• Title/Summary/Keyword: identical

Search Result 5,165, Processing Time 0.03 seconds

cDNA Sequences for Asialoglycoprotein Receptor from Human Fetal Liver

  • Lee, Dong-Gun;Lee, Sung-Gu;Kim, Kil-Lyong;Hahm, Kyung-Soo
    • BMB Reports
    • /
    • v.30 no.4
    • /
    • pp.299-301
    • /
    • 1997
  • The asialoglycoprotein receptor (ASGPR) was the first described mammalian lectin that mediates the specific binding and internalization of galactose/N-acetylgalactosamine-terminating glycoproteins by hepatic parenchymal cells. H1 and H2 are known as essential subunits of the functional ASGPR. There were close similarities in ASGPR H2 subunits between cultured cell line HepG2 and normal human liver cells including identical sequences at both termini. It was therefore expected that there may be some similarities between the subunits from normal liver cells and fetal liver cells. The two subunits of human fetal liver ASGPR. designated FL-H1 and FL-H2. were cloned from cDNA library by peR and the sequences were compared with the known HI and H2 sequences of HepG2, and the H1 sequence of nornal human liver cells. The results showed that FL-H1 was identical to H1 of HepG2. Whereas FL-H2 contains a 15-bp miniexon, but missing 57-bp at the near upstream from the membrane-spanning domain compared to H2 of HepG2 and normal human liver cells indicating that FL-H2 resulted from a differential splicing compared to HepG2 and normal liver cells.

  • PDF

Chronic Granulomatous Disease on Jeju Island, Korea

  • Cho, Moonjae;Shin, Kyung-Sue
    • Journal of Genetic Medicine
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Chronic granulomatous disease (CGD) is a rare inherited disorder of a defective NADPH oxidase enzyme, resulting in very low or no production of superoxide and subsequent reactive oxygen species. Consequently, patients with CGD are highly susceptible to severe bacterial and fungal infections. CGD is a genetically heterogeneous disease caused by defects in any one of the genes encoding the NADPH oxidase components. CGD generally affects about 3-4 per 1,000,000 individuals; thus, it is surprising that the prevalence of CGD on Jeju Island is 34.3 per 1,000,000 individuals. At present, 20 patients with CGD from 14 unrelated families on Jeju Island have been identified; nine males and 11 females. All patients with CGD tested on Jeju Island had an identical and homozygous mutation (c.7C>T in CYBA, p.Q3X in $p22^{phox}$). Therefore, all patients were autosomal recessive form of CGD. This strongly suggests that the unique and identical mutation in CYBA may be inherited from a common proband. Using mutation-specific primers to detect the mutated allele in CYBA, the frequency of subjects carrying a mutated allele was 1.3% of enrolled subjects from Seogwipo City. Further studies are necessary to elucidate how frequently this mutant allele occurs in the population on Jeju Island. Additionally, it is important to construct a national registry system to understand the pathophysiology of CGD and develop a strategy for long-term therapy.

Applying the Identical Content to Various Types of Mobile Devices Using the Image Map Method (이미지 맵 방법을 이용한 다양한 모바일 단말기에서의 동일한 컨텐츠 적용)

  • Zhao, Mei-Hua;Seo, Chang-Woo;Ko, Hee-Ae;Lim, Young-Hwan
    • Journal of Internet Computing and Services
    • /
    • v.11 no.2
    • /
    • pp.173-184
    • /
    • 2010
  • The advancement of ubiquitous networks facilitates and increases access to the Internet via mobile devices, which offers the advantages of enhanced mobility and accessibility. While Mobile Internet is largely free of temporal and spatial restrictions, producing content for mobile websites is a challenging work due to the existence of multiple device types and markup languages. This paper proposes a technique that makes use of image maps to improve the visual consistency of mobile web content displayed on a variety of mobile devices. The proposed image map method captures several objects comprising the webpage into a single image, and provides the image in Mobile Web services. Mobile devices employing the proposed method can reorganize webpages with multiple objects more easily and obtain the visually identical content on their screen.

