• Title/Summary/Keyword: ideal solution

Search Result 375, Processing Time 0.028 seconds

Infilled frames: developments in the evaluation of the stiffening effect of infills

  • Papia, M.;Cavaleri, L.;Fossetti, M.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.6
    • /
    • pp.675-693
    • /
    • 2003
  • In order to consider the modified seismic response of framed structures in the presence of masonry infills, proper models have to be formulated. Because of the complexity of the problem, a careful definition of a diagonal pin-jointed strut, able to represent the horizontal force-interstorey displacement cyclic law of the actual infill, may be a solution. In this connection the present paper shows a generalized criterion for the determination of the ideal cross-section of the strut mentioned before. The procedure is based on the equivalence between the lateral stiffness of the actual infilled frame scheme during the conventional elastic stage of the response and the lateral stiffness of the same frame stiffened by a strut at the same stage. Unlike the usual empirical approaches available in the literature, the proposed technique involves the axial stiffness of the columns of the frame more than their flexural stiffness. Further, the influence of the bidimensional behaviour of the infill is stressed and, consequently, the dependence of the dimensions of the equivalent pin-jointed strut on the Poisson ratio of the material constituting the infill is also shown. The proposed approach is extended to the case of infills with openings, which is very common in practical applications.

A decision making framework model for the selection of a RP using hybrid multiple attribute decision making techniques (3차원 조형장비 선정을 위한 복합 다요소 의사결정 구조 모델 개발에 관한 연구)

  • Byun, Hong-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.87-95
    • /
    • 2008
  • The purpose of this study is to provide a decision support to select an appropriate rapid prototyping(RP) machine that suits the application of a part. Selection factors include concept model, form/fit/functional model, pattern model for molding, material property, build time and part cost that greatly affect the performance of RP machines. However, the selection of a RP is not an easy decision because they are uncertain and vague. For this reason, the aim of this research is to propose hybrid multiple attribute decision making approaches to effectively evaluate RP machines. In addition, because subjective considerations are relevant to selection decision, a fuzzy logic approach is adopted. The proposed selection procedure consists of several steps. First, we identify RP machines that the users consider. After constructing the evaluation criteria, we calculate the weights of the criteria by applying the fuzzy Analytic Hierarchy Process(AHP) method. Finally, we construct the fuzzy Technique of Order Preference by Similarity to Ideal Solution(TOPSIS) method to achieve the ranking order of all machines providing the decision information for the selection of RP machines.

  • PDF

An Integrated AHP-VIKOR Methodology for Facility Layout Design

  • Shokri, Hamidreza;Ashjari, Behzad;Saberi, Morteza;Yoon, Jin Hee
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.389-405
    • /
    • 2013
  • A facility layout design (FLD) problem can be generally introduced as assignment of facilities (departments) to a site such that a set of criteria are satisfied or some objectives are minimized (maximized). Hence, it can be considered as a multi-criteria problem due to the presence of qualitative criteria such as maintenance or flexibility and quantitative criteria such as the total cost of handling material. The VIKOR method was developed to solve multiple criteria decision making problems with conflicting and non-commensurable (different units) criteria, assuming that compromising is acceptable for conflict resolution, the decision maker wants a solution that is the closest to the ideal, and the alternatives are evaluated according to all established criteria. This paper proposes a hierarchical analytic hierarchy process (AHP) and VIKOR approach to solve the FLD problem. A computer-aided layout-planning tool is adopted to generate the facility layout problems, as well as their quantitative data. The qualitative performance measures are weighted by AHP. VIKOR is then used to solve the FLD problem. Finally, the proposed integrated procedure is applied to three real-time examples.

Facile Fabrication of Bimetallic Catalysts via Selective N atoms of N-Doped Carbon Nanotubes and Their Superior Catalytic Activities for Hydrogen Generation (질소가 포함된 탄소나노튜브의 질소 원자를 이용한 이중 금속 촉매 제조 및 그의 수소 발생 촉매 특성 분석)

  • Shin, Weon Ho;Jeong, Hyung Mo;Choi, Yoon Jeong;Kang, Jeung Ku
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.111.2-111.2
    • /
    • 2010
  • One-dimensional nanostructures such as carbon nanotubes could be ideal templates for formation of metallic nanoparticles. Furthermore, bimetallic component nanoparticles have recently been interesting issues for having high catalytic activity. This work provides both a facile method to synthesize bimetallic catalysts via N atoms of carbon nanotubes and also a picture about how to design the optimal bimetallic catalyst for hydrogen generation from the hydrogen storage material. In principle, the ratio of one component to another component could be generically extended to fabricate the high-performance bimetallic catalysts on host nanostructures. Indeed, we demonstrate that the bimetallic catalyst composed of the optimum composition results in the excellent hydrogen generation property from an aqueous borane ammonia solution, thus being capable of satisfying the Depart of Energy in USA target required for many advanced applications even with the small amount of our bimetallic catalysts attached onto the N-doped carbon nanotubes. This high hydrogen generation rate is found to be attributed to the optimal distance between active Pt and cheap Ni atoms for effective hydrogen generation.

