• Title/Summary/Keyword: image technology

Search Result 9,453, Processing Time 0.039 seconds

Characteristic of $^{18}F$-FDG Excretion According to Use Diuretics in $^{18}F$-FDG of PET/CT ($^{18}F$-FDG PET/CT 검사에서 이뇨제 사용여부에 따른 $^{18}F$-FDG 배설 특성)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Lee, Sang-Ho;Bae, Jong-Lim;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.151-156
    • /
    • 2012
  • $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG) causes a significant amount of radioactivity retention in kidneys and urinary tract and degrades image quality and diagnostic performance. Diuretics are used to perform tests and prevent the urinary tract retention of $^{18}F$-FDG. The purpose of the study is to investigate how the diuretics affect images and excretion rates of $^{18}F$-FDG. The study consists of a group using diuretics for patients with no primary tumors or transfer lesions in kidneys according to PET/CT images, a group using physiological saline and the control group injecting only $^{18}F$-FDG and SUVs are measured by configuring interested areas for each group. Also, SUVs are compared and evaluated depending on the lasix injection after basic inspection and injecting $^{18}F$-FDG for quantitative analysis. The study shows that images with decreased background radioactivity and increased urine excretion due to using diuretics. However, an opposite result that there is no change in the amount of radioactivity in urine appears. The study concludes that the diuretics may decrease background radioactivity in the images but may not affect the $^{18}F$-FDG excretion.

Automated Functional Morphology Measurement Using Cardiac SPECT Images (SPECT 영상을 사용한 기능적 심근형태의 자동 계측법 개발)

  • Choi, Seok-Yoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • For the examination of nuclear medicine, myocardial scan is a good method to evaluate a hemodynamic importance of coronary heart disease. but, the automatized qualitative measurement is additionally necessary to improve the decoding efficiency. we suggests the creation of cardiac three-dimensional model and model of three-dimensional cardiac thickness as a new measurement. For the experiment, cardiac reduced cross section was obtained from SPECT. Next, the pre-process was performed and image segmentation was fulfilled by level set. for the modeling of left cardiac thickness, it was realized by applying difference equation of two-dimensional laplace equation. As the result of experiment, it was successful to measure internal wall and external wall and three-dimensional modeling was realized by coordinate. and, with laplace formula, it was successful to develop the thickness of cardiac wall. through the three-dimensional model, defects were observed easily and position of lesion was grasped rapidly by the revolution of model. The model which was developed as the support index of decoding will provide decoding information to doctor additionally and reduce the rate of false diagnosis as well as play a great role for diagnosing IHD early.

Evaluation on the Usefulness of Lung Tumor Stereotactic Radiosurgery Applying the CyberKnife $Synchrony^{TM}$ Respiratory Tracking System (사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치를 이용한 폐종양 방사선수술의 유용성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Choi, Jun-Gu;Chae, Hong-In
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.379-386
    • /
    • 2010
  • This study evaluated the motion of tumors during the entire period of therapy and the accuracy of radiosurgery among forty eight lung tumor patients who were underwent radiosurgery using the CyberKnife Synchrony Respiratory Tracking System. The motion of lung tumor was measured by the coordinates of a gold acupuncture needle inserted into the tumor or the area around the tumor using the CyberKnife image guided system. Then the accuracy of radiosurgery was evaluated based on the error of correlation computed with the motion tracking system. The lung tumor motion is Cranio-Caudal direction by an average of $2.63{\pm}1.87\;mm$, moved left-right direction by $1.13{\pm}0.71\;mm$, and anterior-posterior direction by $1.74{\pm}1.16\;mm$. The degree of rotational movement was $1.66{\pm}1.66^{\circ}$ on X axis, $1.20{\pm}0.97^{\circ}$ on Y axis, and $1.18{\pm}0.73^{\circ}$ on Z axis. The vector of translation movement was measured to be $3.78{\pm}2.00\;mm$ on the average. The results show that directions of Cranio-Caudal(p < 0.001), anterior-posterior direction(p < 0.029), and three dimensional vector value(p < 0.002) showed statistical significance, because the lower side of tumor showed more intensive movement compared to the upper side of tumor. The radiosurgery was carried out by compensating the motion of tumor after accurate investigation of the correlation error with the average of $0.95{\pm}0.62\;mm$ during the lung tumor radiosurgery with the CyberKnife Synchrony Respiratory Tracking System.

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.

