• Title/Summary/Keyword: image assessment

Search Result 1,139, Processing Time 0.026 seconds

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.

Principles of Intraoperative Neurophysiological Monitoring with Insertion and Removal of Electrodes (수술 중 신경계감시검사에서 검사에 따른 전극의 삽입 및 제거방법)

  • Lim, Sung Hyuk;Park, Soon Bu;Moon, Dae Young;Kim, Jong Sik;Choi, Young Doo;Park, Sang Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.453-461
    • /
    • 2019
  • Intraoperative neurophysiological monitoring (INM) examination identifies the damage caused to the nervous system during surgery. This method is applied in various surgeries to validate the procedure being performed, and proceed with confidence. The assessment is conducted in an operating room, using subdermal needle electrodes to optimize the examination. There are no textbooks or guides for the correct stimuli and recording areas for the surgical laboratory test. This article provides a detailed description of the correct stimuli and recording parts in motor evoked potential (MEP), somatosensory evoked potential (SSEP), brainstem auditory evoked potentials (BAEP) and visual evoked potentials (VEP). Free-running Electromyography (EMG) is an observation of the EMG that occurs in the muscle, wherein the functional state of most cranial nerves and spinal nerve roots is determined. In order to help understand the test, an image depicting the inserting subdermal needle electrodes into each of the muscles, is attached. Furthermore, considering both the patient and the examiner, a safe method is suggested for removal of electrodes after conclusion of the test.

Detection of Artificial Displacement of a Reflector by using GB-SAR Interferometry and Atmospheric Humidity Correction (GB-SAR 간섭기법을 이용한 반사체의 인위적 변위탐지 및 대기습도보정)

  • Lee, Jae-Hee;Lee, Hoon-Yol;Cho, Seong-Jun;Sung, Nak-Hun;Kim, Jung-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.123-131
    • /
    • 2010
  • In this paper we applied Ground-Based Synthetic Aperture Radar(GB-SAR) interferometry to detect artificial displacement of a reflector and performed an atmospheric humidity correction to improve the accuracy. A series of GB-SAR images were obtained using a center frequency of 5.3 GHz with a range resolution of 25 cm and a azimuth resolution of $0.324^{\circ}$, all in full-polarization (HH, VV, VH, HV) modes. A triangular trihedral corner reflector was located 160 m away from the system, and the artificial displacements of 0-40 mm was implemented during the GB-SAR image acquisition. The result showed that the RMS error between the actual and measured displacements, averaged in all polarization data, was 1.22 mm, while the maximum error in case of the 40 mm displacement was 2.72 mm at HH-polarization. After the atmospheric correction with respect to the humidity, the RMS error was reduced to 0.52 mm. We conclude that a GB-SAR system can be used to monitor the possible displacement of artificial/natural scatterers and the stability assessment with sub-millimeter accuracy.

A Study on the Morphological Analysis of Sperm (정자의 형태학적 특성 분석에 관한 연구)

  • Paick, Jae-Seung;Jeon, Seong-Soo;Kim, Soo-Woong;Yi, Won-Jin;Park, Kwang-Suk
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.2
    • /
    • pp.153-165
    • /
    • 1997
  • In male reproducible health, fertility and IVF (in-vitro fertilization), semen analysis has been most important. Semen analysis can be divided into concentration, motional and morphological analysis of sperm. The existing method which was developed earlier to analyze semen concentrated on the sperm motility analysis. To provide more useful and precise solutions for clinical problems such as infertility, semen analysis must include sperm morphological analysis. But the traditional tools for semen analysis are subjective, imprecise, inaccurate, difficult to standardize, and difficult to reproduce. Therefore, with the help of development of microcomputers and image processing techniques, we developed a new sperm morphology analyzer to overcome these problems. In this study the agreement on percent normal morphology was studied between different observers and a computerized sperm morphology analyzer on a slide-by-slide basis using strict criteria. Slides from 30 different patients from the SNUH andrology laboratory were selected randomly. Microscopic fields and sperm cells were chosen randomly and percent normal morphology was recorded. The ability of sperm morphology analyzer to repeat the same reading for normal and abnormal cells was studied. The results showed that there was no significant bias between two experienced observers. The limits of agreement were 4.1%${\sim}$-3.8%. The Pearson correlation coefficient between readers was 0.79. Between the manual and sperm morphology analyzer, the same findings were reported. In this experiments the slides were stained by two different methods, PAP and Diff-Quik staining methods. The limits of agreement were 7.2%${\sim}$-5.7% and 6.0%${\sim}$-6.3%, respectively. The Pearson correlation coefficients ware 0.76 and 0.91, respectively. The limits of agreement was tighter below 20% normal forms. In the experiments of repeatability, 52 cells stained by PAP and Diff-Quik staining methods were analyzed three times in succession. Estimating pairwise agreement, the kappa statistic for the pairs were 0.76, 0.81, 0.86, and 0.75, 0.88, 0.88 respectively. In this study it was shown that there was good agreement between manual and computerized assessment of normal and abnormal cells. The repeatability and agreement per slide of computerized sperm morphology analyzer was excellent. The computer's ability to classify normal morphology per slide is promising. Based on results obtained, this system can be of clinical value both in andrology laboratories and IVF units.

