• 제목/요약/키워드: illuminance levels

검색결과 53건 처리시간 0.03초

청천공 조건에서 조광제어 시스템 적용시 조도변화에 대한 시각적 만족도 분석 (The Influence of Illuminance Variation by a Daylight Dimming Control System on Visual Comfort Under Clear Sky Conditions)

  • 김수영
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.553-561
    • /
    • 2010
  • This study examines the influence of light variation on visual responses in a small office space where a daylight dimming control system is applied. Field measurements and survey were performed in a full-scale mocked-up small office space under clear sky day conditions. Maximum fluctuation range for desktop was 133.5 lx and it just happened once for entire monitoring period. For the majority of time, the fluctuation range did not exceed 50 lx, which did not cause visual discomfort to subjects. The daylight dimming control system successfully kept required illuminance levels for an office environment when desktop illuminance by daylight ranged up to 300 lx. The most serious contributor to the sensation of glare was direct daylight through window. The dimming of electric light was not a significant contributor to visual discomfort for the subjects under clear sky day conditions. Visual comfort was significantly influenced by the sensation of glare, feeling for visual stimulation and distraction, and required illuminance level.

실내공간의 복합 환경 조건이 인체의 생리 및 심리반응에 미치는 영향 (The Combined Environmental Factors on the Human Physiological and Psychological Responses in Indoor Space)

  • 윤인
    • 한국산업융합학회 논문집
    • /
    • 제15권3호
    • /
    • pp.87-94
    • /
    • 2012
  • Kruithof demonstrated the preferred combination of illuminance levels and color temperatures. However, as Benett pointed out, difference of themal variables in such preference may be expected. The purpose of this study is to clarify the combined effects of lighting conditions(illuminance, color temperature), operative temperature on the human physiological and psychological responses. In order to observe operative temperature change in preference of color temperatures for three illumination levels, three subjects were exposed to two different conditions of color temperatures of 2,850K, 4,200K and 6,850K combined with operative temperatures(OT) of $25{\sim}31^{\circ}C$ at 100~1000lx. Thermal sensation vote and comfortable sensation vote, brightness perception vote were reported in each experiment conditions. The following results were obtained : 1) When illuminace level was at 100lx in operative temperatures of OT $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$, Color temperature affect not themal sensation but Warm-cool sensation. 2) Operative temperatures affect not brightness perception vote but visual comfort sensation vote, satisfactive sensation vote, warm-cool sensation vote and themal sensation vote.

축소모형 실험을 통한 일조창과 태양의 기하학적 위치관계에 따른 실내조도분포 특성 (The Effect of Geometric Relation between the Window and the Sun on the Interior Illuminance Distributions using a Physical Scale Model)

  • 김민성;송규동
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.33-40
    • /
    • 2005
  • The existing building code regulates the minimum distance between buildings and the minimum required sunshine hours for winter solstice to ensure the right to light. Especially, the minimum sunshine hours have been guaranteed by the constitution after the right for the people to live in a healthy and comfortable environment was established. However, the existing regulation on the sunshine hours only considers the duration of sunshine hours, but ignores the minimum amount of sunlight. Therefore, the calculated sunshine hours are not coincident with the hours occupants actually feel. Therefore, the purpose of this study is to investigate the effect of solar incident angle on interior illuminance distribution, which will be used to propose a new code on the minimum sunshine hours and levels.

광센서 조광제어시스템의 폴링주기 결정에 관한 연구 (A Study on Determination of Poiling Period of Daylight Responsive Dimming Systems)

  • 황민구;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.213-216
    • /
    • 2005
  • Recently, energy depleting problem have risen seriously. Many studies of daylight responsive dimming system for saving of lighting energy in office buildings have been done actively. Most of studies are focused on the accuracy. However if the variation of dimming levels is changed too often, occupants would feel uncomfortable. First, illuminance changes which occupants couldn't detect are studied through analyzing foreign studies. Second, workplan illuminance from daylight in each sky condition is measured. Because the dimming level In daylight responsive dimming system is dependent on the workplan illuminance from daylight. In conclusion, the most appropriate polling periods to daylight responsive dimming system for occupant's visual comfort was determined.

  • PDF

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

Setting of the Operating Conditions of Stereo CCTV Cameras by Weather Condition

  • Moon, Kwang;Pyeon, Mu Wook;Lee, Soo Bong;Lee, Do Rim
    • 한국측량학회지
    • /
    • 제32권6호
    • /
    • pp.591-597
    • /
    • 2014
  • A wide variety of image application methods, such as aerial image, terrestrial image, terrestrial laser, and stereo image point are currently under investigation to develop three-dimensional 3D geospatial information. In this study, matching points, which are needed to build a 3D model, were examined under diverse weather conditions by analyzing the stereo images recorded by closed circuit television (CCTV) cameras installed in the U-City. The tests on illuminance and precipitation conditions showed that the changes in the number of matching points were very sensitively correlated with the changes in the illuminance levels. Based on the performances of the CCTV cameras used in the test, this study was able to identify the optimal values of the shutter speed and iris. As a result, compared to an automatic control mode, improved matching points may be obtained for images filmed using the data obtained through this test in relation to different weather and illuminance conditions.

휴게실 공간의 조명환경에 대한 시각적 감지 및 심리적 반응에 따른 공간 인지도 변화 (Variation of Spatial Cognition According to Visual Perception and Psychological Responses for Lighting Environments in Rest Space)

  • 김재상;이지현;김수영
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.443-453
    • /
    • 2012
  • This study examines visual perception and spatial satisfaction according to lighting conditions. Field measurements and surveys were performed in three rest space of university buildings where various lighting conditions were employed. Results indicate that overall impression of space improved when low color temperature, such as 3,000 K governed overall lighting environment and accent lighting was used for wall surfaces. Lighting conditions that kept uniform illuminance levels using area light sources containing fluorescent lamps with 6,500 K failed to keep favorable spatial satisfaction for space. High color temperature was not recommended for lighting in rest space. Asymmetrical illuminance levels formed by low color temperature such as 3000 K is recommended to keep positive mood and improve spatial satisfaction in rest space. Overall impression of the space was influenced by visual comfort, color temperature, spatial satisfaction and brightness. Spatial satisfaction for space was effectively impacted by psychological comfort, color temperature and overall impression for lighting conditions. Psychological comfort in space was influenced by color temperature, spatial satisfaction and visual annoyance from reflected light.

태양추적식 자연채광 장치의 집광기 종류에 따른 성능 분석: 포물 반사경 vs. 프레넬 렌즈 (Performance Analysis on Solar Tracking Daylighting Systems Using Different Types of Solar Collectors: Parabolic Dish vs. Fresnel Lens)

  • 김영민;김원식;정해준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.39-45
    • /
    • 2017
  • This paper presents the effect of solar collectors on the performance of solar tracking daylighting systems. A series of measurements were made for two different types of solar collectors mounted on double axis solar trackers: Parabolic dish concentrator and Fresnel Lens. Indoor light levels were measured at different locations of an office space (longitude: 126.33 E, latitude 33.45 N) as photo sensors were placed on a task plane 80 cm above the floor. To accurately monitor the applicability of the systems, measurements were performed under clear and overcast sky conditions with the roll-screen (on the south window) in the down position. Comparing the illuminance data, the system with Fresnel lens outperformed that of parabolic dish concentrator. On clear days, the former delivered the light levels of 400~600 lux on the task plane whereas the latter recorded 100~200 lux. Depending on the amount of cloud cover, on overcast days, illuminance readings fluctuated to some extent.

광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가 (Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method)

  • 김동수;윤종호;신우철;이광호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측 (Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.