원 분위기에서 소성이 이루어져야만 하기 때문에 acid, alcohol, aldehyde, ether와 같은 환원제를 소성시 사용하였다. 또한 1종의 환원제가 아닌 2종의 환원제롤 일정 비율로 섞음으로써 환원력를 조절하여 소성 품질을 향상 시킬 수 있었으며, 이러한 환원 분위기 조절을 통하여 300도 이하 저온에서 소성이 가능하였다. 또한 optical microscopy와 field emission scanning electron microscopy를 통해 막 품질과 미세조직의 치밀도를 확인하였고 배선 재료로써의 적용을 위해 resistance를 측정 비교하였다.

  • PDF

Far lateral lumbar disc extrusion in a dachshund dog

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • 대한수의학회지
    • /
    • 제59권3호
    • /
    • pp.165-169
    • /
    • 2019
  • A 6-year-old Dachshund was presented with acute, non-localized pain without neurological dysfunction. Radiography revealed multiple calcifications of intervertebral discs and narrowing of disc space in the thoracolumbar region. Computed tomography and magnetic resonance imaging revealed calcified disc-like material entrapped in the left extraforaminal area and showed a displaced nerve root. Fenestration and removal of the extruded disc material were performed in a routine manner. Histopathological examination showed degenerative disc materials with severe calcification both in the nucleus pulposus and around the annulus fibrosis. Based on imaging, surgical, and histopathologic results, the dog was diagnosed with far lateral lumbar disc extrusion.

Imaging Plate에 기록된 전자회절자료의 해석 (Accurate Interpretation of Electron Diffraction Data Acquired by Imaging Plates)

  • 김영민;김윤중
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.195-204
    • /
    • 2003
  • Imaging plate에 기록된 전자회절 자료의 면간 거리 분석과 상동정시 나타나는 오차 요인들을 고찰하고 실험적인 보정방법을 도출하였다. 각각의 회절방향에 대한 radial intensity distribution plot과 실험적으로 도출된 면간 거리 보정식에 의해 전자회절 자료의 디지털 이미지에서 면간 거리 측정오차는 약 0.5%로 낮아짐을 알 수 있었다. Al 표준시료를 이용하여 imaging plate에 기록된 전자회절 자료의 면간 거리 편차 경향을 분석한 후 [001] gibbsite 시편에 동일한 실험적 보정을 수행하여 120분간의 전자빔 조사로부터 형성된 여러 전이 상들에 대한 면간 거리 측정 및 상 동정을 보다 정밀히 수행할 수 있었다. 그 결과, gibbsite로부터 형성된 주요 전이상들은 ${\chi}$-알루미나, ${\gamma}$-알루미나, ${\sigma}$-알루미나로 구성됨을 명확하게 동정할 수 있었다.

Thermoelectric Imaging of Epitaxial Graphene

  • 조상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.113.2-113.2
    • /
    • 2014
  • Heat is a familiar form of energy transported from a hot side to a colder side of an object, but not a notion associated with microscopic measurements of electronic properties. A temperature difference within a material causes charge carriers, electrons or holes, to diffuse along the temperature gradient inducing a thermoelectric voltage. Here we show that local thermoelectric measurements can yield high sensitivity imaging of structural disorder on the atomic and nanometre scales. Using this imaging technique, we discovered a defect-mediated dimensional evolution of strain-response patterns in epitaxial graphene with increasing thickness.

  • PDF

MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구 (Image Quality of Amorphous Selenium DR system using MTF measurement)

  • 석대우;박지군;최장용;남상희;강신원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

자기장의 균일성을 고려한 자기공명장치의 최적설계 (Optimal Design of an MRI Device Considering the Homogeneity of the Magnetic Field)

  • 이정훈;유정훈
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.654-659
    • /
    • 2008
  • This paper is to suggest a concept design of the permanent magnet type magnetic resonance imaging (MRI) device based on the parameter optimization method. Pulse currents in the gradient coils will introduce the effect of eddy currents in the ferromagnetic material, which will worsen the quality of imaging. In order to equalize the magnetic flux in the MRI device for good imaging, the eddy current effect in the ferromagnetic material must be taken into account. This study attempts to use the design of experiment (DOE) and the response surface method (RSM) for equalizing the magnetic flux of the permanent magnet type MRI device using that the magnetic flux can be calculated directly using a commercial finite element analysis package. As a result, optimal shapes of the pole and the yoke of the PM type MRI device can be obtained. The commercial package, ANSYS, is used for analyzing the magnetic field problem and obtaining the resultant magnetic flux.

일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템 (System of a Selenium Based X-ray Detector for Radiography)

  • 이동길;박지군;최장용;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

Local transport properties of coated conductors by laser-scan imaging methods

  • Kim, Gracia;Jo, William;Nam, Dahyun;Cheong, Hyeonsik;Moon, Seoung Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.1-4
    • /
    • 2016
  • To observe the superconducting current and structural properties of high critical temperature ($T_c$) superconductors (HTS), we suggest the following imaging methods: Room temperature imaging (RTI) through thermal heating, low-temperature bolometric microscopy (LTBM) and Raman scattering imaging. RTI and LTBM images visualize thermal-electric voltages as different thermal gradients at room temperature (RT) and superconducting current dissipation at near-$T_c$, respectively. Using RTI, we can obtain structural information about the surface uniformity and positions of impurities. LTBM images show the flux flow in two dimensions as a function of the local critical currents. Raman imaging is transformed from Raman survey spectra in particular areas, and the Raman vibration modes can be combined. Raman imaging can quantify the vibration modes of the areas. Therefore, we demonstrate the spatial transport properties of superconducting materials by combining the results. In addition, this enables visualization of the effect of current flow on the distribution of impurities in a uniform superconducting crystalline material. These imaging methods facilitate direct examination of the local properties of superconducting materials and wires.