• Title/Summary/Keyword: illuminance levels

Search Result 53, Processing Time 0.035 seconds

Analyses of the Impact of Atmospheric Conditions to Daylight Illuminance in a Small Space (기상인자의 변화에 따른 소규모 공간에서의 주광조도분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • Daylight illuminance levels in a small space were calculated using the Superlite program under limited conditions of the turbidity and thickness of condensible water of atmosphere. Three sky conditions(clear sky with direct sun, clear sky with no direct sun, overcast sky with no direct sun) were used. The atmospheric conditions significantly impacted the illuminance levels under especially a clear sky with direct sun. The overcast sky with no direct sun provided no difference for the illuminance levels in the space. As the calculation points moved away from a window, reflected illuminance levels gradually increased but direct illuminance levels significantly decreased.

Analysis of User Preference about the Color Rendering Index, Correlated Color Temperature and Illuminance of LED Lighting in Merchandising Spaces (상업공간에서의 사용자 선호 LED 조명 연색지수와 상관색온도, 조도의 분석)

  • Lee, Su-Jung;Yoon, Hea-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This study aims to recommend the proper Color rendering index (CRI), the Correlated Color Temperature (CCT), and illuminance levels of Light-Emitting Diode (LED) lighting based on the analysis of the criteria of the current CRI, the CCT, and illuminance levels in merchandising spaces with LED lighting conditions. It would be a basic material to apply in line with user preference for LED merchandising lighting. To this end, it examines relevant literature review on the experiments designed to test whether lighting characteristics affect brightness perception, color appearance, and pleasantness. Highly saturated colors appear brighter than low saturated colors. Two lighting applications - grocery and clothing shop - were created in elaborating the effect of LED lighting characteristics of CRI on color appearance and the CCT and illuminance on pleasantness. The findings show that the criteria of CIE Ra<80 are appropriate to provide better color appearance of illuminated products in terms of LED lighting that can enhance color saturation, particularly for the red color. Furthermore, 2700 K and less than 500 lux for grocery, 4000 K and more than 500 lux for clothing shop are found to be the proper the CCT and illuminance levels respectively to bring better preference under LED lighting.

Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium (축구 경기장의 조명타워 위치에 따른 조도분포 해석)

  • 김길영;최홍규;최병숙
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Nowadays the soccer becomes one of the best spot lighting sports in the world Especially the 2002 Korea-Japan World Cup was deeply impressed on all the korean. One goal of illuminating engineering should be the design of lighting system that can provide consistently high task visibility regardless of where a task might be located within a working space. The television broadcasting on the soccer has been an important role in the media. The standard of FIFA(The Federation Internationale do Football Association) requires recommended illuminance levels for artificial lighting for a player, an audience, TV broadcasting, as well as everybody in the stadium. This paper has proposed an algerian to select the suboptimal lighting tower position for watching and TV broadcasting a soccer game within a pleasant environment and an optimum illuminance distribution. The position using the software Philip's Calculux was chosen based an the calculations of a horizontal illuminance, vertical illuminance, uniformity, glare, and so on by changing lighting tower positions.

Characteristics of the Illuminance Distributions by Artificial Lighting in Different Shading Systems (쉐이딩 시스템에 따른 인공조명에 의한 조도분포 특성에 관한 연구)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • Daylight responsive dimming system, which is one of the method for utilizing available daylight. continuously adjusts lighting output with an algorithm of the correlation of photosensor signal and workplane illuminance levels. This system must be related with shading systems which are to control penetrating daylight. The purpose of this research is to analyze illuminance distributions by artificial lighting in different shading systems. Lighting power is changed by 5 levels in nighttime for comparing correlation between illuminance and lighting power in different shading systems.

