빙축 및 냉방열과정중 냉각유체와 Ice Ball사이의 열적 특성에 관한 실험적 연구 (An Experimental Study on Thermal Characteristics between Cooling Fluid and Ice Ball during Charging and Discharging Precesses)

  • 박경원;박이동;황영규;김윤제
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.193-205
    • /
    • 1996
  • This paper deals with experimental study on thermal characteristics that a cooling fluid is affected to ice ball as being measuring the temperature in storage tank and ice ball governing the rate of heat storage. Distributor was taken as inlet geometry factor. flow rate of cooling fluid which was a brine were 2, 4, and 6LPM, and 8, 10, and 12$^{\circ}C$ in the temperature difference for dynamic factors with respect to three ice ball types(103, 96, 76mm). In case of in flowing cooling fluid, since inertia force is suppressed by lower flow rate the amount of heat was transferred to ice ball by heat conduction high because density difference is high. And in case of larger ice ball, a long-term storage was available because reaching time at steady state is relatively long. consequently, smaller ice ball could be suitable to a short-term storage.

  • PDF

스테인레스 극판을 이용한 전해수장치의 수질특성과 오징어 선도유지를 위한 전해수 빙장 효과 (Water Properties of Electrolytic Machine by Stainless Diaphragm and Effects of Electrolytic Ice Water Storage For Keeping Freshness of Squid, Todarodes pacificus)

  • 이남걸
    • 수산해양교육연구
    • /
    • 제18권3호
    • /
    • pp.293-301
    • /
    • 2006
  • 연속식 스테인레스 단자 방식의 전해수의 기기특성과 오징어를 담수빙과 산성전해수빙, 염기성전해수빙 저장 중 선도보존 효과 및 표피색변화에 대하여 검토하여, 향후 연안 어류의 전기분해수 빙장 적용기초 자료로 이용하고자 연구한 결과를 요약하면 다음과 같다. 1. 본 연구에서는 TMD에서 개발된 기기에 단자를 구리에서 스테인레스로 교체한 TMD II기기의 성능을 평가하였다.실험결과 전체적으로 동일한 전류를 걸었을때, 산성전해수의 경우 낮은 pH를 유지했으며, 유량을 늘릴수록 산성도가 떨어지는 것을 알 수 있었다.본 장치는 단자부분 재질의 감도를 보다 높이고 전해 촉매제를 사용할수 있다면, 충분히 더 낮은 혹은 더 높은 pH를 확보할 수 있으며 또한 알카리 영역의 경우도 그럴 수 있으리라 예측된다. 2. 먹는물 수질기준에 따른 유속별 생산 전해수의 수질분석 및 미생물검사결과 세균학적인 검사의 경우 모든 검사과정에서 먹는물 기준 이하치를 나타내고 있으나 산성전해수의 경우 미생물학적인 검사에서 음성의 결과를 나타냈으나, 알카리수의 경우 중온성 세균수에 있어서는 먹는물의 수준은 될 수 없음을 알 수 있다. 3. 전해수빙과 담수빙 저장중 오징어의 일반성분과 VBN관찰 결과 수분 함량은 77.65%였으며 단백질 함량은 18.32%, 지질의 함량은 2.41%, 회분 함량은 1.62%로 나타났다. 오징어 빙장 직전 11.2mg/100g이었으며, 저장 초기에 모든 산성 전해수 빙장구에서 VBN 증가가 억제되었다.담수빙 법에서의 VBN 증가가 전해수빙중 산성수빙보다 훨씬 빠르게 진행되었으며 염기성수빙 보다는 느리게 진행되었다. 4. 저장중 오징어의 외관 및 색도 변화를 색차계로 저장시간별로 측정한 결과, 명도(L)는 저장시간별로 감소하는 경향이었으며, 적색도, 황색도는 저장방법에 따른 차이는 있었지만 저장기간에 따라서 증가하는 경향을 보였다. 즉, 저장시간별로 적색에서 녹색으로 청색에서 황색으로 색깔의 변화가 진행됨을 알 수 있었다. 백색도의 경우도 명도와 비슷한 경향 이었다.

예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획 (Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads)

  • 이경호;최병윤;주용진;이상렬;한승호
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석 (Simulation and Energy Cost Calculation of Encapsulated Ice Storage System)

  • 이경호;주용진;최병윤;김상준
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF