• Title/Summary/Keyword: illuminating equipment

Search Result 240, Processing Time 0.022 seconds

Tracking ond Distance Measurement of the Moving Object in Stereo Camera System as a Security Equipment (방범 설비의 스테레오 카메라 시스템에서 이동객체의 추적과 거리측정)

  • 이재수;홍권의;손영우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.106-115
    • /
    • 2003
  • In crossing stereo camera system as a security equipment system, a new algorithm for the tracking method of the moving object and the measurement method of distance of the object from cameras to moving object is proposed. The stereo input images are matched by a pixel for the moving object extraction, then the moving elements obtained from an adaptive threshold's value for an error correction and the moving object area extracted by noise eliminative algorithm. In addition to, the moving object traced by control pan/tilt of cameras using a coordinate value of the moving object, and the measurement method of distance to moving object by using special features of the crossing stereo camera system is proposed. From the experimental results, the proposed algorithm was found to be able to measure of the distance and trace for moving object in a stereo security camera system. The error rate of a distance measurement be existed within 6%. Moreover in implementation the proposed algorithm, the stereo security system, the automatic moving robot system and the stereo remote control system will be applied practical application.

Study on the Generating Operations of the Induction Motor for Driving the Pump During Instantaneous Power Interruption (순간 정전시 펌프 구동용 유도전동기의 발전 동작에 관한 연구)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.65-70
    • /
    • 2016
  • Power interruption is a phenomenon that no voltage is displayed over a short time or long time. Most devices will not operate normally when the supply voltage is low or does not exist. However, the device can also be operated with a different power which is ensured by a separate power generation. Recently, power interruption has been reduced gradually by the improvement of electricity quality, its duration also has been very short. Induction motors are widely used for the pumping in the water and sewage facilities and power plant applications. The pump is used as a machine for moving the fluid in the high place from a low location. So pump equipment always have a potential energy. If a momentary interruption occurs, the potential energy of the pump is reversed as that of water turbine and motor is operated as generator. This study is an analysis for the voltage variation, current, torque and power flow by the generating operation of the induction motor before and after the change of momentary interruption.

A Study on the Transient State Characteristics of TFR-8 Cable caused by Over Current (과전류에 의한 TFR-8 케이블의 과도상태 특성에 관한 연구)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • The incidence of fires caused by electrical factors has increased with the growth in domestic electrical consumption. According to the national fire data system of national emergency management agency, electrical fires accounted for 20% of all domestic fires in the last 10 years. Electrical fires are mainly caused by short circuit, leakage current, defect in an electrical equipment, over load, utility fault, etc. The fault current can be several times larger than the nominal current, thereby exceeding the rated current of cable. Consequently, the cable conductor, typically copper wire, heats up to a temperature that ignites surrounding combustibles. This paper describes the transient characteristics of the 0.6/1kV, TFR-8 cable have been investigated, and analyzed under the over current conditions for reduce the risk of electrical fire by experimental and FEM analysis. The experimental and FEM(Finite Element Method) analysis results of temperature and resistance variation according to the over current in copper wires were analyzed. The experimental results coincide well with the FEM analysis.

Analysis on the Lighting Characteristics using KLDNet in Korea (낙뢰감지 네트워크를 이용한 한반도 낙뢰특성 분석)

  • Woo, Jung-Wook;Kwak, Joo-Sik;Koo, Kyo-Sun;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.117-123
    • /
    • 2009
  • Recently, the failures of electrical equipment have been reduced due to the improvement of its quality and the advance of operation techniques but the failure rates caused by natural disasters such as wind and lightning have been increased. To reduce the failures due to lightning, it is necessary for insulation design of transmission lines to be done, effectively. Also the analysis on the lightning characteristics is essential to the effective insulation design. In this paper, we describe lightning distribution, multiplicity, IKL(Iso-Keraunic Level) and amplitude distribution of lightning current base on the lightning data by KLDNet.

