• Title/Summary/Keyword: hydro energy

Search Result 486, Processing Time 0.023 seconds

A Study on the Output Stabilization of the Nd:YAG Laser by the Monitoring of Capacitor Charging Voltage

  • Noh, Ki-Kyong;Song, Kum-Young;Park, Jin-Young;Hong, Jung-Hwan;Park, Sung-Joon;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.96-100
    • /
    • 2004
  • The Nd: YAG laser is commonly used throughout many fields such as accurate material processing, IC marking, semiconductor annealing, medical operation devices, etc., due to the fact that it has good thermal and mechanical properties and is easy to maintain. In materials processing, it is essential to vary the laser power density for specific materials. The laser power density can be mainly controlled by the current pulse width and pulse repetition rate. It is important to control the laser energy in those fields using a pulsed laser. In this paper we propose the constant-frequency current resonant half-bridge converter and monitoring of capacitor charging voltage. This laser power supply is designed and fabricated to have less switching loss, compact size, isolation with primary and secondary transformers, and detection of capacitor charging voltage. Also, the output stabilization characteristics of this Nd: YAG laser system are investigated. The test results are described as a function of laser output energy and flashlamp arc discharging constant. At the energy storage capacitor charges constant voltage, the laser output power is 2.3% error range in 600[V].

The Probabilistic Production Simulation with Energy Limited Units Using the Mixture of Cumulants Approximation (에너지 제약을 갖는 발전기를 고려한 경우의 Mixture of Cumulants Approximation법에 의한 발전시뮬레이션에 관한 연구)

  • 송길영;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1195-1202
    • /
    • 1991
  • This paper describes a newly developed method of production simulation by using the Mixture of Cumulant Approximation (MOCA). In this method, the load is modelled as random variable (r.v.) which can be interpreted in terms of partitioning the load into various categories. We can consider the load shape of multi-modal characteristics. The number of load category and demarcation points of each load category are calculated automatically by using interpolation and least square method. Each generating unit of a supply system is modelled as r.v. of unit outage capacity according to the number of unit outage subset. Since the computation burden of each subset's moments increases exponentially as units are convolved to the system, we further derive the specific recursive formulae. In simulating the energy limited units, hydro unit simulation is performed using Energy Invariance Property and the simulation of pumped storage unit is modelled as compulsory and economic operations. The proposed MOCA method is applide to the test systems and the results are compared with those of cumulant and Booth Baleriaux method. It is verified that the MOCA method is considerably reliable and stable both pathological and well behaved system.

Comparative Evaluation of Various Standard Methods in Leaching Test of Radioactive Waste Form (방사성고화체로부터의 $^{60}$ Co, $^{137}$ Cs 침출에 대한 표준시험법의 상호비교)

  • Kim, Ki-Hong;Ryu, Young-Gerl;Chung, Kyung-Ki;Hong, Kwon-Pyo;Lee, Nak-Hee;Jeong, Yi-Yeong;Koh, Duck-Joon;Kim, Heon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.93-103
    • /
    • 2003
  • IAEA, FT-04-020, and ANS 16.1, standard leaching test methods, were evaluated comparatively with their test results. Leaching index of $^{60}$ Co and $^{137}$ Cs by ANS 16.1 method for waste forms of paraffin and cement were above 6.0. Their leaching behavior were depending on the type of matrix and leachant. Leachability of $^{60}$ Co for cement waste form was higher in simulated seawater than do-mineralized water, and was higher in de-mineralized water for paraffin waste form. leachability of $^{60}$ Co was contrary to $^{137}$ Cs. Cumulative fraction leached of $^{60}$ Co was higher in order or IAEA > ANS > FT in a cement waste form.

  • PDF

Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions (고온 고압 조건하의 기포유동층 반응기에서의 입자 마모특성)

  • Moon, Jong-Ho;Lee, Dong-Ho;Ryu, Ho-Jung;Park, Young Cheol;Lee, Jong-Seop;Min, Byoung-Moo;Jin, Gyoung Tae
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.359-366
    • /
    • 2014
  • Attrition characteristics of PKM1-SU particles, $CO_2$ absorbents for pre-combustion $CO_2$ capture process, and FCC particles, catalytic particles for hydro cracking of crude oil, were investigated at high temperature and high pressure conditions. Particle attrition tests were executed at various kinds of temperature ($0-400^{\circ}C$) and pressure (0-20 bar) conditions in a cylinder type bubbling fluidized bed with 15.1 cm diameter, 120 cm height and 1 mm orifice-sparger tube. Attrited particles before and after tests were analyzed by BET, optical microscopy, and particle size analyzer. Effects of bed material height (solid inventory) and steam injection were also verified by using ASTM D5757-95, conventional attrition test method.

