• Title/Summary/Keyword: iZone System

Search Result 227, Processing Time 0.027 seconds

Implementation of Disk I/O Sub System in Large Scale Video On Demand Sewer (대규모 VOD서버에서의 DISK I/O SUB SYSTEM의 구현)

  • 선창우;최경희;정기현
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1053-1056
    • /
    • 1999
  • Video On Demand servers generally require massive disk storages for storing many video data. Many researches have been done on the topics of efficient allocation of movies in disks. This paper, We describe efficient disk placement techniques and implement storage system with SCSI and PCI Bus interface for efficient data handling. This paper also proposes a logical zone reconstruction method for the SCAN data placement technique. The proposed method reconstructs physical zones into logical zones by split and merge operations.

  • PDF

A Study on Feature-Based Multi-Resolution Modelling - Part I: Effective Zones of Features (특징형상기반 다중해상도 모델링에 관한 연구 - Part I: 특징형상의 유효영역)

  • Lee K.Y.;Lee S.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.6
    • /
    • pp.432-443
    • /
    • 2005
  • Recent three-dimensional feature-based CAD systems based on solid or non-manifold modelling functionality have been widely used for product design in manufacturing companies. When product models associated with features are used in various downstream applications such as analysis, however, simplified and abstracted models at various levels of detail (LODs) are frequently more desirable and useful than the full detailed model. To provide multi-resolution models, the features need to be rearranged according to a criterion that measures the significance of the feature. However, if the features are rearranged, the resulting shape is possibly different from the original because union and subtraction Boolean operations are not commutative. To solve this problem, in this paper, the new concept of the effective zone of a feature is defined and identified using Boolean algebra. By introducing the effective zone, an arbitrary rearrangement of features becomes possible and arbitrary LOD criteria may be selected to suit various applications. Besides, because the effective zone of a feature is independent of the data structure of the model, the multi-resolution modelling algorithm based on the effective zone can be implemented on any 3D CAD system based on conventional solid representations as well as non-manifold topological (NMT) representations.

A Study on The Method of organizing Department Classroom in accordance with Managing Department System (교과교실제 운영에 따른 교과교실 공간배치 구성에 관한 연구)

  • Yoon, Hee-Cheol
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2011
  • Ministry of Education, Science And Technology, from 2009 to 2014, try to establish the setting of Department System in the Middle Schools and High Schools. They selected 45 Schools in 2009 and 61 Schools in 2010 for the Advanced Department System. I studied 2 High schools in 2009 and 3 High schools in 2010 of them, which located in GyeongGi-Do. I studied the Location of Department Classrooms, Teachers' Labs, Homebases and Resting Spaces of them. The conclusions are follows. 1) Most of them take Horizontal Zoning System in the Department Classrooms. 2) The Number of Teachers' Labs were increased in most of floors. On the other hand, most of Labs' Area were decreased. Every department Classroom Zone has one Teachers' Lab. 3) Every schools took much more spaces of Homebases and Resting Spaces than before. And various Resting Spaces using Corridors and Outdoors are prepared for students, those who moves every changing class time by the Department System.

A Study on Security Technology using Mobile Virtualization TYPE-I (모바일 가상화 TYPE-I을 이용한 보안 기술 연구)

  • Kang, Yong-Ho;Jang, Chang-Bok;Kim, Joo-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.1-9
    • /
    • 2015
  • Recently, with smart device proliferation and providing the various services using this, they have interested in mobile and Smart TV security. Smartphone users are enjoying various service, such as cloud, game, banking. But today's mobile security solutions and Study of Smart TV Security simply stays at the level of malicious code detection, mobile device management, security system itself. Accordingly, there is a need for technology for preventing hacking and leakage of sensitive information, such as certificates, legal documents, individual credit card number. To solve this problem, a variety of security technologies(mobile virtualization, ARM TrustZone, GlobalPlatform, MDM) in mobile devices have been studied. In this paper, we propose an efficient method to implement security technology based on TYPE-I virtualization using ARM TrustZone technology.

아트리움 공간에 있어서 화재에 의한 연기 유동에 관한 수치해석적 연구

  • 노재성;유홍선;정연태
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.43-48
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire modus: Zone model and Field model. The zone mode used is the CFAST(version 1.6) mode developed at the Building and Fire Research laboratories, NIST in the USA. The lied model is a self-developed fire field model based on Computational Fluid Dynamics(CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. A computational procedure for predicting velocity and temperature distribution in fro-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i. e. Zone model and Field model predicted similar results for Ire clear height and the smoke layer temperature.

