• 제목/요약/키워드: image vibration

검색결과 321건 처리시간 0.025초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

소음원의 모양을 들어서 상상할 수 있을까\ulcorner (Can We Hear the Shape of a Noise Source\ulcorner)

  • Kim, Yang-Hann
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.586-603
    • /
    • 2004
  • “소리의 비 가시성(非 可視性)”은 소음을 제어하고자 하는 공학자에게 주어진 근원적인 어려움 중의 하나이다. 따라서 이러한 비 가시성을 완화할 수 있는. 다시 말하면 소음을 볼 수 있는 방법에 대한 탐구는 많은 관심과 시도가 있어왔다. 이들 방법 중 대표적인 것으로 이론적 또는 수치적인 방법을 이용하여 소음을 가시화 하려는 많은 시도를 들 수 있다. 수치적인 방법의 경우에는 난류 유동의 가시화 분야에서 괄목할 만한 성과를 이루어왔으나 난류 소음의 가시화에는 부족한 상태이다 실험적인 방법의 경우는 마이크로폰 제작 기술의 발달로 인한 가격 인하로 많은 수의 마이크로본을 손쉽게 확보할 수 있게 되었고 매우 빠른 신호처리 기술의 발달이 확보됨으로써 많은 진전이 이루어졌으나, 가시화된 음장 정보의 정확한 해석 등이 여전히 어려운 분야로 남아있다. 또한 음장 가시화 결과에는 항상 유한한 측정 자료로 인한 오차가 포함되어 있으며, 이로 인하여 논문의 제목에서 강조한 바와 같이 소음인의 탐지 및 소음원의 공간적인 분포를 결정하는 데 어려움이 있다. 이 논문은 음장 가시화와 관련된 간략한 역사를 레오나르도 다빈치의 유명한 와류 유동 그림에서 출발하여 현대적 개념의 선형 혹은 평면형 마이크로폰 배열에 의해 수행되는 음향 홀로그래피 분야를 전반부에 설명하고, 음향 홀로그래피 구현에 있어서 발생하는 어려운 문제와 최근의 연구 동향을 후반부에 소개하는 방식으로 구성되어 있다. 최근의 문제 중에서는 자동차나 기차와 같이 이동하는 소음원을 가시화하기 위한 이동 후레임(moving frame)을 이용한 홀로그램 구성 방법과 닫힌 공간에서의 소음원 탐지를 위해 필요한 소리의 반사 효과 제거에 대하여도 기술하고 있다. 또한, 최근에 연구되는 또 다른 중요한 분야로서 “우리는 두 마리의 새가 지저귀는 것인지 아니면 한 마리의 새가 두 개의 목소리를 가지고 지저귀는 것인지 알 수 있을까?" 라는 질문으로 표현할 수 있는 공간상에 분포하는 소음원의 상호 의존관계를 구분하는 분야에 대한 문제 제기와 현실적인 접근 방법을 논하고 있다.

고기동 안정화 카메라 및 원격제어 셀프카메라를 적용한 캔위성 시스템 개발 (Development of A CanSat System Applying High Agility Camera and Remote Control Camera)

  • 김수현;박재현;김혜인;배기성;채봉건;오현웅
    • 항공우주시스템공학회지
    • /
    • 제12권3호
    • /
    • pp.86-96
    • /
    • 2018
  • 본 논문에서 제안한 캔위성은 2017년 캔위성 경연대회에 출전한 $HA+RC^2S$ CanSat (High Agility and Remote Control Camera System Can Satellite)이다. 주요임무는 수동진동감쇠기인 동흡진기를 사용하여 카메라를 회전시킨 직후에 발생하는 잔류진동을 감쇠하여 고품질의 영상획득이 가능한 고기동 안정화 카메라 시스템을 검증하는 것이다. 부가적으로는 지상국의 조이스틱을 사용하여 무선으로 제어되는 원격 제어 셀프카메라로 캔위성 자체의 이미지데이터를 획득하는 것이다. 본 논문에서는 임무 정의, 시스템 설계, 제작, 기능 및 성능시험, 최종 비행시험을 포함하는 $HA+RC^2S$ CanSat의 개발과정에 대해 서술하였다.