Feasibility Identification on Establishment of Solar Energy (Photovoltaic and Solar Heating) at the Environmental Basic Facilities in Busan (부산시 환경기초시설 내 태양에너지(태양광/태양열) 이용 시설 설치 타당성 확인)

  • Kim, Jiwon;Choi, Hyunho;Kim, Samuel;Park, Jeahong;Kim, Donghyun;Lee, Daeseon;Park, Sangtae;Kim, Gyusik;Yu, Jaecheul
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.73-85
    • /
    • 2015
  • With 12 environmental basic facilities (EBF) in Busan, each business place's present situation of the operation of new and renewable energy as well as the feasibility to establish additional systems of utilizing solar energy (photovoltaic power generation system [PPGS] and solar heating system [SHS]) were investigated. Currently, with the environmental basic facilities, the new and renewable energies (such as, waste heat, biogas, PPGS, SHS, and small hydro power) can produce 195 GWh per year as electric power unit. Among the energy sources, except waste heat, biogas (154 GWh/yr) appears as the highest. Next, PPGS is the second most widely used system and produces 5,560 MWh/yr at 11 business places. Through a field survey, it appears that 19 business places of total 27 places at 12 EBFs have good locational conditions and they need an introduction of PPGS. Through it, it is investigated that it would be possible to produce 5,311 MWh/yr and to reduce $2,348tCO_2/yr$. And, it is identified that SHS can be additionally introduced in only 4 EBFs. This can reduce energy cost as much as one ten million won/yr and green-house gas as much as $28tCO_2/yr$. A cost-benefic analysis shows that the use of governmental support or private investment can be the most efficient way, when PPGS and SHS are introduced in EBFs.

Computational Analysis of Parabolic Overtopping Wave Energy Convertor (포물선형 월류파력발전장치에 대한 수치해석)

  • Liu, Zhen;Hyun, Beom-Soo;Jin, Ji-Yuan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.273-278
    • /
    • 2009
  • Overtopping Wave Energy Convertor (OWEC) is an offshore wave energy convertor for collecting the overtopping waves and converting the water pressure head into electric power through the hydro turbines installed in the vertical duct which is fixed in the sea bed. The numerical wave tank based on the commercial computational fluid dynamics code Fluent is established for the corresponding analysis. Several incident wave conditions and shape parameters of the overtopping device are calculated. The straight line type and parabolic type of the sloping arm are compared in the optimal designing investigation of the overtopping characteristics and discharge for OWEC device. The numerical results demonstrate that the parabolic sloping arm is available for wave running up and the overtopping discharge increasing.

  • PDF

Assessment of Energy Self-sufficiency Ratio Based on Renewable Market Potentials for Unit of Local Government (기초지방자치단체별 보급 가능한 재생에너지 시장잠재량을 이용한 에너지 자립률 평가)

  • Kim, Jin-Young;Kang, Yong-Heack;Cho, Sangmin;Yun, Changyeol;Kim, Chang Ki;Kim, Ha-Yang;Lee, Seung Moon;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.137-151
    • /
    • 2019
  • This study estimated the available renewable market potential based on Levelized Cost Of Electricity and then assessed the renewable derived energy self-sufficiency for the unit of local government in South Korea. To calculate energy self-sufficiency, 1 km gridded market renewable generation and local government scale of final energy consumption data were used based on the market costs and statistics for the recent three years. The results showed that the estimated renewable market potentials were 689 TWh (Install capacity 829 GW, 128 Mtoe), which can cover 120% of power consumption. 55% of municipalities can fully replace the existing energy consumption with renewable energy generation and the surplus generation can compensate for the rest area through electricity trade. However, it was confirmed that, currently, 47% of the local governments do not fully consider all renewable energy sources such as wind, hydro and geothermal in establishing 100% renewable energy. The results of this study suggest that energy planning is decentralized, and this will greatly contribute to the establishment of power planning of local governments and close the information gap between the central government, the local governments, and the public.