  • PDF

A Study on the Effect of Exhaust Manifold Configuration on Engine Performance in a 4 Cylinder 4 Cycle Gasoline Engine (4실린더 4사이클 가솔린기관에서 배기계의 형상이 기관성능에 미치는 영향에 관한 연구)

  • 정수진;김태훈;조진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.751-767
    • /
    • 1994
  • Recent developments of S.I. engine, aiming to higher power, better fuel economy, lower air pollution and better driveability, have much focused on the importance of the role of computer simulation in engine research and development. In this point of view, improving engine performance requires finding some means to improve volumetric efficiency. Up to now there have been several attempts to optimize the intake and exhaust system of internal system of S.I. engine by computer simulation. There appear to be few studies available, however, of such simulation & experimental studies applied to the optimization of exhaust manifold configuration. In this study, gas exchange & power process of 4 cylinder S.I. Engine was studies numerically & experimentally, and governing equation of a one-dimensional unsteady compressible flow and combustion process were respectively solved by a characteristics method and 2-zone model. The aim of this study is to predict and investigate the influence of pressure wave interaction at the exhaust systems on engine performance with widely differing exhaust manifold configuration.

A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB (제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가)

  • Seol, Seok-Kyun;Kim, Joon-Hwan;Park, Min-Seok;Oh, Seung-Min;Ahn, Yong-Chul;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This study conducted Testing, Adjusting, and Balancing (TAB), which is a type of field performance evaluation experiment of a zone smoke-control system, at a railway underground transit passage installed with a zone smoke- control system to find problems and improvements for ensuring performance. TAB for the smoke control system was classified into several procedures, such as design data review, duct leakage test, field measurement of the airflow rate, velocity of the fan and duct, and a smoke test. Through the duct leakage test, the system leakage ratio was examined to prove the duct sealing. The iImprovement of the smoke control airflow problems due to the lack of fan static pressure loss was the secured performance. The performance of the smoke control fan was secured by improvements of the smoke control airflow rate problems caused by the loss of static pressure in the intake duct. The smoke test in the smoke control zone confirmed that the damper operating schedule subject was influenced by natural wind or train wind.

Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems (공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성)

  • Kim, J.D.;Jang, J.E.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

Groundwater Flow Modeling and Suggestion for Pumping Rate Restriction around K-1 Oil Stockpiling Base with Geological Consideration (지질조건을 고려한 K-1 비축기지 주변의 지하수 모델링과 양수량 제한구역 제안)

  • Moon, Sang-Ho;Kim, Kue-Young;Ha, Kyoo-Chul;Kim, Young-Seog;Won, Chong-Ho;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.169-181
    • /
    • 2010
  • This study aimed at simulating several responses to stresses caused by the ground water level variations around the K-1 oil stockpile. For this simulation, we considered the characteristic hydrogeological condition including the special occurrence of long and thick acidic dyke, which is regarded as the main geological structure dominating the ground water flow system at this study area. We activated twenty-four imaginary wells which are located in northern and southern area around central K-1 site. Each neighboring distance is altogether 300 m and whole distance between K-1 site and remote wells is 1,200 m. Through the modeling, we operated the long-term and continuous pumping tests and finally categorized five zones based on maximum pumping rates for the imaginary wells; zone I within 300 meter distance from K-1 site with a pumping rate of 50 $m^3/day$; zone II between 300 to 600 meter distance from K-1 site with a pumping rate of 75 $m^3/day$; zone III between 600 to 900 meter distance from K-1 site with 150 $m^3/day$; zone IV between 900 to 1,200 meter distance from K-1 site with 300 $m^3/day$; and zone V of acidic dyke area. At zone V, especially because of their possibility of high transmissivity for groundwater flow, it is necessary to control and restrict groundwater discharge.

Prediction Model for the Microstructure and Properties in Weld Beat Affected Brine : I. Trends in The Development of Model for the Prediction of Material Properties in the Weld HAZ (용접 열영향부 미세조직 및 재질 예측 모델링 : I. 용접부 재질 예측 모델 기술 개발 연구 동향)

  • Moon Joon-Oh;Lee Chang-Hee
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.17-26
    • /
    • 2005
  • HAZ (Heat Affected Zone) which occurs during welding thermal cycle has an important effect on the mechanical properties of the weld metal. So there were many efforts to develop the model which is able to predict the microstructure and mechanical properties in weld HAZ and lots of metallurgical models have reported since early 1940. These models are justifiable based on the reasonable assumption and analytical approach, but they also have limitation by interesting alloying system and assumption in each literature. Therefore, this study summaries the previous models for prediction of properties in weld HAZ. Then several issues to solve for developing the more reliable model were proposed.