An Auto-tuning of PID Controller using Fuzzy Performance Measure and Neural Network for Equipment System (전력설비시스템을 위한 퍼지 평가함수와 신경회로망을 사용한 PID제어기의 자동동조)

  • 이수흠;박현태;이내일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 1999
  • This paper is proposed a new method to deal with the optimized auto-tuning for the Pill controller which is used to the process-control in various fields. First of all, in this method, 1st order delay system with dead time which is modelled from the unit step response of the system is Pade-approximated, then initial values are determined by the Ziegler-Nichols method. So we can find the parameters of Pill controller so as to minimize the fuzzy criterion function which includes the maximum overshoot, damping ratio, rising time and settling time. Finally, after studying the parameters of Pill controller by Backpropagation of Neural-Network, when we give new K, L, T values to Neural-Network, the optimized parameter of Pill controller is found by Neural-Network Program.rogram.

  • PDF

Design of DNP Controller for Robust Control of Auto-Equipment Systems (자동화 설비시스템의 강인제어를 위한 DNP 제어기 설계)

  • 조현섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.55-62
    • /
    • 1999
  • In order to perform a elaborate task like as assembly, manufacturing and so forth of components, tracking control on the trajectory of power coming in contact with a target as well as tracking control on the movement course trajectory of end-effector is indispensable. In this paper, to bring under robust ard accurate control of auto-equipnent systems which disturbance, parameter alteration of system, uncertainty ard so forth exist, neural network controller called dynamic neural processor(DNP) is designed. Also, the learning architecture to compute inverse kinematic coordinates transfonnations in the manirclator of auto-equipnent systems is developed ard the example that DNP can be used is explained The architocture and learning algorithm of the proposed dynamic neural network, the DNP, are described and computer simllations are provided to demonstrate the effectiveness of the proposed learning method using the DNP.he DNP.

  • PDF

A Research on the Actual Conditions of the Electric Shock Hazard of a Guard Lamp (보안등의 감전 위험성에 관한 실태조사)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.32-38
    • /
    • 2005
  • In this paper, guard lamps at three areas have been investigated to understand the actual conditions of the electric shock hazard of the guard lamps. Upon the basis of the obtained data, the actual conditions of the guard lamps were precisely analyzed in terms of the electric shock hazard. As a result of the investigation, it was turned out that many guard lamps were not installed in organized ways due to the lack of legal regulations, resulting in the increase of electric shock hazard. Therefore, it is necessary, from a point of electric shock protection view, to establish the regulations of equipment installation and management, which can be specifically applied to guard lamps.

Assessment Software of Hormonic Emission Limits for Transmission System (송전계통 고조파 방출 한계 평가 소프트웨어)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeong, Young-Soo;Park, Sang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.134-140
    • /
    • 2007
  • In recent years, power equipment and system standards have been increasing in both number and complexity. The standards that will soon be introduced to KOREA is the transmission system standards for harmonic emission limits assessing in distorting loads. Utility engineers, being under increasing time constraints, are turning more and more to software to quickly solve problems. This paper describes the methodology used to implement the above standards in Microsoft Excel in order to assist utility engineers to readily apply these standards in practical situations.

The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques (신호처리 기술에 의한 부분방전 방사전자파의 특징 추출)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2002
  • In recent years, diagnostic techniques have been investigated to detect a partial discharge(PD) in a high voltage electrical equipment. Because PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise, the accuracy and credibility of PD measurement might be influenced by surrounding interference. Using the technique of PD detection by electromagnetic wave, we have studied the characteristics of both PD and substation-in interference signal. Also, we propose a wavelet packet transform based technique to perform a feature extraction from the interference and PD signal and a classification of the extracted features. The results show that time-frequency characteristics between PD and interference can be obviously distinguished. It is helpful for the development of the insulation diagnosis technique.

A Study on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Commercial Facility Loads (상업용 설비 부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.54-60
    • /
    • 2004
  • With the proliferation of nonlinear loads such as commercial facilities in all of modern society high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to commercial office loads for eliminating harmonics. Experimental results m compared numerically and graphically with simulation results through the use of MATLAB.