Comparative Evaluation of Images after Applying Quantum Denoising System Algorithm to Brain Computed Tomography (뇌 컴퓨터단층검사 시 양자잡음제거 알고리즘을 적용한 영상의 비교평가)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.589-594
    • /
    • 2017
  • The objective of this study was to evaluate the enhancement effects of the quantum denoising system (QDS) on brain CT images. This retrospective study was conducted with 45 adults who visited G Radiology located in Gyungbuk for having brain CT tests between Jul 2017 and Oct 2017 after receiving consents. Subjects were divided into a control group (A group; no QDS(-) application during the brain CT test) and a treatment group (B Group; QDS(+) application during the brain CT test). The following conclusions were obtained from the study. The noise values at the Pons part and the Vermis part were significantly (p<0.05) lower in B Group ($Pons=5.41{\pm}1.05HU$; $Vermis=5.28{\pm}0.73HU$) than A Group ($Pons=6.92{\pm}0.98HU$; Vermis=6.72). The SNR values at the Pons part and the Vermis part were significantly (p<0.05) higher in B Group ($Pons=7.28{\pm}2.56$; $Vermis=8.63{\pm}3.04$) than A Group ($Pons=5.21{\pm}1.28$; $Vermis=6.23{\pm}1.49$). In conclusion, the results of this study suggested that the application of QDS to the brain CT test would enhance the signal to noise ratio (SNR) and the contrast to noise ratio (CNR) to provide an image more appropriate for diagnosis.

Development of Functional Hanji Added Citrus Peel(I) - Hanji added Korean citrus peel - (감귤박을 첨가한 기능성 한지제조 기술개발(제1보) - 한국산 감귤박 첨가 한지 -)

  • Kim, Hae-Gong;Lim, Hyun-A;Kim, So-Young;Kang, Sool-Saeng;Lee, Hyo-Yeon;Yun, Pil-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.1 s.119
    • /
    • pp.38-47
    • /
    • 2007
  • This study was carried out to develop a new application field and obtain the basic data of citrus peel as waste in Jeju island and traditional Hanji for producing functional Hanji. The results measuring physical and optical properties, water vapor permeance and antibacterial activity are as follows. It was revealed that apparent density go as down but bulk raise up in the structural view of Hanji with increasing of the addition various Korean citrus peel (citrus unshiu, cheonggyun and hanrabong peel, and citrus unshiu peel powder) percentages, and that the density of Hanji added citrus unshiu peel was higher, but bulk was lower in compared with Hanji added other kinds of peel. Those Hanji added citrus unshiu peel, cheonggyun peel, hanrabong peel and citrus unshiu powder were very great not only in the strength (breaking length, burst index, tear index and folding endurance) but also in water vapor permeant rate in comparison with Hanji. The pHs of Hanji were neutrality (7 to 8). The brightness of the Hanji added various citrus peel percentages was low in compared to Hanji, and the 40% addition of hanrabong peel was the lowest. When 40% hanrabong peel was added to Hanji, it was very yellow in the color degree. When cheonggyun peel was added to Hanji manufacture, water vapor permeant rate was highly effective. It is known that vacant space of intrafiber was reduced by image analysis of Hanji and the additions of peel of citrus unshiu, cheonggyun and hanrabong were distributed equally in the interior of Hanji. The antibacterial activity of Hanji added citrus unshiu peel is more than 98%. After all, it would be able to increase utilization of Hanji, extensively. Namely, production of high quality Hanji added functional materials is expected for new valuable industry of citrus peel and Hanji.

Chitosan Silver Nano Composites (CAgNCs) as Antibacterial Agent Against Fish Pathogenic Edwardsiella tarda (어류 병원성 균주 Edwardsiella tarda에 대한 키토산-실버 나노입자의 항박테리아 효과)

  • Dananjaya, S.H.S.;Godahewa, G.I.;Lee, Youngdeuk;Cho, Jongki;Lee, Jehee;De Zoysa, Mahanama
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.502-506
    • /
    • 2014
  • Recently nano particles have proven for wide array of bioactive properties. In the present study, antibacterial properties of chitosan silver nano composites (CAgNCs) were investigated against fish pathogenic Edwardsiella tarda. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of CAgNCs against E. tarda were $25{\mu}g/mL$ and $125{\mu}g/mL$, respectively. The field emission scanning electron microscope (FE-SEM) image of CAgNCs treated E. tarda showed the strongly damaged bacteria cells than non-treated bacteria. Furthermore, treatment of CAgNCs induced the level of intracellular reactive oxygen species (ROS) in E. tarda cells in concentration and time dependent manner suggesting that it may generate oxidative stress leading to bacterial cell death. In addition, MTT assay results showed that the lowest cell viability at $100{\mu}g/mL$ of CAgNCs treated E. tarda. Overall results of this study suggest that CAgNCs is a potential antibacterial agent to control pathogenic bacteria.