  • PDF

Accuracy of Automatic Cephalometric Analysis Programs on Lateral Cephalograms of Preadolescent Children (소아 환자 대상의 자동 계측점 식별 프로그램의 정확성 평가)

  • Song, Min Sun;Kim, Seong-Oh;Kim, Ik-Hwan;Kang, Chung-min;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.245-254
    • /
    • 2021
  • The aim of this study was to evaluate the accuracy of 3 different automatic landmark identification programs on lateral cephalgrams and the clinical acceptability in pediatric dentistry. Sixty digital cephalometric radiographs of 7 to 12 years old healthy children were randomly selected. Fourteen landmarks were chosen for assessment and the mean of 3 measurements of each landmark by a single examiner was defined as the baseline landmarks. The mean difference between an automatically identified landmark and the baseline landmark was measured for each landmark on each image. The total mean difference of 3 automatic programs compared to the baseline landmarks were 2.53 ± 1.63 mm. Errors among 3 programs were not significantly different for 12 of 14 landmarks except Orbitale and Gonion. The automatic landmark identification programs showed significant higher mean detection errors than the manual method. The programs couldn't be used as the 1st tool to replace human examiners. But considering short consuming time, these results indicate that all 3 programs have sufficient validity to be used in pediatric dental clinic.

A Legal Review of Personal Information Protection for Invigorating Online Targeted Advertising: Focusing on the Concept of Personal Information (온라인 맞춤형 광고 활성화를 위한 개인 정보 보호에 대한 법적 고찰: '개인 정보'의 개념을 중심으로)

  • Cho, Jae-Yung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.492-497
    • /
    • 2019
  • This study analysed the legal concept of personal information(PI), which was not differentiated from behavioral information, and established it clearly for invigorating online targeted advertising(OTA), which draw attention in big data era; by selecting Guidelines of Assessment of Data Breach Incident Factors and Guidelines of Measures for No-Identifying Personal Information based on Personal Information Protection Act(PIPA) and Enforcement Decree of the PIPA. As a result, PI was defined as any kind of information relating to (1)a living individual(not group, corporate body or things etc.); (2)makes possibly identify the individual by his or her identifiers such as name, resident registration number, image, etc. (not included if not identify the individual); and (3)including information like attribute values which makes possibly identify any specific individual, if not by itself, but combined with other information which can be actually collected and combined). Specifically, PI includes basic, proper distinguishable, sensitive and other PI. It is suggested that PI concept should be researched continually with digital technology development; the effectiveness of the Guidelines of PI Protection in OTA, the legal principles of PI protection from not only users' but business operators' perspectives and the differentiation between PI and behavioral information in OTA should be researched.

Accuracy Analysis of Low-cost UAV Photogrammetry for Corridor Mapping (선형 대상지에 대한 저가의 무인항공기 사진측량 정확도 평가)

  • Oh, Jae Hong;Jang, Yeong Jae;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.565-572
    • /
    • 2018
  • Recently, UAVs (Unmanned Aerial Vehicles) or drones have gained popularity for the engineering surveying and mapping because they enable the rapid data acquisition and processing as well as their operation cost is low. The applicable fields become much wider including the topographic monitoring, agriculture, and forestry. It is reported that the high geospatial accuracy is achievable with the drone photogrammetry for many applications. However most studies reported the best achievable mapping results using well-distributed ground control points though some studies investigated the impact of control points on the accuracy. In this study, we focused on the drone mapping of corridors such as roads and pipelines. The distribution and the number of control points along the corridor were diversified for the accuracy assessment. In addition, the effects of the camera self-calibration and the number of the image strips were also studied. The experimental results showed that the biased distribution of ground control points has more negative impact on the accuracy compared to the density of points. The prior camera calibration was favored than the on-the-fly self-calibration that may produce poor positional accuracy for the case of less or biased control points. In addition, increasing the number of strips along the corridor was not helpful to increase the positional accuracy.

