• Title/Summary/Keyword: image center

Search Result 4,248, Processing Time 0.045 seconds

Subjective Imaging Effect Assessment for Intelligent Imaging Terminal Design: a Method for Engineering Site

  • Liu, Haoting;Lv, Ming;Yu, Weiqun;Guo, Zhenhui;Li, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권3호
    • /
    • pp.1043-1064
    • /
    • 2020
  • A kind of Subjective Imaging Effect Assessment (SIEA) method and its applications on intelligent imaging terminal design in engineering site are presented. First, some visual assessment indices are used to characterize the imaging effect: the image brightness, the image brightness uniformity, the color image contrast, the image edge blur, the image color difference, the image saturation, the image noise, and the integrated imaging effect index. A linear weighted function is employed to carry out the SIEA computation and the Analytic Hierarchy Process (AHP) technique is used to estimate its weights. Second, a SIEA software is developed. It can play images after the settings of assessment index or assessment reaction time, etc. Third, two cases are used to illustrate the application effects of proposed method: the image enhancement system design for surveillance camera and the imaging environment perception system design for intelligent lighting terminal. A Prior Sequential Stimulus (PSS) experiment is proposed to improve the evaluation stability of SIEA method. Many experiment results have shown the proposed method can realize a stable system design or parameters setting for the intelligent imaging terminal in engineering site.

CCD Camera 기반 실시간 방사선치료조사면 검증 시스템 개발 및 화질개선을 위한 기초연구 (System Development and Fundamental Study of CCD Camera Based Electronic Portal Imaging Device)

  • 장기원;박지군;이동길;김진영;남상희;하성환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.380-383
    • /
    • 2003
  • The purpose of this study is to develope prototype EPID system and improve image quality of radiation therapy field imaging system using CCD camera. For this research we used Linac(Clinac 4/100), Copper metal plate, $Gd_2O_2S_2$ phosphor and CCD camera(Photronic). In this study we find best thickness of buil-up metal plate and acquired projection image of humanoid head phantom. Also we enhanced raw image data using superposition and histogram stretching method. Through the thickness optimized of metal plate and image processing, we confirmed of an improved image quality of an EPID system using CCD camera. As result, highest quality image was acquired at 1mm thickness of Copper metal plate and improved image quality by image processing methods.

  • PDF

Histogram을 이용한 적응형 내시경 Image Enhancer의 개발 (Development of Adaptive Endoscope Image Enhancer Using Histogram)

  • 이상학;김정훈;송철규;이영묵;김원기;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.345-348
    • /
    • 1997
  • Endoscope image is the shape that a doctor sees inside of patient through endoscope. The characteristics of these images are much effected by the light source of endoscope, specially areas in short distance from a light have much light source and look clear, but areas in long distance from a light look dark relatively because of little light quantity. So we developed a new level adaptive image enhancer for the dark area in a endoscope image. The algorithm we made consists of three parts ; 1) Classification of histogram in segmented area 2) Smoothing and Adaptive Histogram Equalization 3) Adaptive Histogram Modification.

  • PDF

The optimization of new alignment films in the TNLC for low image-sticking

  • Lee, Jong-Hyun;Yi, Jun-Sin;Jung, Hwan-Kyung;Lee, Seung-Guk;Nam, Hyo-Hak;Nam, Yoon-Joung;Choi, Sung-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.513-516
    • /
    • 2007
  • We introduce a new copolymer alignment film made by bridge-building structure. It is a better film to decrease the image-sticking level in LCD displays. It is noted that the image-sticking was decreased by preventing ion mixing between inter-layers through high hardness. We have investigated the electrical characteristics such as pretilt angle, Residual DC, VHR by changing cure temperature and process delay time conditions of the new alignment film. In this paper, we have investigated the solution for the deep-rooted image defect and incidentally got a contrast ratio improvement by high anchoring force and hardness elevation through the new copolymer alignment film.

  • PDF

Correlation analysis between rotation parameters and attitude parameters in simulated satellite image

  • Yun, Young-Bo;Park, Jeong-Ho;Yoon, Geun-Won;Park, Jong-Hyun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.553-558
    • /
    • 2002
  • Physical sensor model in pushbroom satellite images can be made from sensor modeling by rotation parameters and attitude parameters on the satellite track. These parameters are determined by the information obtained from GPS, INS, or star tracker. Provided from satellite image, an auxiliary data error is connected directly with an error of rotation parameters and attitude parameters. This paper analyzed how obtaining satellite images influenced errors of rotation parameters and attitude parameters. furthermore, for detailed analysis, this paper generated simulated satellite image, which was changed variously by rotation parameters and attitude parameters of satellite sensor model. Simulated satellite image is generated by using high-resolution digital aerial image and DEM (Digital Elevation Model) data. Moreover, this paper determined correlation of rotation parameter and attitude parameters through error analysis of simulated satellite image that was generated by various rotation parameters and attitude parameters.

  • PDF

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

A Study for the Adaptive wavelet-based Image Merging method

  • Kim, Kwang-Yong;Yoon, Chang-Rak;Kim, Kyung-Ok
    • 대한공간정보학회지
    • /
    • 제10권5호
    • /
    • pp.45-51
    • /
    • 2002
  • The goal of image merging techniques are to enhance the resolution of low-resolution images using the detail information of the high-resolution images. Among the several image merging methods, wavelet-based image merging techniques have the advantages of efficient decorrelation of image bands and time-scale analysis. However, they have no regard for spatial information between the bands. In other words, multiresolution data merging methods merge the same information-the detail information of panchromatic image-with other band images, without considering specific characteristics. Therefore, a merged image contains much unnecessary information. In this paper, we discussed this 'mixing' effect and, proposed a method to classify the detail information of the panchromatic image according to the spatial and spectral characteristics, and to minimize distortion of the merged image.