DGPS와 Motion Sensor를 이용한 선박 동적 거동특성 (Dynamic Behavior Character of Vessel Using DGPS and Motion Sensor)

  • 최철웅;김연수
    • 대한공간정보학회지
    • /
    • 제12권4호
    • /
    • pp.35-43
    • /
    • 2004
  • 다중빔 음향탐사 시스템(Multibeam Echosounder system : MBES)은 넓은 지역을 소해측량(swath)하여 전자해도 제작, 고정밀 DEM 획득, 동영상 제작 등에 활용하는 최신 수로측량기술이다. MBES의 정확도향상 연구를 위한 기초연구로서 DGPS와 움직임측정센서(Motion senser)의 측정값을 비교 분석하여 선박의 동적 거동특성을 연구하였다. DGPS를 선체 전후, 좌우에 설치하여 측량한 GPS 위치 값의 수신정확도는 Roll은 ${\pm}0.0016^{\circ}$, Pitch는 ${\pm}0.0009^{\circ}$로 움직임측정센서 값의 정확도 평가가 가능한 양호한 정도를 얻었다. DGPS와 움직임측정센서의 Heading, Pitch, Roll 상관관계는 모두 정상관 관계를 나타냈다. 또한, 각 변화량에 따른 편차량의 상관관계는 정상관 관계이나 탐사선의 급회전, 진동 등과 같은 요소에 의해 편차가 발생 될 것으로 사료된다. GPS에 의한 조위변화량, Heave값은 움직임측정센서 값과 유사하며, GPS속도는 설치장소에 따라 변화가 있어 영향이 가장 적은 선박의 중심선에 설치하는 것이 적당하다. MBES Processor 장치에 입력되는 자이로, 움직임측정센서 값이 DGPS 실시간 관측 값보다 자이로는 15초, Pitch, Roll, Heave는 13초 시간차가 있어 MBES 최종값의 정확도에 영향을 줄 수 있는 것으로 사료된다.

  • PDF

도시철도 차량 주행시 곡선스킬소음 실험 및 고찰 (Field Measurements and Review of the Curve Squeal Noise of Urban Railways)

  • 김재철;김관주;이준헌;김지용
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.165-172
    • /
    • 2017
  • 도심을 지나는 철도 궤도는 급격한 곡선 구간이 존재하며, 철도차량이 곡선부를 주행하며 발생시키는 높은 주파수의 스킬소음은 곡선부 인근에 소음 민원을 야기하고, 해당 구간 궤도의 마모를 과도하게 발생시킨다. 본 논문에서는 대표적 비선형, 과도 특성인 스킬소음의 현상을 정확하게 파악하기 위해서 실차를 대상으로 곡선부 스킬 소음실험을 수행하였다. 특정 대차내 4 차륜을 대상으로 스킬소음의 음압의 크기, 주파수 특성, 주행 속도 변화에 따른 영향, 차륜의 진동응답특성과 스킬소음의 연관관계를 파악하였다. 동시에 차륜과 레일의 접촉 위치의 변화를 촬영한 영상을 분석하여 스킬소음 발생시 차륜의 레일에 대한 상대적 움직임에 대한 현상을 살펴보았다. 철도 차량 곡선 주행시 스킬소음은 내측 전륜에서 가장 크게 발생하며, 이는 차륜의 횡방향 진동 응답 특성과 관련이 있다고 생각된다. 이 발생 스킬소음의 크기는 차량 속도 증가와는 직접적인 관련이 없음을 알 수 있었다.

확장현실 기반의 심폐소생술 교육 시스템의 사용성 평가 (Usability of CPR Training System based on Extended Reality)

  • 이영호;김선경;최종명;박건우;고영혜
    • 사물인터넷융복합논문지
    • /
    • 제8권6호
    • /
    • pp.115-122
    • /
    • 2022
  • 최근 병원 밖 심정지 환자의 생존율 향상을 위한 일반인 대상 심폐소생술 교육의 중요성이 강조되고 있다. 일반인 대상 효과적인 심폐소생술 교육을 위해 보다 정확하고 생동감 있는 교육전략이 필요하다. 이에 본 연구에서는 확장현실 기반의 심폐소생술 교육시스템을 개발하고 일반인을 대상으로 교육한 사용성 평가 결과를 제시한다. 3개의 응용프로그램으로 구성된 확장현실 기반 심폐소생술 교육시스템에서는 첫 번째 마네킹에 정합된 3D 심장 해부도를 스마트글라스에 전송하여 가슴압박 지점을 안내한다. 두 번째 응용프로그램은 스마트글라스를 통해 심폐소생술 과정에 대한 시·청각적 정보를 제공함과 동시에 스마트워치의 진동 알림을 전송하여 심폐소생술의 정확한 압박 속도를 안내한다. 세번째 Add on kit는 마네킹에 설치된 센서를 통하여 흉부 압박의 깊이와 속도에 대한 즉각적인 피드백 정보를 스마트폰으로 전송한다. 본 연구에 참여한 93명의 대상자는 확장현실 기반 심폐소생술 교육시스템이 현장감과 효과성 측면에서 긍정적이라 평가하였다. 확장현실 기술을 이용한 정합기술은 현장감과 몰입도를 높이고 자기 주도적 훈련을 쉽게 함으로서 심폐소생술 교육 운영 효율성 향상에 이바지할 수 있다.