  • PDF

Effect of thermal treatment on spray deposited CdTe thin films (스프레이 증착법을 이용한 CdTe박막의 열처리에 따른 특성 분석)

  • Lee, Jinyoung;Hwang, Sooyeun;Lee, Taejin;Ryu, Siok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.49.2-49.2
    • /
    • 2010
  • Polycrystalline CdTe thin films for solar cell continues to be a promising material for the development of cost effective and reliable photovoltaic processes. The two key advantages of this material are its high optical absorption coefficient and its near ideal band gap for photovoltaic conversion efficiency of 1.4-1.5 eV. In this study we made the CdTe thin films for solar cell application which was deposited on the glass substrates using a modified chemical spray method at low temperature. This process does not require the sophisticated and expensive vacuum systems. The prepared CdTe films were characterized with the aid of scanning electron microscope (SEM), UV-visible spectrophotometer, and X-ray diffraction spectrometer (XRD). Following are results of a study on the "Human Resource Development Center for Economic Region Leading Industry" Project, supported by the Ministry of Education, Science & Tehnology(MEST) and the National Research Foundation of Korea(NRF).

  • PDF

Outside Plant Engineering for FTTH (FTTH 구축을 위한 OSP 특성 분석)

  • Oh Ho-Seok;Choi Young-Bok;Lee Won-Hyung;Kim Bo-Gyum;Park Tae-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.45-50
    • /
    • 2006
  • As a settlement for the fiber access, the FTTH is an ideal mode for providing various high-bandwidth value added services including high definition IPTV to broadband users, and KT, the largest incumbent of Korea, started FTTH service from 2005. For FTTH deployment, it needs a cost-effective solution including reliability and maintenance costs. This paper analyzes the characteristics and technical issues for the main components of outside plant in general household area.

Pre-Charged Particle Deposition in an Impactor subjected to an Electric Field (전기장이 형성된 관성 충돌기에서 대전 입자의 거동과 부착 특성에 대한 연구)

  • Park, Hyung-Ho;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.299-310
    • /
    • 1999
  • Effect of electrostatic and inertial forces on the pre-charged particle deposition was theoretically and experimentally studied by introducing the inertia impactor subjected to an electric field. To derive the analytic solution, we assumed that a flow was an ideal stagnation flow, a particle had saturation charges, and the electric field within the test section was uniform. On the other hand, $Al_2O_3$ particle groups were used as the test particles, which mean sizes were $1{\mu}m$, $3{\mu}m$, and $5{\mu}m$. To measure the deposition efficiency, the light scattering method was used. The results showed that the deposition efficiency was minimized at a certain nozzle velocity as increasing the nozzle velocity, only if the electric force was applied. As the electric field strength increased, $Stk_{50}{^{1/2}}$ was decreased, and its decreasing rate was reduced with increasing the flow velocity. Moreover the existence of electric field was against the cut-off performance of the inertia impactor.

A Cluster-Based Relay Station Deployment Scheme for Multi-Hop Relay Networks

  • Chang, Jau-Yang;Chen, Yun-Wei
    • Journal of Communications and Networks
    • /
    • v.17 no.1
    • /
    • pp.84-92
    • /
    • 2015
  • Multi-hop relay networks have been widely considered as a promising solution to extend the coverage area and to reduce the deployment cost by deploying the relay stations (RSs) in mobile communication systems. Suitable deployment for the RSs is one of the most important features of the demand nodes (DNs) to obtain a high data transmission rate in such systems. Considering a tradeoff among the network throughput, the deployment budget, and the overall coverage of the systems, efficient RS deployment schemes and corresponding algorithms must be developed and designed. A novel cluster-based RS deployment scheme is proposed in this paper to select the appropriate deployment locations for the relay stations from the candidate positions. To make an ideal cluster distribution, the distances between the DNs are calculated when deploying the RSs. We take into account the traffic demands and adopt a uniform cluster concept to reduce the data transmission distances of the DNs. On the basis of the different candidate positions, the proposed scheme makes an adaptive decision for selecting the deployment sites of the RSs. A better network throughput and coverage ratio can be obtained by balancing the network load among the clusters. Simulation results show that the proposed scheme outperforms the previously known schemes in terms of the network throughput and the coverage ratio. Additionally, a suitable deployment budget can be implemented in multi-hop relay networks.

Adsorption Characteristics of Heavy Metals in Wastewater on Bone Charcoal (Bone Charcoal에 의한 폐수증의 중금속 흡착특성)

  • Chung, Paul-Gene;Kwak, Dong-Heui;Lee, Jae-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.555-563
    • /
    • 2000
  • The study was conducted to evaluate the adsorption equilibrium of heavy metals on bone charcoal made of livestock bone which was sintered at $550{\sim}600^{\circ}C$. Analysis of bone charcoal by XRD and FT-IR showed that crystal structure was similar to that of synthetic hydroxyapatite. Adsorption equilibrium capacity of single component (Pb, Cd, and Zn) on bone charcoal could be expressed as Langmuir, Freundlich, and Sips equations. Sips isotherm was best among the three isotherms. The values predicted by IAST(ideal adsorbed solution theory) showed good relationship to the experimental data in multicomponent adsorption equilibrium. Adsorption affinity was in order of Pb, Cd, and Zn. The order was same in case of activated carbon or synthetic hydroxyapatite. Through the study results. it would be expected that bone charcoal made of livestock could be used in field of wastewater treatment plants as adsorbent to remove heavy metal.

  • PDF

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF