• Title/Summary/Keyword: illuminating equipment

Search Result 240, Processing Time 0.026 seconds

A Study on the Buckling Characteristics of Single-Layer Latticed Domes under Equipment-Loading (설비하중을 고려하는 단층래티스돔의 좌굴특성에 관한 연구)

  • 박지영;정환목;권영환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.83-88
    • /
    • 1994
  • Recently, the equipments of the structure are increasing remarkably. It is very important to evaluate the stability of the domes under concentrated loading such as a large-scale illuminating, visional, and sound equipment. The paper is aimed at investigating the buckling characteristics of single-layer latticed domes with triangular network under the uniformly distributed vertical-loading and the partially concentrated equipment-loading. The results show that the effects of the equipment-loading on the buckling strength is much more sensitive in domes of overall buckling than in domes of member buckling.

  • PDF

Energy Saving Smart Illuminating System Implementation Based on Obstacle Environment Presetting (장애환경설정 기반의 에너지절약 지능형 조명시스템 구현)

  • Kim, Young Bin;Ryu, Conan K.R.
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2786-2791
    • /
    • 2014
  • This paper describes the smart illuminating system based on the obstacle environmental presetting to improve the user convenience to easy lighting and energy conservation. Obstacle environment has trouble controlling the illuminating equipment using manual buttons in certain circumstances, which requires a smart remote controller. The smart remote controller is operated by the smart phone, motion sensor and timer to turn on and off the lamps. The event sensor module transmits the signals of the event occurrence to equipment on the remote place when smart phone and motion sensor detect an event, and the illuminator received the event turn on or off the lamp. The system results in energy saving by simple on/off control and manipulating the operating time with controlling the illuminating system preset by user's obstacle or preference circumstances. The proposed system implementation is experimented to figure out the energy saving about13.5w/h and the optimized convenience control.

Pro-environmental Solar-cell Power Source and Electro-luminescent Tape illumination for Cave Management (동굴관리를 위한 친환경 쏠라-셀 전원장치와 면광원 전자발광테이프 동굴조명)

  • Soh, Dae-Wha;Byun, Kil-Ho;Han, Sang-Yup
    • Journal of the Speleological Society of Korea
    • /
    • no.64
    • /
    • pp.13-26
    • /
    • 2004
  • In this paper, it was studied to investigate and apply the optimal method for well-management of cave with use of solar-cell power source and electro-luminescent tape of illuminating equipment of flat light - lamp for build up the pro-environmental management system of the long way cave on the mountain or the others.

Development of a 3-D Visualization Application for Management of Substation Equipment

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.38-44
    • /
    • 2009
  • This paper presents a new windows application based on 3-D graphics and Text-To-Speech (TTS) for effective management of substation equipment. When problems in a power system occur, inexperienced power system operators may have difficulty in understanding the situation as well as finding suitable countermeasures quickly. This paper addresses an effective scheme to visualizing power system equipment under normal and abnormal conditions using 3-D graphics and animations. In addition, the state variations and the order of maintenance priority of substation equipment are represented by TTS and intuitive methods. The proposed system can help power system operators to more quickly understand the state of power system equipment, and it can provide operators with the suitable countermeasures for minimizing damage caused by equipment problems.

A Study on the Improvement of Energy Efficiency in Warehouses (물류센터의 에너지 효율 개선 방안에 관한 연구)

  • Sun, Jong-Keun;Ryoo, Ho-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.66-72
    • /
    • 2012
  • The main sources of energy consumption in warehouses are MHE(Material Handling Equipment), HVAC(Heating, Ventilating and Air Conditioning) and Lighting. Warehouses in advanced countries raise energy efficiencies with energy consumption diagnosis, technology development and systematic management and improvements for MHE, HVAC and Illuminating, etc. They have managed illuminating system, air conditioning, motor driven system, air circulation method, dock facility, layout, AS/RS, conveyor system and battery management, etc. Ansong Pyeongtaek area investigation resulted that 43.9[%] of enterprises are managing partly energy consumption source. But the data resulted with not substantial management of energy consumption but passive management for only electric bill curtailment. Therefore through survey research & visiting interviews of some companies in Ansong Pyeongtaek area, we understood the status of energy consumption source management and proposed energy efficiency methods on the basis of that results.

The operating system of high-power LED module with back-boost mode (Back-Boost 방식 고출력 LED 구동시스템)

  • Chung, J.H.;Song, S.G.;Choi, J.H.;Park, S.J.;Moon, C.J.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.682-686
    • /
    • 2005
  • Recently the study is being addressed on the energy economy as greatly as possible. The researches on light source that have higher efficiency than the exiting are performing. The high-power LED is the representative one among those. There are two fields in the research on the high-power LED, the ordinary illuminating apparatus and the night illuminating apparatus using wind and solar energy. In this paper, we validated the probability of using high-power LED as illuminating apparatus and proposed the novel LED power equipment that has more stability and better efficiency than the exiting method. By using the propose method the -R-E-A-C-T is reduced and the efficiency improved.

  • PDF

The Effect Analysis in case of the Countermeasure and Trouble-Examples for the Noise of Control Equipment System (제어설비 계통에서의 노이즈장해 사례 및 대책별 효과 분석)

  • Kim, Hong-Ju;Yoo, Sang-Bong;Lee, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.75-81
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise the mis-operation equipment and demage program memories of control circuits. In this paper, the noise character of the various control equipment system has been measured and analyzed. Additionally, the countermeasure to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and confirmed the effective results to solve the trouble of noise.