전이 학습을 이용한 선박 기관실 기기의 분류에 관한 연구 (Machine Classification in Ship Engine Rooms Using Transfer Learning)

  • 박경민
    • 해양환경안전학회지
    • /
    • 제27권2호
    • /
    • pp.363-368
    • /
    • 2021
  • 선박 기관실은 기술의 발전으로 인해 자동화 시스템이 향상되었지만, 해상에서는 바람, 파도, 진동, 기기 노후화 등의 다양한 변수가 많아 자동화 시스템에서 계측되지 않는 풀림, 절단, 누유, 누수 등이 발생하므로 기관사는 주기적으로 순찰을 한다. 순찰 시에는 1명의 기관사만 순찰하는 경우도 있으며, 이는 고온고압 및 회전기기가 운전 중인 기관실에서 많은 위험요소를 가지고 있다. 기관사가 순찰 시에는 오감을 활용하며, 특히 시각에 의존한다. 본 논문에서는 로봇이 기관실을 순찰하며 기기의 특이사항을 검출하고 알려주는 기관실 순찰 로봇을 구현하기 위한 선행연구로서 선박 기관실 기기의 이미지를 합성곱 신경망을 이용하여 분류하였다. 선박 기관실의 이미지 데이터 셋을 구성한 후 사전 훈련된 합성곱 신경망 모델로 학습하였다. 학습한 모델의 분류 성능은 높은 재현율을 보였으며, 클래스 활성화 맵으로 이미지를 시각화 하였다. 데이터의 양이 제한적이어서 일반화할 수는 없지만, 각 선박의 데이터를 전이학습으로 학습시키면 적은 시간과 비용으로 각 선박의 특성에 맞는 모델을 구축할 수 있을 것으로 사료된다.

햅틱 피드백 장치를 이용한 치과 수술 시뮬레이션 (Dental Surgery Simulation Using Haptic Feedback Device)

  • 윤상연;성수경;신병석
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제12권6호
    • /
    • pp.275-284
    • /
    • 2023
  • 가상 현실 시뮬레이션은 다양한 분야에서의 교육과 훈련에 활용이 되며, 특히 최근에는 의료 분야에서 많이 사용되고 있다. 교육/훈련용 시뮬레이터는 의사가 실제 수술 도구를 이용하여 실제 환자에 대해 처치를 하는 것과 같은 느낌이 나게 하는 촉감/역감 생성 및 영상/음향 출력 하드웨어와 여기에 실감 나는 영상과 촉감을 생성해주는 소프트웨어로 이루어진다. 기존의 시뮬레이터들은 수술 시에 사용되는 다양한 수술 도구들을 모사하기 위해 다양한 형태의 하드웨어들을 사용해야 하므로 복잡하고 비용이 많이 소요되는 문제가 있다. 이 논문에서는 포스 피드백 장치와 변형 가능한 햅틱 컨트롤러를 이용한 치과 수술 시뮬레이션 시스템을 제안한다. 햅틱 하드웨어들은 수술 도구와 수술 부위의 충돌 여부를 파악하고 그에 따른 저항감과 진동감을 제공한다. 특히 길이 변화, 굽힘과 같은 변형이 가능한 햅틱 컨트롤러는 여러 수술 도구들의 형태에 따라 느껴지는 다양한 감각을 표현할 수 있다. 사용자가 햅틱 피드백 장치를 조작하면 햅틱 피드백 장치의 움직임이나 버튼 클릭 등의 이벤트가 시뮬레이션 시스템에 전달되어 치과용 수술 도구와 구강 내부 모델들 사이의 상호작용이 발생하고 이에 따른 햅틱 피드백이 햅틱 피드백 장치로 전달된다. 이러한 기반 기술들을 활용하여 정교한 3차원 모델로 표현된 가상 환경에서 대표적인 치과 수술기법인 매복 사랑니 발치 수술의 현실적인 훈련 경험을 제공한다.