  • PDF

Daylighting Performance Evaluation of window Integrated Light Shelf System (창호일체형 광선반 시스템 채광성능 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.41-46
    • /
    • 2007
  • The lightshelf system, a horizontal shading and light redirect device, should improve the visual environment by optimal light distributions and intense illumination levels of a interior. This study aims to evaluate the daylighting performance of window integrated lightshelf systems by computer simulations. For the study, the standard office plan is analyzed through the field surveys. And then, the various lightshelf types attached window systems are picked out from existed research results. The max, minimum and average illuminance levels of interiors and illuminance distributions are evaluated by Lightsacpe 3.2 programs based on the installing height, shape type and moving angle of lightshelfs. As results, it is suggested that the optimum lightshelf shapes are the height 1.8m and the width 600mm. Also, in mixed lightshelf, the outside width 600mm, inside width 400 are efficient on indoor daylighting performance.

Analysis on Visual Perception and Mood for Color of Light in a Small Office (소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석)

  • Kang, Min-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Study on the Development of Database for Lighting Design System (조명 설계 시스템을 위한 데이터베이스 개발에 관한 연구)

  • 조성오
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.196-203
    • /
    • 2004
  • In The Lighting design is important to acknowledge appearance space. Development of artificial light makes a extension to life space in the Modern life. With the rapid development of efficient light sources, have lighting design acquired the tools that allow artificial lighting to be produced with adequate illuminance levels. However, by the task of defining the objectives and methods behind discipline, of deciding on the criteria by which the artificial lighting that is now provide many available data to be anpaied. The main concern is which illuminace levels and types of lighting will ensure optimum visual performance, high productive and safety at design which are affordable. This study is support to standard design process with material reflection rate, installing the lighting fixture, task illuminance level and automatic arithmetic calculation during the lighting design. Lighting Design database can check and support other final lighting level. A quantitative light that is primarily oriented toward providing a recommended illuminance level, the criterion of develop a concept that goes beyond the requirements that would ensure productivity and safety to meet the needs of the architecture and interior space. illuminance level is compose to space task and space code according to KS A 3011. To be able to design the visual effect of an environment the central reference quantity has to provided the Database.

The Effect of Illuminance and Color Temperature of LED Lighting on Occupants' Perception and HRV

  • Seo, Han Suk;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose: It is crucially important that indoor luminous conditions of built environments be carefully studied so as to promote comfort and occupants' well-being. Method: The current study therefore focuses on the lit aspect of an enclosed space considered to be a resting room ($4.5m{\times}6.32m{\times}2.5m$). Particularly, on the effect that light levels and light color temperatures have on the physiological and psychological responses of resting occupants. To do so, a questionnaire survey was carried out on 50 subjects. The independent variables for the experiment included 9 different luminous environment conditions setup using 3 different levels of illuminance (50 lx, 150 lx, 300 lx) and 3 different color temperatures (2000 K, 3800 K, 5600 K). A questionnaire was utilized in determining which conditions were preferred by occupants. Result: As it turns out, indoor luminous environment designed for relaxation purposes should display luminance levels of at least 150 lx and 3800 K of color temperature in order to provide a visually comfortable environment suitable for the occupant's relaxation while at the same time promoting the psychological and HRV well-being of resting occupants.

A Study on the application of appropriate level of illuminance to the Cathedral based on lighting principles (조명원리를 기반으로 한 성당조도의 적정수준 적용분석 연구)

  • Bahn, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.685-696
    • /
    • 2017
  • In the spatial image composition of a cathedral, light is the most important element of changing the mind through vision. The religious meaning of light and its impact on human sensibility are believed to be very large. Therefore, in this study, 'Illuminance' is the most important research subject of a cathedral's worship space lighting plan elements. Illuminance is expressed by giving the clarity and form of space through a subtle spatial composition difference. The role of illuminance is essential for confirming the existence of space, and lighting controls the spatial atmosphere at an appropriate level. The standard and range of illuminance are set through the synthesis and analysis of related standards. Based on this, a related case study was conducted on cathedrals built in the Gangnam area of Seoul in the 1980s. The lighting-related factors were analyzed and the illuminance of the liturgical space and worship area were measured. The appropriate level of applicability was confirmed by comparison analysis. A plan for the illuminance application levels and elements applied in the cathedral lighting design is proposed.