  • PDF

주택문화관의 브랜드 이미지 요소에 관한 연구 (A Study on The Brand Image Elements of Housing Cultural Center)

  • 김정윤;이현수
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2007년도 추계학술발표대회 논문집
    • /
    • pp.26-29
    • /
    • 2007
  • By changing housing market, housing cultural center furnishes information, value added, image of housing. For publicity their unique house, construction companies provide not only concrete and substantial material but also sensible and capacity service through the community space of housing cultural center. The consumer's experience of housing cultural center have an effect on purchase power apartment. The image of enterprise is important to select commodities to consumers. Though main clients are women, housing cultural center has not space concept and aim to concern for them. According to begin women a group of consumers, they have purchasing power in family. Apartment is no exception. Housing cultural center is used as continuous culture space that provide various experiential chance for consumer, especially women by systematize and distinct design detail and feature component. Accordingly, the purpose of this study is an analysis about community space of housing cultural center with the woman marketing based on experience.

  • PDF

Affine-Invariant Image normalization for Log-Polar Images using Momentums

  • Son, Young-Ho;You, Bum-Jae;Oh, Sang-Rok;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1140-1145
    • /
    • 2003
  • Image normalization is one of the important areas in pattern recognition. Also, log-polar images are useful in the sense that their image data size is reduced dramatically comparing with conventional images and it is possible to develop faster pattern recognition algorithms. Especially, the log-polar image is very similar with the structure of human eyes. However, there are almost no researches on pattern recognition using the log-polar images while a number of researches on visual tracking have been executed. We propose an image normalization technique of log-polar images using momentums applicable for affine-invariant pattern recognition. We handle basic distortions of an image including translation, rotation, scaling, and skew of a log-polar image. The algorithm is experimented in a PC-based real-time vision system successfully.

  • PDF

양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법 (Automated patient set-up using intensity based image registration in proton therapy)

  • 장훈;김호식;최승오;김은숙;정종휘;안상희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.97-105
    • /
    • 2018
  • 목 적 : Proton Therapy는 Bragg-peak를 이용해 종양에는 최대의 선량, 정상조직에는 최소의 선량을 줄 수 있는 특징을 가지고 있기 때문에 환자의 위치변화나 치료부위의 위치 변화를 정량화 할 수 있는 의료영상 분석 시스템은 양성자 치료에 있어서 무엇보다도 중요하다. 본 연구 목적은 Matlab 기반의 In-house Registration code를 제작하여 기존 DIPS program을 통한 Set-up과 In-house code를 통한 영상정합을 비교하여 Algorithm의 유용성을 평가하고 DIPS와 DRR간의 오차 값을 확인하여 기존 치료의 정확성을 평가하고자 한다. 대상 및 방법 : 본원에서 양성자 치료를 받은 13명의 뇌종양, 두경부암 환자를 대상으로 하였으며 영상비교에 필요한 DIPS Program System(Version 2.4.3, IBA, Belgium)와 환자의 치료계획을 위해 Eclipse Proton Planning System(Version 13.7, Varian, USA)을 사용하였다. Registration 방법에 대한 Validation을 위해 Test image를 인위적으로 회전 및 이동하여 기존 Image와 영상정합 하였고, 기존 Set up 방식의 DIPS program의 환자 일별 초기 Set up image를 plan DRR과 영상정합 하여 각각 오차 값을 얻어 Algorithm의 유용성을 평가하였다. 그리고 기존 Set up 방식의 정확성을 평가하기 위해 환자 일별 최종 Set up image와 DRR image를 영상정합하여 오차 값을 확인하였다. 결 과 : Test image를 left와 right 방향으로 각각 0.5, 1, 10 cm를 이동시켰을 때 평균 0.018 cm의 오차 값을 보였으며 시계와 반시계방향으로 각각 1, $10^{\circ}$씩 회전시켰을 경우에는 평균 $0.0011^{\circ}$의 오차를 나타냈다. 4명의 환자 일별 초기 image를 영상정합 하였을 때는 x, y, z 방향 순으로 평균 0.056, 0.044, 0.053 cm의 오차 값을 나타냈으며 Rotation, Pitch 순으로 0.190, $0.206^{\circ}$의 차이를 나타냈다. 13명의 환자 일별 최종 image를 영상 정합 하였을 때는 x, y, z 방향 순으로 평균 차이는 0.062, 0.085, 0.074 cm이였고 Vector 값으로는 평균 0.120 cm의 차이를 보였다. Rotation, Pitch 순으로는 평균 0.171, $0.174^{\circ}$의 차이 값을 나타냈다. 결 론 : 본 연구를 통해 제작된 Matlab 기반의 In-house Registration code는 단순한 Image 뿐만 아니라 해부학적 구조에서도 Intensity 기반의 정확한 영상정합을 나타냈다. 또한 기존 치료방식의 DIPS program을 통한 Set-up 오차는 매우 미미한 차이를 보임으로써 이는 양성자치료의 정확성을 확인할 수 있었다. 앞으로 임상적용을 위해 추가적인 프로그램 개발과 향후 Intensity 기반의 Matlab In-house code 연구가 필요하다고 사료된다.

  • PDF