• 제목/요약/키워드: imaging material

검색결과 581건 처리시간 0.025초

Long-standing chin-augmenting costochondral graft creating a diagnostic challenge: A case report and literature review

  • Badr, Fatma Fayez;Mintline, Mark;Ruprecht, Axel;Cohen, Donald;Blumberg, Barton R.;Nair, Madhu K.
    • Imaging Science in Dentistry
    • /
    • 제46권4호
    • /
    • pp.279-284
    • /
    • 2016
  • To our knowledge, the imaging features of costochondral grafts (CCGs) on cone-beam computed tomography (CBCT) have not been documented in the literature. We present the case of a CCG in the facial soft tissue to the anterior mandible, with changes mimicking a cartilaginous neoplasm. This is the first report to describe the CBCT imaging features of a long-standing graft in the anterior mandible. Implants or grafts may be incidental findings on radiographic images made for unrelated purposes. Although most are well-defined and radiographically homogeneous, being of relatively inert non-biological material, immune reactions to some grafts may stimulate alterations in the appearance of surrounding tissues. Biological implants may undergo growth and differentiation, causing their appearance to mimic neoplastic lesions. We present the case of a cosmetic autogenous CCG that posed a diagnostic challenge both radiographically and histopathologically.

적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단 (The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography)

  • 최만용;김원태
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.525-531
    • /
    • 2004
  • 본 고는 적외선 열화상의 개념과 적외선열화상 측정윈리 및 카메라 셋팅을 기술하고 적외선열화강(IRT)에 의한 비파괴검사(NDT)의 활용 및 비파괴검사의 진단에 대하여 살펴보았다. 적외선 열화상은 주어진 표면을 따라 온도에 관련된 열패턴의 평가를 통한 정기적인 비접촉, 비파괴 시험의 수행으로 초기에 장비 고장의 예방이 가능하다. 진단 활용으로서, 열적으로 가열된 내부결함이 있는 블록에 대하여 적외선열화상을 이용한 열화상 패턴을 비파괴 기법으로 평가하고, 결함과 열화상패턴간의 특성을 분석하여 열화상 평가 기법에 대하여 논하였다.

내로우 갭 적용을 위한 핫와이어 송급 레이저용접 - 고속촬영을 통한 와이어 용융/이행 현상과 아크 포메이션 분석 - (Hot Wire Laser Welding of Multilayer for Narrow Gap - Analysis of Wire Melting/Transfer and Arc Formation Phenomenon by High Speed Imaging -)

  • 김경학;방한서;방희선
    • Journal of Welding and Joining
    • /
    • 제34권5호
    • /
    • pp.26-32
    • /
    • 2016
  • In this study, Hot-wire laser welding (HWLW) without keyhole which deposits filler material by feeding hot wire into the process zone has been performed to increase process performance. From the analysis of High Speed Imaging (HSI), for higher voltage, the process is prone to arc formation and drop transfer, which is disagreeable transfer mode. It is necessary that arc formation and drop (globular) transfer should be avoided by lower voltage. Therefore, continuous wire melting and transfer mode is preferred when adopting this process. The HWLW technique has high potential in terms of performance, precision, robustness and controllability for thick section of narrow gap.

Efflorescence assessment using hyperspectral imaging for concrete structures

  • Kim, Byunghyun;Cho, Soojin
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.209-221
    • /
    • 2018
  • Efflorescence is a phenomenon primarily caused by a carbonation process in concrete structures. Efflorescence can cause concrete degradation in the long term; therefore, it must be accurately assessed by proper inspection. Currently, the assessment is performed on the basis of visual inspection or image-based inspection, which may result in the subjective assessment by the inspectors. In this paper, a novel approach is proposed for the objective and quantitative assessment of concrete efflorescence using hyperspectral imaging (HSI). HSI acquires the full electromagnetic spectrum of light reflected from a material, which enables the identification of materials in the image on the basis of spectrum. Spectral angle mapper (SAM) that calculates the similarity of a test spectrum in the hyperspectral image to a reference spectrum is used to assess efflorescence, and the reference spectral profiles of efflorescence are obtained from theUSGS spectral library. Field tests were carried out in a real building and a bridge. For each experiment, efflorescence assessed by the proposed approach was compared with that assessed by image-based approach mimicking conventional visual inspection. Performance measures such as accuracy, precision, and recall were calculated to check the performance of the proposed approach. Performance-related issues are discussed for further enhancement of the proposed approach.