THE AUTOMATIC CALIBRATION OF KOREAN VLBI NETWORK DATA

  • HODGSON, JEFFREY A.;LEE, SANG-SUNG;ZHAO, GUANG-YAO;ALGABA, JUAN-CARLOS;YUN, YOUNGJOO;JUNG, TAEHYUN;BYUN, DO-YOUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • The calibration of Very Long Baseline Interferometry (VLBI) data has long been a time consuming process. The Korean VLBI Network (KVN) is a simple array consisting of three identical antennas. Because four frequencies are observed simultaneously, phase solutions can be transferred from lower frequencies to higher frequencies in order to improve phase coherence and hence sensitivity at higher frequencies. Due to the homogeneous nature of the array, the KVN is also well suited for automatic calibration. In this paper we describe the automatic calibration of single-polarisation KVN data using the KVN Pipeline and comparing the results against VLBI data that has been manually reduced. We find that the pipelined data using phase transfer produces better results than a manually reduced dataset not using the phase transfer. Additionally we compared the pipeline results with a manually reduced phase-transferred dataset and found the results to be identical.

AN EXPERIMENTAL STUDY ON COLOR DIFFERENCE BETWEEN PROCELAIN SYSTEMS FOR PORCELAIN-FUSED-TO-METAL CROWN (도재전장 주조관에 사용되는 도재의 색차에 관한 실험적 연구)

  • Paik, Sung-Ki;Chang, Wan-Shik;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.41-54
    • /
    • 1987
  • The purposes of this study were to evaluate the color differences those can exist between different brands of porcelain with identical shade designation, and to find their causes. For these purposes the following experiments were executed: The color of each opaque and layered porcelain specimen was determined by spectral reflectance measurements with a spectrophotometer. The compositions of each opaque porcelain powder were analyzed by qualitative, and quantitative analysis. Microscopic structures of each opaque porcelain were observed by scanning electron microscope. The results were as follows: 1. Identical shade of different brands of porcelain produced significantly different colors. 2. Color differences among the three brands were found under different light sources. 3. Color differences among the three brands were mostly a result of differences in kinds and amounts of opacifying agents and fluxes and microstructure of porcelain systems. 4. When porcelain systems have similar compositions and firing cycles, they produced similar colors.

  • PDF

Analysis on the Implementation Status of Domestic PBD (Performance Based Design) - Focusing on the Fire Scenario and Simulation (국내 성능위주설계의 시행현황 분석 - 화재시나리오 및 시뮬레이션을 중심으로)

  • An, Sung-Ho;Mun, Sun-Yeo;Ryu, Ill-Hyun;Choi, Jun-Ho;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.32-40
    • /
    • 2017
  • The current status of Performance-Based Design (PBD) implemented in 4 wide areas (Seoul, Gyeonggi, Incheon and Busan) over the past 5 years was reviewed with regard to the number of PBD implementation and target buildings. Then, detailed status related to fire scenarios, input information for fire simulation, and grid size were analyzed with the pre-review for the PBD. As a result, the domestic PBD was mainly applied to the mixed occupancy. In the fire simulations performed on the identical fire scenario and fire space, the maximum heat release rate (HRR) varied significantly depending on the PBD designer. Various combustibles were also considered for the identical fire source, and their combustion properties also showed considerable uncertainty. In addition, the applicability of accurate input information for predictive models of heat and smoke detectors was examined. Finally, the average grid size for the fire simulation using Fire Dynamics Simulator (FDS) was analyzed, and the improvement of PBD to minimize designer dependency was proposed.