Test and Evaluation for GNSS based Lane Level Precise Positioning User System (위성항법 기반 차로구분 정밀위치결정 사용자 시스템 시험 평가)

  • Lee, Jung-Hoon;Lee, Sangwoo;Ahn, Jongsun;Im, Sunghyuck;Choi, Yunseong;Jang, Youngsu;Lee, Dongchul;Heo, Moon-Beom
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.566-576
    • /
    • 2018
  • The C-ITS requires the lane level positioning of the vehicle in the land transportation environment, and it is most effective to utilize the GNSS. In the precision positioning system based on satellite navigation, the evaluation of dynamic environment of lane level positioning performance should be accompanied and the evaluation system configuration should be preceded. In this paper, we selected performance indicators, assessment equipment, and reliability of reference equipment for evaluation of precision positioning user systems based on the GNSS. The performance evaluation system described above is applied to a real system, and the performance evaluation tool developed for the evaluation system is described. The numerical performance evaluation was carried out based on the data collected by carrying out the actual testbed driving. The performance evaluation by the actual driving trajectory and driving image comparison was performed to derive and analyse the evaluation results of the vehicle lane level positioning user system.

DENTAL TREATMENT IN A PATIENT WITH ATYPICAL TERATOID RHABDOIDAL TUMOR UNDER GENERAL ANESTHESIA (비정형 유기형/간상 종양(Atypical teratoid rhabdoidal tumor) 환자의 전신마취 하 치과치료)

  • Kim, Hyuntae;Song, Ji-Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Shin, Teo Jeon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.74-78
    • /
    • 2019
  • Atypical teratoid rhabdoidal tumor(AT/RT) is a rare and fast-growing tumor usually diagnosed in childhood. Routine magnetic resonance imaging(MRI) assessment of AT/RT patients is done to detect metastatic tumors and recurrent lesions. The purpose of this case report is to present a case about caries treatment of a 3-year-8-month old female patient with AT/RT under general anesthesia. A 3-year-8-month old patient with AT/RT visited Seoul National University Dental Hospital for caries treatment. At the first dental visit, she was receiving chemotherapy. Multiple caries were observed from clinical and radiographic examination. The dental procedure was successfully performed under general anesthesia. Patients with brain tumor may take routine MRI to detect metastatic tumors and recurrent lesions. Dentists should take into consideration of possible dislodgement of restoration by ferromagnetic properties and artifact formation on MRI image. Ready-made zirconia crowns can be a good restoration option for such patients.

The Role of Double Inversion Recovery Imaging in Acute Ischemic Stroke

  • Choi, Na Young;Park, Soonchan;Lee, Chung Min;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.210-219
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate if double inversion recovery (DIR) imaging can have a role in the evaluation of brain ischemia, compared with diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) imaging. Materials and Methods: Sixty-seven patients within 48 hours of onset, underwent MRI scans with FLAIR, DWI with b-value of 0 (B0) and $1000s/mm^2$, and DIR sequences. Patients were categorized into four groups: within three hours, three to six hours, six to 24 hours, and 24 to 48 hours after onset. Lesion-to-normal ratio (LNR) value was calculated and compared among all sequences within each group, by the Friedman test and conducted among all groups, for each sequence by the Kruskal-Wallis test. In qualitative assessment, signal intensity changes of DIR, B0, and FLAIR based on similarity with DWI and image quality of each sequence, were graded on a 3-point scale, respectively. Scores for detectability of lesions were compared by the McNemar's test. Results: LNR values from DWI were higher than DIR, but not statistically significant in all groups (P > 0.05). LNR values of DIR were significantly higher than FLAIR within 24 hours of onset (P < 0.05). LNR values were significantly different between, before, and after six hours onset time for DIR (P = 0.016), B0 (P = 0.008), and FLAIR (P = 0.018) but not for DWI (P = 0.051). Qualitative analysis demonstrated that detectability of DIR was higher, compared to that of FLAIR within 4.5 hours and six hours of onset (P < 0.05). Also, the DWI quality score was lower than that of DIR, particularly relative to infratentorial lesions. Conclusion: DIR provides higher detectability of hyperacute brain ischemia than B0 and FLAIR, and does not suffer from susceptibility artifact, unlike DWI. So, DIR can be used to replace evaluation of the FLAIR-DWI mismatch.