• Title/Summary/Keyword: imaging material

Search Result 578, Processing Time 0.032 seconds

Characteristic Study of X-ray convert material by Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 X선 변환물질의 특성 연구)

  • Kim, Jin-Young;Park, Ji-Koon;Kang, Sang-Sik;Kim, So-Young;Jung, Eun-Sun;Nam, Sang-Hee;Kang, Sin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.418-421
    • /
    • 2003
  • Today, much terminologies such as noise spectrum, Sharpness, contrast, MTF had been defined for Image quality revaluation of radiation Image. Since development of Xeroradiography In the 1970s, Digital radiation detector that use amorphous selenium was developed. The aim of this research is to analyze physical phenomenon of digital radiation detector that use amorphous selenium. Result of Monte Carlo simulations on amorphous selenium based on physical properties(creation of electron-hole pairs) by induced x-ray are described. From the simulation, intrinsic point spread function(PSF) was found and used to observe modulation transfer function(MTF). We investigated how PSF and MTF changed with various x-ray energy. This result can be used to design digital x-ray detector based on a-Se.

  • PDF

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

A semi-automated method for integrating textural and material data into as-built BIM using TIS

  • Zabin, Asem;Khalil, Baha;Ali, Tarig;Abdalla, Jamal A.;Elaksher, Ahmed
    • Advances in Computational Design
    • /
    • v.5 no.2
    • /
    • pp.127-146
    • /
    • 2020
  • Building Information Modeling (BIM) is increasingly used throughout the facility's life cycle for various applications, such as design, construction, facility management, and maintenance. For existing buildings, the geometry of as-built BIM is often constructed using dense, three dimensional (3D) point clouds data obtained with laser scanners. Traditionally, as-built BIM systems do not contain the material and textural information of the buildings' elements. This paper presents a semi-automatic method for generation of material and texture rich as-built BIM. The method captures and integrates material and textural information of building elements into as-built BIM using thermal infrared sensing (TIS). The proposed method uses TIS to capture thermal images of the interior walls of an existing building. These images are then processed to extract the interior walls using a segmentation algorithm. The digital numbers in the resulted images are then transformed into radiance values that represent the emitted thermal infrared radiation. Machine learning techniques are then applied to build a correlation between the radiance values and the material type in each image. The radiance values were used to extract textural information from the images. The extracted textural and material information are then robustly integrated into the as-built BIM providing the data needed for the assessment of building conditions in general including energy efficiency, among others.

The determination of reference material for bone density by using bone phantom (골판톰을 이용한 골밀도측정 참조체의 결정)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.135-139
    • /
    • 2002
  • Purpose: To determine the proper reference step wedge for digital Cu-Equivalent Image analyzing systems for measurement of bone density. Meterials and Methods : Radiograms of lumbar vertebrae phantom (1g/㎠) with 3 test copper step wedges of 0.03, 0.05 and, 0.1 mm thickness unit were taken and analyzed using NIH image software on a Macintosh personal computer. Measured densities of the lumbar areas in the Cu-Equivalent images made by utilizing 3 different copper stepwedges were compared with a known bone density. Results: The values of r2 for all copper equivalent images were over 0.99. The mean Cu-Eq value of lumbar in copper equivalent image made by a 0.1 mm copper stepwedge was 0.22 ± 0.06 mm and converted to hydroxyapatite density of 1.03 g/㎠. The stepwedges of 0.03 and 0.05 mm produced results having higher values than the actual known bone density. They did not show the blue and green color level that appeared in lumbar on color enhanced image. Conclusion : A copper stepwedge of adequate thickness and range of steps which can express the range of density of bone being measured should be used.

  • PDF

Introduction of the Advanced Imaging Materials -Micro-encapsulating Treatment of Toner- (최신 화상 재료의 소개 -마이크로 캡슐 토너-)

  • Lee, Yong Kyu;Jeong, Kyoung Mo;Koseki, Ken'ichi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.6
    • /
    • pp.79-86
    • /
    • 2012
  • The aim of this general remarks is to introduce the results concerning the thermo physical, charging, developing and fusing characteristics of micro-encapsulated (MC) model toners in order to apply to the toner of electrophotographic system at the condition of a low temperature. In order to clarify the fusing mechanism of MC toner, rheological analysis of the toner was chosen. It was suggested that MC toner had a different fusing mechanism compared with non-MC toner. Some kinds of MC model toners showed a good result on adhesion test as well as cohesion test. Also, it was possible to get the good charging and development characteristic of MC toner for printing test with laser printer.

Synthesis and Characterization of Y2O3:Eu Fine Particle

  • Park, Ji-Koon;Kang, Sang-Sik;Kwak, Min-Gi;Choi, Seung-Suk;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.4
    • /
    • pp.169-172
    • /
    • 2005
  • [ $Y_2O_3:Eu$ ] powder was synthesized using a solution-combustion method by dissolving $(CH_3CO_2)_3Y$ and $(CH_3CO_2)_3$ Eu in methyl-alcohol solution. Results from X-ray diffractometery (XRD), thermogravimetry (TG)-differential thermal analysis (DTA) show that $Y_2O_3:Eu$ crystallizes completely when the dry powder is sintered at $500^{\circ}C$. The investigated optical properties were the photoluminescence emission spectra, the excitation spectra and luminescence decay curve. Europium (Eu) concentration had no observable effect on the optical spectrum which depended on the emission intensity. The mean lifetime of synthesized phosphors was $2.3\~2.6 ms$.

A Study on the 3D Representation of 2D Projection Data using Epipolar Geometry (Epipolar 기하학을 이용한 2차원 투영 데이터의 3차원 표현에 관한 연구)

  • Yu, Seon-Guk;Wang, Ge;Kim, Nam-Hyeon;Kim,Yong-Uk;Kim, Hui-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.212-219
    • /
    • 2002
  • In this paper, the epipolar geometry, genera17y used as a pin-hole camera model, is newly adapted to our proposed method that enables the affine reconstruction of the 3D object from two projected views. The proposed method models the projective projection of inherent X-ray imaging system, obviates the need to attach artifirially constructed material on the body, and requires none of the prior-knowledge regarding to intrinsic and extrinsic parameters of two X-ray imaging systems. The optimum numerical solution is obtained by applying the least mean square estimator to corresponding points on two projected X-ray planes. The performance of this proposed method is Quantitatively analyzed using computer synthesized model of Cochlear implantation electrodes. In simulated experiments, the propnsed method is insensitive to the added random noise, the scaling factor change, the center point change, and rotational angular change between two projection planes, as well as enables the stable 3D reconstruction in least square sense even in worst testing cases.

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

Clival lesion incidentally discovered on cone-beam computed tomography: A case report and review of the literature

  • Jadhav, Aniket B.;Tadinada, Aditya;Rengasamy, Kandasamy;Fellows, Douglas;Lurie, Alan G.
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.165-169
    • /
    • 2014
  • An osteolytic lesion with a small central area of mineralization and sclerotic borders was discovered incidentally in the clivus on the cone-beam computed tomography (CBCT) of a 27-year-old male patient. This benign appearance indicated a primary differential diagnosis of non-aggressive lesions such as fibro-osseous lesions and arrested pneumatization. Further, on magnetic resonance imaging (MRI), the lesion showed a homogenously low T1 signal intensity with mild internal enhancement after post-gadolinium and a heterogeneous T2 signal intensity. These signal characteristics might be attributed to the fibrous tissues, chondroid matrix, calcific material, or cystic component of the lesion; thus, chondroblastoma and chondromyxoid fibroma were added to the differential diagnosis. Although this report was limited by the lack of final diagnosis and the patient lost to follow-up, the incidental skull base finding would be important for interpreting the entire volume of CBCT by a qualified oral and maxillofacial radiologist.