수중음향 영상화를 위한 렌즈 제작 및 특성 평가 (Characteristics Evaluation of the Lens for Underwater Acoustic Imaging)

  • 조완호;권휴상;조요한;서희선
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

A novel reconstruction algorithm based on density clustering for cosmic-ray muon scattering inspection

  • Hou, Linjun;Zhang, Quanhu;Yang, Jianqing;Cai, Xingfu;Yao, Qingxu;Huo, Yonggang;Chen, Qifan
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2348-2356
    • /
    • 2021
  • As a relatively new radiation imaging method, the cosmic-ray muon scattering imaging technology can be used to prevent nuclear smuggling and is of considerable significance to nuclear safety. Proposed in this paper is a new reconstruction algorithm based on density clustering, aiming to improve inspection quality with better performance. Firstly, this new algorithm is introduced in detail. Then in order to eliminate the inequity of the density threshold caused by the heterogeneity of the muon flux in different positions, a new flux correction method is proposed. Finally, three groups of simulation experiments are carried out with the help of Geant4 toolkit to optimize the algorithm parameters, verify the correction method and test the inspection quality under shielded condition, and compare this algorithm with another common inspection algorithm under different conditions. The results show that this algorithm can effectively identify and locate nuclear material with low misjudging and missing rates even when there is shielding and momentum precision is low, and the threshold correcting method is universally effective for density clustering algorithms.

Opto-mechanical Design of Monocrystalline Silicon Mirror for a Reflective Imaging Optical System

  • Liu, Xiaofeng;Zhang, Xin;Tian, Fuxiang
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.236-243
    • /
    • 2022
  • Monocrystalline silicon has excellent properties, but it is difficult to design and manufacture silicon-based mirrors that can meet engineering applications because of its hard and brittle properties. This paper used monocrystalline silicon as the main mirror material in an imaging system to carry out a feasibility study. The lightweight design of the mirror is completed by the method of center support and edge cutting. The support structure of the mirror was designed to meet the conditions of wide temperature applications. Isight software was used to optimize the feasibility sample, and the optimized results are that the root mean square error of the mirror surface is 3.6 nm, the rigid body displacement of the mirror is 2.1 ㎛, and the angular displacement is 2.5" under the conditions of a temperature of ∆20 ℃ and a gravity load of 1 g. The optimized result show that the silicon-based mirror developed in this paper can meet the requirements of engineering applications. This research on silicon-based mirrors can provide guidance for the application of other silicon-based mirrors.

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

Image reconstruction algorithm for momentum dependent muon scattering tomography

  • JungHyun Bae;Rose Montgomery;Stylianos Chatzidakis
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1553-1561
    • /
    • 2024
  • Nondestructive radiography using cosmic ray muons has been used for decades to monitor nuclear reactor and spent nuclear fuel storage. Because nuclear fuel assemblies are highly dense and large, typical radiation probes such as x-rays cannot penetrate these target imaging objects. Although cosmic ray muons are highly penetrative for nuclear fuels as a result of their relatively high energy, the wide application of muon tomography is limited because of naturally low cosmic ray muon flux. This work presents a new image reconstruction algorithm to maximize the utility of cosmic ray muon in tomography applications. Muon momentum information is used to improve imaging resolution, as well as muon scattering angle. In this work, a new convolution was introduced known as M-value, which is a mathematical integration of two measured quantities: scattering angle and momentum. It captures the objects' quantity and density in a way that is easy to use with image reconstruction algorithms. The results demonstrate how to reconstruct images when muon momentum measurements are included in a typical muon scattering tomography algorithm. Using M-value improves muon tomography image resolution by replacing the scattering angle value without increasing computation costs. This new algorithm is projected to be a standard nondestructive radiography technique for spent nuclear fuel and nuclear material management.

Measurement of Drifting Mobility and Transit Time of Holes and Electrons in Stabilized a-Se Film

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.362-363
    • /
    • 2007
  • The transport property of stabilized amorphous selenium typical of the material used in direct conversion x-ray imaging devices was studied using the moving photo-carrier grating (MPG) technique and time-of-flight (TOF) measurements. For MPG measurement, the electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. For TOF measurement, a laser beam with pulse duration of 5ns and wavelength of 350 nm was illuminated on the surface of a-Se with thickness of $400{\mu}m$.

  • PDF