The first KREDOS-EPR intercomparison exercise using alanine pellet dosimeter in South Korea

  • Park, Byeong Ryong;Kim, Jae Seok;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Kang, Yeong-Rok;Kim, HyoJin;Jang, Han-Ki;Han, Ki-Tek;Min, Jeho;Choi, Hoon;Kim, Jeongin;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2379-2386
    • /
    • 2020
  • This paper presents the results of the first intercomparison exercise performed by the Korea retrospective dosimetry (KREDOS) working group using electron paramagnetic resonance (EPR) spectroscopy. The intercomparison employed the alanine dosimeter, which is commonly used as the standard dosimeter in EPR methods. Four laboratories participated in the dose assessment of blind samples, and one laboratory carried out irradiation of blind samples. Two types of alanine dosimeters (Bruker and Magnettech) with different geometries were used. Both dosimeters were blindly irradiated at three dose levels (0.60, 2.70, and 8.00 Gy) and four samples per dose were distributed to the participating laboratories. Assessments of blind doses by the laboratories were performed using their own measurement protocols. One laboratory did not participate in the measurements of Magnettech alanine dosimeter samples. Intercomparison results were analyzed by calculating the relative bias, En value, and z-score. The results reported by participating laboratories were overall satisfactory for doses of 2.70 and 8.00 Gy but were considerably overestimated with a relative bias range of 10-95% for 0.60 Gy, which is lower than the minimum detectable dose (MDD) of the alanine dosimeter. After the first intercomparison, participating laboratories are working to improve their alanine-EPR dosimetry systems through continuous meetings and are preparing a second intercomparison exercise for other materials.

Implementation of Barcelona Basic Model into TOUGH2-MP/FLAC3D (TOUGH2-MP/FLAC3D의 Barcelona Basic Model 해석 모듈 개발)

  • Lee, Changsoo;Lee, Jaewon;Kim, Minseop;Kim, Geon Young
    • Tunnel and Underground Space
    • /
    • v.30 no.1
    • /
    • pp.39-62
    • /
    • 2020
  • In this study, Barcelona Basic Model (BBM) was implemented into TOUGH2-MP/FLAC3D for the numerical analysis of coupled thermo-hydro-mechanical (THM) behavior of unsaturated soils and the prediction of long-term behaviors. Similar to the methodology described in a previous study for the implementation of BBM into TOUGH-FLAC, the User Defined Model (UDM) of FLAC based on the Modified Cam Clay Model (MCCM) and the FISH function of FLAC3D were used to extend the existing MCCM module in FLAC3D for the implementation of BBM into TOUGH2-MP/FLAC3D. In the developed BBM module in TOUGH2-MP/FLAC3D, the plastic strains due to change in suction increase (SI) in addition to mean effective stress are calculated. In addition to loading-collapse (LC) yield surface, suction increase (SI) yield surface is changed by hardening rules in the developed BBM module. Several numerical simulations were conducted to verify and validate the implementation of BBM: using an example presented in the FLAC3D manual for the standard MCCM, simulation results using COMSOL, and experimental data presented in SKB Reports. In addition, the developed BBM analysis module was validated by simultaneously performing a series of modeling tests that were performed for the validation of the Quick tools developed for the purpose of effectively deriving BBM parameters, and by comparing the Quick tools and Code_Bright results reported in a previous study.

A Review on Measurement Techniques and Constitutive Models of Suction in Unsaturated Bentonite Buffer (불포화 벤토나이트 완충재의 수분흡입력 측정기술 및 구성모델 고찰)

  • Lee, Jae Owan;Yoon, Seok;Kim, Geon Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.329-338
    • /
    • 2019
  • Suction of unsaturated bentonite buffers is a very important input parameter for hydro-mechanical performance assessment and design of an engineered barrier system. This study analyzed suction measurement techniques and constitutive models of unsaturated porous media reported in the literature, and suggested suction measurement techniques and constitutive models suitable for bentonite buffer in an HLW repository. The literature review showed the suction of bentonite buffer to be much higher than that of soil, as measured by total suction including matric suction and osmotic suction. The measurement methods (RH-Cell, RH-Cell/Sensor) using a relative humidity sensor were suitable for suction measurement of the bentonite buffer; the RH-Cell /Sensor method was more preferred in consideration of the temperature change due to radioactive decay heat and measurement time. Various water retention models of bentonite buffers have been proposed through experiments, but the van Genuchten model is mainly used as a constitutive model of hydro-mechanical performance assessment of unsaturated buffers. The water characteristic curve of bentonite buffers showed different tendencies according to bentonite type, dry density, temperature, salinity, sample state and hysteresis. Selection of water retention models and determination of model input parameters should consider the effects of these controlling factors so as to improve overall reliability.