A Novel Image Probing System for Precise Quantification of Angiogenesis

  • Ejaz, Sohail;Chekarova, Irina;Lim, Chae-Woong
    • 한국수의병리학회:학술대회논문집
    • /
    • 한국수의병리학회 2005년도 Proceedings of The 2nd Asian Society of Veterinary Pathology Symposium(Vol.2) and 2005 Annual Meeting of The Korean Society of Veterinary Pathology(Vol.9)
    • /
    • pp.62.1-63
    • /
    • 2005
  • PDF

Probing of Concrete Specimens using Ground Penetration Radar

  • Rhim, HongChul
    • Corrosion Science and Technology
    • /
    • 제3권6호
    • /
    • pp.262-264
    • /
    • 2004
  • Ground Penetrating Radar (GPR) has been used to image inside concrete specimens embedded with steel bars and delamination. An imaging algorithm has been developed to improve measurement output generated from a commercial radar system. For the experiments, laboratory size concrete specimens are made with the dimensions of $1,000mm(W){\times}1,000mm(L){\times}250mm(D)$. The results have shown improved output of the radar measurements compared to commercially available processing methods.

물리탐사에 기초한 대수층 특성화 및 적용 사례 분석 (Aquifer Characterization Based on Geophysical Methods and Application Analysis on Past Cases)

  • 정주연;김빛나래;송서영;정인석;송성호;남명진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권2호
    • /
    • pp.1-23
    • /
    • 2022
  • For its essential importance as a resource, sustainable development of groundwater has been major research interests for many decades. Conventional characterization of aquifer and groundwater has relied on borehole data from observation well. Although borehole data provide useful information on yield and flow of groundwater, it is often difficult and sometimes costly to estimate the spatial distribution of groundwater in entire aquifer. Geophysical probing is an alternative techique that provides such information due to its capability to image subsurface structures as well as to delineate spatial distribution of hydraulic parameters. This study presents various technical information about geophysical probing to estimate main characteristics of aquifer for groundwater exploitation. Subsequently, we analyzed representative cases, in which geophysical methods were applied to identify the location of the groundwater, classify freshwater and brine, derive hydraulic constants, and monitor groundwater.

Improved accuracy in periodontal pocket depth measurement using optical coherence tomography

  • Kim, Sul-Hee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Jun-Min;Yi, Won-Jin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제47권1호
    • /
    • pp.13-19
    • /
    • 2017
  • Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was $3.10{\pm}0.15mm$, $4.11{\pm}0.17mm$, $5.09{\pm}0.17mm$, and $6.05{\pm}0.21mm$ for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

포톤 탐사법을 이용한 개선된 점진적 포톤 매핑 (Improved Progressive Photon Mapping Using Photon Probing)

  • 이상길;신병석
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제16권3호
    • /
    • pp.41-48
    • /
    • 2010
  • 포톤 매핑은 대표적인 전역 조명 방법으로써 광원에서 많은 수의 포톤을 방출하여 이를 이용해 사실적인 렌더링을 수행한다. 하지만 매우 많은 수의 포톤을 추적하기 때문에 실시간 렌더링이 힘들고 많은 양의 메모리를 사용하는 문제가 있다. 이러한 문제를 개선한 방법이 점진적 포톤 매핑이다. 기존의 점진적 포톤 매핑은 먼저 광선 추적법을 통해 각 광선과 물체와의 충돌 위치를 찾는다. 다음으로 포톤 추적 단계에서는 반복적으로 적은 수의 포톤을 방출하고, 충돌 위치를 중심으로 하며 고정된 반지름을 가지는 구 안에 들어오는 포톤으로 포톤의 밝기를 누적한다. 이 방법은 포톤 매핑보다 자원을 적게 소모하지만, 방출된 포톤이 임의의 방향으로 진행하기 때문에 충분한 포톤을 확보하고 부드러운 영상을 렌더링하기 위해 많은 시간이 필요하다. 이를 보완하기 위해 본 논문에서는 포톤 탐사 단계를 추가하여 구 안에 들어오는 포톤들의 분포를 계산하고 그에 따라 구의 반지름을 조절하는 방법을 제안한다. 또한 래디언스 추정 과정에 콘 필터를 적용하여 영상을 선명히 렌더링한다.