A Comparative Analysis for the Digitizing Accuracy by Satellite Images for Efficient Shoreline Extraction (효율적인 해안선 추출을 위한 위성영상별 디지타이징 정확도 비교 분석)

  • Kim, Dong-Hyun;Park, Ju-Sung;Jo, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.1
    • /
    • pp.147-155
    • /
    • 2015
  • The existing field survey and aerial photography involve the waste of manpower and economic loss in the coastline survey. To minimize these disadvantages, the digitization for efficient coastline extraction was conducted in this study using the points extracted from the standard coastline of the approximate highest high water and the diverse satellite images (KOMPSAT-3, SPOT-5, Landsat-8 and Quickbird-2), and the comparative accuracy analysis was conducted. The differences between the standard coastline points of the approximate highest high water and the coastline of each satellite were smallest for KOMPSAT-3, followed by Quickbird-2, SPOT-5 and Landsat-8. The significant probability from between the multipurpose applications satellite and Quickbird-2 (significant probability two-tailed) was statistically significant at 1% significance level. Therefore, high-resolution satellite images are required to efficiently extract the coastline, and KOMPSAT-3, from which images are easily acquired at a low cost, will enable the most efficient coastline extraction without external support.

Humanity in the Posthuman Era : Aesthetic authenticity (포스트휴먼시대의 인간다움 : 심미적 진정성)

  • Ryu, Do-hyang
    • Journal of Korean Philosophical Society
    • /
    • v.145
    • /
    • pp.45-69
    • /
    • 2018
  • This is an attempt to reflect on humanity in the post-human era. Here, I think that the question of future human beings should be critically raised in the following two meanings. First, can post-humans recover the body, emotions, nature and women's voices suppressed by modern enlightened subjects? Second, can post-humans preserve humanity by fighting inhumanity without presupposing human essence or immutable foundations? In answer to these questions, I will have a dialogue with M. Heidegger(1889-1976), W. Benjamin(1892-1940), Th. W Adorno(1903-1969). The three philosophers looked at the inhuman world situation brought about by modern subjects and technology, and found the possibility of new human beings. The three philosophers' new human image are the three possible models of post-humanism, 'a human being as ek-sistence' (Heidegger, Chapter 2), 'the man who restored the similarity with the other through innervation' (Benjamin, Chapter 3), 'A human being who negates the inhuman society' (Adorno, Chapter 4), and examines the current status of each. In conclusion, as long as the fourth industrial revolution is developed as a system of digital capitalism that controls the world as a whole from human senses, impulses, and unconsciousness, the necessity of the post-human era is aesthetic authenticity.

The Study on the Fashion Style of Female Celebrities in Seoul Fashion Week (서울 패션 위크에 나타난 여성 셀러브리티 패션 스타일에 관한 연구)

  • Lee, Ji-Yeon;Kim, Jang-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.284-295
    • /
    • 2019
  • Celebrities form a dominant culture of one era and are cultivating influence to lead new fashion. Domestic women celebrities attending Seoul Fashion Week build their image as a fashion leader by exposing their own fashion aesthetics to the public. This promotes PR and sales of the brand of fashion designers in the collection. This study considers the fashion trends of women celebrities by analyzing the fashion style of women celebrities in Seoul Collection over the recent five years. The results of this study on contents analysis are as follows. First, straight silhouettes, achromatic colors, and an absence of a pattern or decoration comprised a high proportion. Celebrities preferred a modern and minimal style. Second, they preferred a feminine style that shows traditional feminine beauty through slim and princess silhouettes, one-piece dress or skirts, soft materials, and decorations with ruffles. In addition, as a matching jacket on one-piece dresses also appeared, it showed that celebrities attempted to change the chic feminine style with masculine beauty. Third, boxy silhouettes, multi-color mixed with colorful colors, graphic or lettering patterns, glittering materials and lots of details comprised a high proportion. This means celebrities pursue a maximal style that reveals their strong presence as fashion leaders.