• 제목/요약/키워드: hydrophilic acid

검색결과 375건 처리시간 0.021초

정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가 (Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique)

  • 손희종;황영도;류동춘;정철우;이건;손형식
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.

RESEARCH PAPERS : CHARACTERIZATION OF DISSOLVED ORGANIC MATTER IN A SHALLOW EUTROPHIC LAKE AND INFLOWING WATERS

  • 김용환;이선화
    • Environmental Engineering Research
    • /
    • 제7권2호
    • /
    • pp.93-101
    • /
    • 2002
  • The seasonal patterns of dissolved organic matter (DOM) in Lake Kasumigaura, a shallow, eutrophic lake, and serveral DOM sources in its catchment area were investigated. DOM was fractionated using three resin adsorbents into classes: aquatic humic substances (AHS=humic acid+fulvic acid), hydrophobic neutrals (HoN), hydrophilic acids (HiA), bases (BaS) and hydrophilic neutrals (HiN). The DOM produced significantly different fraction distributions depending on the origin of sample. AHS and HiA prevailed over AHS in the lake while AHS and HiA existed at almost the same concentration levels in the rivers. AHS seems to be a more dominant component in rever water than lake water. The dominance of organic acids was also observed in the DOM sources: forest stream (FS), plowed field percolate (PFP), domestic sewage (DS) and sewage treatment plant effluent (STPE).

Skin Permeation Enhancement of Drugs by Lipophilic and Hydrophilic Vehicles

  • Lee, Cheon-Koo;Goto, Shigeru
    • Journal of Pharmaceutical Investigation
    • /
    • 제25권3호spc1호
    • /
    • pp.43-51
    • /
    • 1995
  • The in vitro skin permeability of 16 drugs with a wide span of lipophilicity (log P ranging from -0,95 to 4.40) was evaluated with an ethanol/panasate 800 (tricaprylin, P-800) (40/60) lipophilic binary vehicle and an ethanol/water (60/40) hydrophilic binary vehicle with lauric acid, The skin permeability of the drugs was enhanced by the use of the ethanol/P-800 (40/60) binary vehicle or the ethanol/water (60/40) binary vehicle with lauric acid; permeation rate was increased and lag time' was decreased. The relationship between lipophilicity and skin permeation rate of the drugs showed parabolic shapes with their peaks at much greater hydrophilic range compared with other past references. In the in vivo skin absorption of theophylline using abdominal rat skin, the ethanol/P-800 (40/60)-7% (w/w) ethycellulose gel produced a good feature as a sustained-release preparation, and the ethanol/water (60/40)-3 % (w/w) HPMC gel with lauric acid showed the highest BA value. The results suggest that the lipophilicity of a drug is a main factor for prediction of the skin permeability of the drug and that the ethanol/P-800 (40/60) binary vehicle and ethanol/water (60/40) binary vehicle with lauric acid would be good candidates for clinical transdermal application of hydrophilic drugs.

  • PDF

Epi-xanthatin의 Side Chain 변환을 통한 새로운 반합성 유도체들의 합성 및 세포독성 (Synthesis of New Semisynthetic Analogs of Epi-xanthatin by Modification of the Side Chain and Their Cytotoxic Activity)

  • 백두종;안종웅;이정옥
    • 약학회지
    • /
    • 제49권1호
    • /
    • pp.68-73
    • /
    • 2005
  • Epi-xanthatin analogs containing hydrophilic substituents such as carboxylic acid, alcohol, morpholine, amino acid, and glucose derivatives were synthesized and their in vitro cytotoxicity and in vivo antitumor activity were evaluated. The target compounds were generally cytotoxic against tumor cell lines of human origin with $ED_{50}$ values of $0.1{\sim}30{\mu}g/ml$, except the highly hydrophilic analog 6 containing aspartic acid. Contrary to the potent cytotoxicity weakly hydrophilic analogs 2 and 8 were not active in vivo, or even toxic to the test animals. As a result, hydrophilic analog of epi-xanthatin did not show in vitro cytotoxicity and hydrophobic analogs did not show in vivo antitumor activity, thus it is presumed that amphiphilic analogs or those with medium hydrophilicity would exhibit the antitumor potency in vivo.

XAD 수지에 의한 친수성 및 소수성 수용성 유기탄소의 특성조사 (Study on Characterization of Hydrophilic and Hydrophobic Fractions of Water-soluble Organic Carbon with a XAD Resin)

  • 정재욱;김자현;박승식;문광주;이석조
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.337-346
    • /
    • 2011
  • 24-hr integrated measurements of water-soluble organic carbon (WSOC) in PM2.5 were made between May 5 and September 25, 2010, on a six-day interval basis, at the Metropolitan Area Air Pollution Monitoring Supersite. A macro-porous XAD7HP resin was used to separate hydrophilic and hydrophobic WSOC. Compounds that penetrate the XAD7HP column are referred to hydrophilic WSOC, while those retained by the column are defined as hydrophobic WSOC. Laboratory calibrations using organic standards suggest that hydrophilic WSOC includes lowmolecular aliphatic dicarboxylic acids and carbonyls with less than 4 or 5 carbons, amines, and saccharides. While the hydrophobic WSOC is composed of compounds of aliphatic dicarboxylic acids with carbon numbers larger than 4~5, phenols, aromatic acids, cyclic acid, and humic-like Suwannee River fulvic acid. Over the entire study period, total WSOC accounted for on average 48% of OC, ranging from 32 to 65%, and hydrophilic WSOC accounted for on average 30.5% (9.3~66.7%) of the total WSOC. Based on the previous results, our measurement result suggests that significant amounts of hydrophobic WSOC during the study period were probably from primary combustion sources. However, on June 9 when 1-hr highest ozone concentration of 130 ppb was observed, WSOC to OC was 0.61, driven by increases in the hydrophilic WSOC. This result also suggests that processes, such as secondary organic aerosol formation, produce significant levels of hydrophilic WSOC compounds that add substantially to the fine particle fraction of the organic aerosol.

Survival of surface-modified short versus long implants in complete or partially edentulous patients with a follow-up of 1 year or more: a systematic review and meta-analysis

  • Medikeri, Raghavendra Shrishail;Pereira, Marisca Austin;Waingade, Manjushri;Navale, Shwetambari
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.261-281
    • /
    • 2022
  • Purpose: Short implants are a potential alternative to long implants for use with bone augmentation in atrophic jaws. This meta-analysis investigated the survival rate and marginal bone level (MBL) of surface-modified short vs. long implants. Methods: Electronic and manual searches were performed for articles published between January 2010 and June 2021. Twenty-two randomized controlled trials (RCTs) comparing surface-modified short and long implants that reported the survival rate with at least 1 year of follow-up were selected. Two reviewers independently extracted the data, and the risk of bias and quality of evidence were evaluated. A quantitative meta-analysis was performed regarding survival rate and MBL. Results: The failure rates of surface-modified short and long implants differed significantly (risk ratio, 2.28; 95% confidence interval [CI], 1.46, 3.57; P<0.000). Long implants exhibited a higher survival rate than short implants (mean follow-up, 1-10 years). A significant difference was observed in mean MBL (mean difference=-0.43, 95% CI, -0.63, -0.23; P<0.000), favoring the short implants. Regarding the impact of surface treatment in short and long implants, for hydrophilic sandblasted acid-etched (P=0.020) and titanium oxide fluoride-modified (P=0.050) surfaces, the survival rate differed significantly between short and long implants. The MBL differences for novel nanostructured calcium-incorporated, hydrophilic sandblasted acid-etched, and dual acid-etched with nanometer-scale calcium phosphate crystal surfaces (P=0.050, P=0.020, and P<0.000, respectively) differed significantly for short vs. long implants. Conclusions: Short surface-modified implants are a potential alternative to longer implants in atrophic ridges. Long fluoride-modified and hydrophilic sandblasted acid-etched implants have higher survival rates than short implants. Short implants with novel nanostructured calcium-incorporated titanium surfaces, hydrophilic sandblasted acid-etched surfaces, and dual acid-etched surfaces with nanometer-scale calcium phosphate crystals showed less marginal bone loss than longer implants. Due to high heterogeneity, the MBL results should be interpreted cautiously, and better-designed RCTs should be assessed in the future.

The Optimization of Gel Electrolytes on Performance of Valve Regulated Lead Acid Batteries

  • An, Sang-Yong;Jeong, Euh-Duck;Won, Mi-Sook;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.998-1002
    • /
    • 2008
  • The gel electrolytes were prepared with sulfuric acid and phosphoric acid, where hydrophilic fumed silica was used as a gelling agent. The influences of gel electrolyte on performance of the valve regulated lead acid (VRLA) batteries were investigated employing capacity tests, electrochemical impedance spectroscopy and scanning electron microscopy. The initial capacities of the sulfuric gel VRLA batteries were higher than that of phosphoric gel VRLA batteries. The sulfuric gel VRLA battery using 1.210 specific gravity of sulfuric acid with hydrophilic fumed silica exhibited the highest capacity of 0.828Ah. In the impedance measurements, the ohmic and charge transfer resistances for the phosphoric gel VRLA batteries were higher thanthat of sulfuric gel batteries. The morphology of electrodes of phosphoric gel VRLA batteries were more deteriorated in the SEM image.