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

스펙클 포토그라피와 화상처리(畵像處理)에 의(依)한 면내변위(面內變位) 계측(計測) (Measurement of In- plane Displacement by Speckle Photography and Image Processing)

  • 한응교;각설지조;김경석
    • 비파괴검사학회지
    • /
    • 제6권2호
    • /
    • pp.37-45
    • /
    • 1987
  • Speckle photography is a very useful method for measuring in-plane surface displacement. In its basic form, the object to be studied is illuminated with a divergent laser beam, and a double exposure photograph of the object is recorded, on a fine-grain film or plate, before and after the object is deformed, The magnitude and the direction of the displacement can then be obtained by measuring the spacing and the direction of the Young's fringe, which is produced by probing the developed negative with an unexpaned laser beam, and consists of a pattern of parallel equi-spaced dark bands. In this paper, a hybrid optical and electronic image processing is described-Young's fringe on the viewing screen is observed by a TV-camera and the 2-D video signal is converted from analog to digital and transfered to the computer where the spacing and direction of the fringes are calculated. Several examples of application show that the displacement magnitude and direction can be determined with an accuracy of $0.1{\mu}m\;and\;0.1^{\circ}$ respectively.

  • PDF

Maskless Lithography system을 이용한 TSP 검사 용 micro bump 제작에 관한 연구. (A study of fabrication micro bump for TSP testing using maskless lithography system.)

  • 김기범;한봉석;양지경;한유진;강동성;이인철
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.674-680
    • /
    • 2017
  • 본 논문은 현재 개인 휴대기기 및 대형 디스플레이 장비의 제어에서 폭넓게 사용되고 있는 터치스크린 패널 (TSP; Touch Screen Panel)의 정상 작동 유무를 확인하기 위한 micro bump 제작 기술에 관한 연구이다. 터치스크린 패널은 감압식, 정전식 등의 여러 가지 방식이 있으나 지금은 편리성에 의하여 정전식 방식이 주도하고 있다. 정전식의 경우 해당하는 좌표의 접촉에 따라 전기적 신호가 변화하게 되고, 이를 통하여 접촉 위치를 확인할 수 있으며 따라서 접촉 위치에 따른 전기 특성 검사가 필수적이다. 검사공정에서 TSP의 모델이 변경됨에 따라 새로운 micro bump를 제작이 및 검사 프로그램의 수정이 필수적이다. 본 논문에서는 새로운 micro bump 제작 시 mask를 사용하지 않아 보다 경제적이며 변화에 대응이 유연한 maskless lithography 시스템을 이용하여 micro bump 제작 가능성에 대하여 확인하였다. 이를 위하여 제작되는 bump의 pitch에 따른 전기장 간섭 시뮬레이션을 진행하였으며, maskless lithogrphy 공정을 적용하기 위한 패턴 이미지를 생성하였다. 이후 MEMS 기술에 해당하는 PR(Photo Resist) 패터닝 공정에서 노광(Lithography) 공정 및 현상(Developing) 공정을 통하여 PR 마스크를 제작한 후 electro-plating 공정을 통하여 micro bump를 제작하였다.

Polarity Probing Two-Photon Fluorophores Based on [2.2]Paracyclophane

  • Woo, Han-Young;Korystov, Dmitry;Jin, Young-Eup;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2253-2260
    • /
    • 2007
  • A series of tetra donor substituted [2.2]paracyclophane-based two-photon absorption (TPA) fluorophores were synthesized in neutral and cationic forms. The imaging activity of overall set of fluorophores was studied by the two-photon induced fluorescence (TPIF) method in a range of solvents. We also measured a clear progression toward a longer photoluminescence lifetime with increasing solvent polarity (intrinsic photoluminescence lifetime, τi: ~2 ns in toluene → 12-16 ns in water). The paracyclophane fluorophores with this unique property can be utilized as an optical polarity probe for the biomolecular substrates. The combined measurement of the two-photon fluorescence microscopy (TPM) cell image and TPIF lifetime can give us a better understanding of the biological processes and local environments in the cells.