• Title/Summary/Keyword: image analysis software

Search Result 681, Processing Time 0.032 seconds

Development of Image Processing S/W for UT-NDE of Steam Generator of Nuclear Power Plant (핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발)

  • Lee, Young-Seock
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.217-222
    • /
    • 2006
  • This paper describes a development of ultrasonic examination analysis software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. This software provides the information of shape, depth, size and position of flaws. To do such, we obtain raw data from specimens and/or real pipeline of power plants and, modify the obtained ultrasonic 1-dimensional data according to prepared software design schedule. The developed analysis software is applied to specimens containing various flaws with known dimensions. The results of applications showed that the developed software provided accurate and enhanced images of flaws on various specimens.

  • PDF

Efficient Modifications of Cubic Convolution Interpolation Based on Even-Odd Decomposition (짝수 홀수 분해법에 기초한 CCI의 효율적인 변형)

  • Cho, Hyun-Ji;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.690-695
    • /
    • 2014
  • This paper presents a modified CCI image interpolation method based on the even-odd decomposition (EOD). The CCI method is a well-known technique to interpolate images. Although the method provides better image quality than the linear interpolation, its complexity still is a problem. To remedy the problem, this paper introduces analysis on the EOD decomposition of CCI and then proposes a reduced CCI interpolation in terms of complexity, providing better image quality in terms of PSNR. To evaluate the proposed method, we conduct experiments and complexity comparison. The results indicate that our method do not only outperforms the existing methods by up to 43% in terms of MSE but also requires low-complexity with 37% less computing time than the CCI method.

Development of Automated Display Image Characteristic Inspection System of Braun Tube(CRT) (브라운관의 화상계측 자동화 시스템 개발)

  • 유우식;장성호;이도경
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.35
    • /
    • pp.1-8
    • /
    • 1995
  • Automatic inspection system software for display image characteristic of CRT is developed. There are two major contributions of this software development. One is that the data from measuring equipments which was usually collected manually is automatically collected through RS-232C port and is saved in computer, then, trend analysis graph and final reports are generated. The other is that evauation of characteristic of electron gun was automatically processed by CCD camera and image processing technique. The system is developed under MS-Windows environment utilizing Borland C++4.0 Compiler and DT 3852-8 image processor board. This system can save the time and man power to measure and to anayze the image characteristics relative to current method.

  • PDF

Comparison of Image reformation Using Personal Computer with Dentascan Program (CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구)

  • KIM Eun Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF

Camera Source Identification of Digital Images Based on Sample Selection

  • Wang, Zhihui;Wang, Hong;Li, Haojie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.7
    • /
    • pp.3268-3283
    • /
    • 2018
  • With the advent of the Information Age, the source identification of digital images, as a part of digital image forensics, has attracted increasing attention. Therefore, an effective technique to identify the source of digital images is urgently needed at this stage. In this paper, first, we study and implement some previous work on image source identification based on sensor pattern noise, such as the Lukas method, principal component analysis method and the random subspace method. Second, to extract a purer sensor pattern noise, we propose a sample selection method to improve the random subspace method. By analyzing the image texture feature, we select a patch with less complexity to extract more reliable sensor pattern noise, which improves the accuracy of identification. Finally, experiment results reveal that the proposed sample selection method can extract a purer sensor pattern noise, which further improves the accuracy of image source identification. At the same time, this approach is less complicated than the deep learning models and is close to the most advanced performance.

Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions (미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.149-155
    • /
    • 2018
  • Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.

Energy-Efficient Biometrics-Based Remote User Authentication for Mobile Multimedia IoT Application

  • Lee, Sungju;Sa, Jaewon;Cho, Hyeonjoong;Park, Daihee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.6152-6168
    • /
    • 2017
  • Recently, the biometric-based authentication systems such as FIDO (Fast Identity Online) are increased in mobile computing environments. The biometric-based authentication systems are performed on the mobile devices with the battery, the improving energy efficiency is important issue. In the case, the size of images (i.e., face, fingerprint, iris, and etc.) affects both recognition accuracy and energy consumption, and hence the tradeoff analysis between the both recognition accuracy and energy consumption is necessary. In this paper, we propose an energy-efficient way to authenticate based on biometric information with tradeoff analysis between the both recognition accuracy and energy consumption in multimedia IoT (Internet of Things) transmission environments. We select the facial information among biometric information, and especially consider the multicore-based mobile devices. Based on our experimental results, we prove that the proposed approach can enhance the energy efficiency of GABOR+LBP+GRAY VALUE, GABOR+LBP, GABOR, and LBP by factors of 6.8, 3.6, 3.6, and 2.4 over the baseline, respectively, while satisfying user's face recognition accuracy.

Use of the surface-based registration function of computer-aided design/computer-aided manufacturing software in medical simulation software for three-dimensional simulation of orthognathic surgery

  • Kang, Sang-Hoon;Lee, Jae-Won;Kim, Moon-Key
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.197-199
    • /
    • 2013
  • Three-dimensional (3D) computed tomography image models are helpful in reproducing the maxillofacial area; however, they do not necessarily provide an accurate representation of dental occlusion and the state of the teeth. Recent efforts have focused on improvement of dental imaging by replacement of computed tomography with other detailed digital images. Unfortunately, despite the advantages of medical simulation software in dentofacial analysis, diagnosis, and surgical simulation, it lacks adequate registration tools. Following up on our previous report on orthognathic simulation surgery using computer-aided design/computer-aided manufacturing (CAD/CAM) software, we recently used the registration functions of a CAD/CAM platform in conjunction with surgical simulation software. Therefore, we would like to introduce a new technique, which involves use of the registration functions of CAD/CAM software followed by transfer of the images into medical simulation software. This technique may be applicable when using various registration function tools from different software platforms.

Development of HCS(High Contents Screening) Software Using Open Source Library (오픈 소스 라이브러리를 활용한 HCS 소프트웨어 개발)

  • Na, Ye Ji;Ho, Jong Gab;Lee, Sang Joon;Min, Se Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.6
    • /
    • pp.267-272
    • /
    • 2016
  • Microscope cell image is an important indicator for obtaining the biological information in a bio-informatics fields. Since human observers have been examining the cell image with microscope, a lot of time and high concentration are required to analyze cell images. Furthermore, It is difficult for the human eye to quantify objectively features in cell images. In this study, we developed HCS algorithm for automatic analysis of cell image using an OpenCV library. HCS algorithm contains the cell image preprocessing, cell counting, cell cycle and mitotic index analysis algorithm. We used human cancer cell (MKN-28) obtained by the confocal laser microscope for image analysis. We compare the value of cell counting to imageJ and to a professional observer to evaluate our algorithm performance. The experimental results showed that the average accuracy of our algorithm is 99.7%.

A New Method for Measuring Fiber Length and Fiber Coarseness Using Image Analysis Technique (화상분석법을 응용한 섬유장 및 섬유 조도 측정법 개발)

  • 배진한;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.13-21
    • /
    • 2002
  • A new method for measuring fiber length and fiber coarseness was developed using image analysis technique. Measured fibers were transferred to a glass slide on a filter paper placed on a wire of the laboratory paper machine. After staining the fibers on the slide, mean fiber lengths and coarseness were measured by a commercial image analysis software, named KS400. The resultant data obtained from the image analysis displayed a close correlation with those from FS-200 and also showed excellent reproducibility as well as those from FS-200. The length of synthetic fibers over 10 mm long could be readily measured by this new analysis technique. Finally, a substantial improvement in precision for measuring fiber length and coarseness was made with less operator's effort for a given time.