Bulk와 Emulsion System에서 유지에 대한 항산화제와 유화제의 항산화효과 (Antioxidative Activity of Some Antioxidants and Emulsifiers in Bulk and Emulsion Systems)

  • 김인원;신동화;장영상
    • 한국식품과학회지
    • /
    • 제31권4호
    • /
    • pp.1077-1083
    • /
    • 1999
  • 다른 유지상(bulk, oil-in-water)에 친수성 항산화제로서 gallic acid를 소수성 항산화제로서 ${\delta}-tocopherol$을 처리하고, HLB(hydrophilic lipophilic balance)에 따른 유화제를 처리하여 기질의 차이에 따른 항산화제와 유화제가 유지의 산화안정성에 미치는 정도를 실험하였다. 유지는 정제하지 않은 콩기름을 사용하였고 bulk상에서 12일 경과시 gallic acid를 첨가한 처리구의 유도기간이 Rancimat method로 측정시 4.13인데 비해 ${\delta}-tocopherol$을 첨가한 처리구의 유도기간은 1.18로 친수성 항산화제를 처리한 것이 3배 정도의 유지산화지연효과를 보였다. 또한 유화제의 처리에 있어서는 lecithin을 처리한 것의 유도기간이 5.07로 tween 20 처리 2.23, span 60의 경우 2.9인것에 비해 산화안정성면에서 우수하였다. 이와 같은 결과는 과산화물가와 공액이중산함량에서도 같은 경향을 보였다. Emulsion상(oil-in-water)에서도 bulk상과 같은 경향을 보였으며 이것은 emulsion상에 소수성 항산화제를 처리한 것이 유지 산화안정성면에서 더 효과적이라는 결과와는 차이가 있는데 기질의 차이, 즉 정제하지 않은 시판 콩기름을 사용한 것에 의한 차이인 것 같다. Emulsion상에서 유지방구의 크기는 저장하면서 모든 처리구에서 작아지는 경향을 보였으며, 이것은 유지방구의 크기가 작아지면서 표면적이 증가하고 따라서 공기와 접하는 면이 커지게 되므로 유지상은 안정해지나 산화는 더 촉진되므로 상의 안정과 산화안정성의 적절한 설정기준이 필요할 것으로 보인다.

  • PDF

Al(III) 응집제에 의한 하수처리수 중의 유기물 성상 변화 (Variation of dissolved organic matter in 2nd treated sewage water by Al(III) coagulant)

  • 김정선;한승우;김수현;강임석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.233-240
    • /
    • 2016
  • Control degree and property changes of dissolved organic matter (DOM) were conducted by coagulation of chemical treatment for 2 sewage treatment plants with different technical methods. As the result, SUVA value of the second treated water (supernatant of the second settling pond after biological treatment) was increased and DOC was reduced in comparison with supplied raw water. And, SUVA value and DOC were reduced by coagulation after coagulation treatment of the second treated water. Properties of dissolved organic matter for 2 sewage treatment plants's DOC were divided. As the result, there was lots of hydrophilic component with hydrophilicity in case of plant A. In case of the second treated water, Plant A showed fulvic acid with little molecular weight was reduced among the hydrophobic component with hydrophobicity, but numic acide with lots of molecular weight was increased. However, in case of plant B, both fulvic acid with little molecular weight and humic acid with lots of molecular weight were increased among the hydrophobic components with hydrophilicity. Before the operation of phosphorus facility, properties of dissolved organic matter after biodegradation with effluent water showed hydrophilic components were reduced and hydrophobic components were increased. However, after coagulation treatment of the second treated water, hydrophilic components and hydrophobic components were outstandingly decreased or increased. During the biodegradation after coagulation treatment, hydrophilic components were significantly decreased and hydrophobic components were increased.

이온화가스와 활성탄을 이용한 휴믹산 처리에 관한 연구 (The Humic Acid Treatment Characteristics by Ionized Gas and Combination with Activated Carbon)

  • 정팔진;이은주;김민정;조선영
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.72-77
    • /
    • 2004
  • Laboratory studies were carried out to find out the characteristics of humic acid treatment by activated carbon and ionized gas, In order to increase oxidation power of ionized gas for treating organic matter, we used granular activated carbon. By using $UV_{254}$, easy analysis method, we calculated humic acid concentration and $SCOD_{cr}$ concentration. For an initial concentration of humic acid, 10, 50 and 100ppm, the reaction rate constant by $UV_{254}$ was $8.98{\times}10^{-3}$/min, $5.62{\times}10^{-3}$/min and $4.8{\times}10^{-3}$/min respectively due to the same flow rate of ionized gas. When we added activated carbon to the ionized gas for humic acid treatment, the reaction rate constant increased in 4.13, 3.65 and 3.15 times. So, by using activated carbon in treating humic acid by ionized gas, oxidation power of organic matter by ionized gas was increased. The hydrophobic fraction constitutes 98% of organic matter for humic acid at the beginning. After the treatment using ionized gas for humic acid, the hydrophobic fraction decreased by 63~65% and the hydrophilic one increased by 35~37%. So, it was proved that the treatment increased the hydrophilic fraction in organic matter.