Identification of a lead small-molecule inhibitor of anthrax lethal toxin by using fluorescence-based high-throughput screening

  • Wei, Dong;Bu, Zhaoyun;Yu, Ailian;Li, Feng
    • BMB Reports
    • /
    • v.44 no.12
    • /
    • pp.811-815
    • /
    • 2011
  • Inhalational anthrax is caused by B. anthracis, a virulent sporeforming bacterium which secretes anthrax toxins consisting of protective antigen (PA), lethal factor (LF) and edema factor (EF). LF is a Zn-dependent metalloprotease and is the main determinant in the pathogenesis of anthrax. Here we report the identification of a lead small-molecule inhibitor of anthrax lethal factor by screening an available synthetic small-molecule inhibitor library using fluorescence-based high-throughput screening (HTS) approach. Seven small molecules were found to have inhibitory effect against LF activity, among which SM157 had the highest inhibitory activity. All theses small molecule inhibitors inhibited LF in a noncompetitive inhibition mode. SM157 and SM167 are from the same family, both having an identical group complex, which is predicted to insert into S1' pocket of LF. More potent small-molecule inhibitors could be developed by modifying SM157 based on this identical group complex.

Microstructure and Mechanical Properties of Cu-Ni-Si Alloy Deformed by Differential Speed Rolling (이속압연에 의해 가공된 Cu-Ni-Si 합금의 미세 조직 및 기계적 성질)

  • Lee, Seong-Hee;Han, Seung Zeon
    • Korean Journal of Materials Research
    • /
    • v.26 no.1
    • /
    • pp.8-12
    • /
    • 2016
  • Effects of conventional rolling(CR) and differential speed rolling(DSR) on the microstructure and mechanical properties of Cu-Ni-Si alloy were investigated in detail. The copper alloy with thickness of 3 mm was rolled to 50 % reduction at ambient temperature without lubricant with a differential speed ratio of 2:1. The conventional rolling in which the rolling speed of upper and lower rolls is identical was performed under identical rolling conditions. The shear strain introduced by the CR showed positive values at positions of upper roll side and negative values at positions of lower roll side. However, it showed zero or positive values at all positions for the samples rolled by the DSR. The microstrucure and texture development of the as-rolled copper alloy did not show any significant difference between CR and DSR. The tensile strength of the DSR processed specimen was larger than that of the CR processed specimen. The effects of rolling methods on the microstructure and mechanical properties of the as-rolled copper alloy are discussed in terms of the shear strain.

The Study of Structural Stability by Stacking Method of the Axial Blade (축류 블레이드의 스태킹 방식에 의한 구조 안정성 연구)

  • Jeong, Cheol-Young;Ko, Hee-Hwan;Park, Jun-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.46-51
    • /
    • 2012
  • This study is to confirm the deformation of blade when the location of stacking is moving. Also, it desire to determine the most stable location of stacking from the analysis. In the previous study, it is Known that moving the location of stacking is not influence to the aerodynamic performance. In this study SolidWorks premium 2010 SP4 is used for structure analysis. In reference blade and other 3 model analysis, the two mesh type is used, one is standard mesh type in SolidWorks, the other is curvature-based mesh type. The result of curvature-based mesh type is more stable than one of the standard mesh type regardless of mesh size, the number of mesh. The deformation of blade tip is the smallest, when the location of stacking is identical to the center of gravity of the blade section profile. So, if possible is design, this study recommends that the location of stacking is identical to the center of gravity the blade.

PROBABILISTIC ANALYSIS OF A SYSTEM CONSISTING OF TWO SUBSYSTEMS IN THE SERIES CONFIGURATION UNDER COPULA REPAIR APPROACH

  • Raghav, Dhruv;Pooni, P.K.;Gahlot, Monika;Singh, V.V.;Ayagi, Hamisu Ismail;Abdullahi, Ameer Hassan
    • The Pure and Applied Mathematics
    • /
    • v.27 no.3
    • /
    • pp.137-155
    • /
    • 2020
  • Redundancy is commonly employed to improve system reliability. In most situations, components in the standby configurations are assumed statistically similar but independent. In many realistic models, all parts in standby are not treated as identical as they have different failure possibilities. The operational structure of the system has subsystem-1 with five identical components working under 2-out-of-5: G; policy, and the subsystem-2 has two units and functioning under 1-out-of-2: G; policy. Failure rates of units of subsystems are constant and assumed to follow an exponential distribution. Computed results give a new aspect to the scientific community to adopt multi-dimension repair in the form of the copula.