CNN 기반 스펙트로그램을 이용한 자유발화 음성감정인식 (Spontaneous Speech Emotion Recognition Based On Spectrogram With Convolutional Neural Network)

  • 손귀영;권순일
    • 정보처리학회 논문지
    • /
    • 제13권6호
    • /
    • pp.284-290
    • /
    • 2024
  • 음성감정인식(Speech Emotion Recognition, SER)은 사용자의 목소리에서 나타나는 떨림, 어조, 크기 등의 음성 패턴 분석을 통하여 감정 상태를 판단하는 기술이다. 하지만, 기존의 음성 감정인식 연구는 구현된 시나리오를 이용하여 제한된 환경 내에서 숙련된 연기자를 대상으로 기록된 음성인 구현발화를 중심의 연구로 그 결과 또한 높은 성능을 얻을 수 있지만, 이에 반해 자유발화 감정인식은 일상생활에서 통제되지 않는 환경에서 이루어지기 때문에 기존 구현발화보다 현저히 낮은 성능을 보여주고 있다. 본 논문에서는 일상적 자유발화 음성을 활용하여 감정인식을 진행하고, 그 성능을 향상하고자 한다. 성능평가를 위하여 AI Hub에서 제공되는 한국인 자유발화 대화 음성데이터를 사용하였으며, 딥러닝 학습을 위하여 1차원의 음성신호를 시간-주파수가 포함된 2차원의 스펙트로그램(Spectrogram)로 이미지 변환을 진행하였다. 생성된 이미지는 CNN기반 전이학습 신경망 모델인 VGG (Visual Geometry Group) 로 학습하였고, 그 결과 7개 감정(기쁨, 사랑스러움, 화남, 두려움, 슬픔, 중립, 놀람)에 대해서 성인 83.5%, 청소년 73.0%의 감정인식 성능을 확인하였다. 본 연구를 통하여, 기존의 구현발화기반 감정인식 성능과 비교하면, 낮은 성능이지만, 자유발화 감정표현에 대한 정량화할 수 있는 음성적 특징을 규정하기 어려움에도 불구하고, 일상생활에서 이루어진 대화를 기반으로 감정인식을 진행한 점에서 의의를 두고자 한다.

온돌 파이프라인 관리를 위한 초음파 캐비테이션 효과에 대한 실험적 분석 (An Experimental Analysis of Ultrasonic Cavitation Effect on Ondol Pipeline Management)

  • 이웅균
    • 한국건축시공학회지
    • /
    • 제24권1호
    • /
    • pp.67-75
    • /
    • 2024
  • 한국은 주택 난방 방식으로 대부분 온돌 파이프라인을 이용한 방법을 채택하고 있으나 콘크리트 속에 매설되어 있는 특성으로 인해 설치 후 배관 내부의 지속적인 관리를 하기가 쉽지 않다. 온돌 배관은 장기간 사용을 하면 슬러지나 부식 산화물, 미생물 등이 배관 내벽에 퇴적되면서 난방의 효율이 나빠져서 심한 경우에는 열화에 의한 부식, 스케일 등의 문제를 일으키기도 한다. 따라서 본 연구는 온돌 파이프라인의 유지관리를 위하여 초음파 발생 방식을 제안하고 그 가능성을 실험으로 확인하는데 그 목적이 있다. 본 연구를 위한 초음파 발생 장치는 3가지로 제시되며, 표면 진동형, 외부 발생형, 내부 발생형이 그것이다. 관내 오염물은 분말형 가루, 슬러지형 가루, 액상 물질로 선정하였다. 초음파 발생 이후 시간에 따른 세척 효과를 확인하였으며, 세척 결과는 이미지 분석 방법을 통해 산출하였다. 실험 결과, 배관 외부에서 발생시킨 초음파가 효과적임을 알 수 있었으나 배관 내부에서 발생시킨 초음파 역시 유사한 세척 결과를 얻었다. 온돌 배관의 특성 상 외부 발생이 불가능하므로 내부의 발생을 통한 세척 효과가 있을 것으로 기대된다. 향후 배관 내부 발생 장치의 개발을 통해 온돌 파이프라인의 유지관리를 위한 새로운 방식의 제시가 가능할 것으로 기대된다.