• Title/Summary/Keyword: hydro energy

Search Result 486, Processing Time 0.025 seconds

Radiation damage to Ni-based alloys in Wolsong CANDU reactor environments

  • Kwon, Junhyun;Jin, Hyung-Ha;Lee, Gyeong-Geun;Park, Dong-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.915-921
    • /
    • 2019
  • Radiation damage due to neutrons has been calculated in Ni-based alloys in Wolsong CANDU reactor environments. Two damage parameters are considered: displacement damage, and transmutation gas production. We used the SPECTER and SRIM computer codes in quantifying radiation damage. In addition, damage caused by Ni two-step reactions was considered. Estimations were made for the annulus spacers in a CANDU reactor that are located axially along a fuel channel and made of Inconel X-750. The calculation results indicate that the transmutation gas production from the Ni two-step reactions is predominant as the effective full power year increases. The displacement damage due to recoil atoms produced from Ni two-step reactions accounts for over 30% out of the total displacement damage.

A Survey on the M&V to guarantee the energy saving performance of ESCO (ESCO 에너지절약 M&V 방법의 선택 및 적용방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.123-129
    • /
    • 2014
  • ESCO industry should guarantee the energy saving performance with M&V such as developed countries. The application of the ESCO M&V is a necessary condition on energy saving performance. This study recommends a goal, direction, and order of application and suggests selection of M&V between option A, option B, option C, option D by energy conservation technology in Korea, with reference to the examples from IPMVP and applied in US and Japan. In the future, it is needed to study on the guideline for plan report and result report of M&V based on a goal, direction, and selection of M&V option.

Deformation Analysis of Solid-Liquid Coupled Structure using Explicit Finite Element Program (외연 유한요소 프로그램을 이용한 고체-액체 조합 구조물의 변형해석)

  • 최형연
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.150-155
    • /
    • 2000
  • In this study, deformation analysis for solid-liquid coupled structure has been performed using explicit finite element program In order to model the behavior of liquid, SPH (Smooth Particle Hydrodynamics) algorithm was adopted. Crash test and simulation for the hydro-type impact energy absorber were given as an example of industrial application. The obtained good correlation between the test results and simulation reveals that the proposed method could be used effectively for the structural analysis of solid-liquid coupled problems

  • PDF

Hydraulic Performance Characteristics of Kaplan Turbine (카프란수차의 수력학적 성능특성)

  • Lee C. H.;Park W. S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.443-446
    • /
    • 2005
  • The Kaplan turbine model has been tested and analyzed. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

Characteristics Analysis of Generator by Load Variation (부하변동에 따른 발전기 특성해석)

  • Kim, Jong-Gyeum
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.507-510
    • /
    • 2006
  • 본 논문은 신재생에너지의 한 분야로서 청정에너지인 소수력 발전시스템 운영시 수용가 부하의 변동에 따른 발전기의 특성변화를 해석한 것이다. 모의에 사용된 동기발전기-전동기가 부하의 변동에 따라 토크, 속도, 전류 등이 어떤 영향을 받는지 전자계 과도해석 프로그램을 사용하여 나타내었다.

  • PDF

Evaluation of renewable generation cost for designing the purchasing tariff system about renewable energy power (신.재생에너지전원의 발전차액지원제도 적용을 위한 발전원가 적용범위 산정)

  • Jo, I.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.840-842
    • /
    • 2005
  • Since 2001, Korea government has been purchasing the generation from renewable generation facilities with the higher incentive prices than market price in order to increase the penetration of renewable energies. Generally, the incentive purchase tariff is calculated on the base of the generation cost of renewable power facilities. This paper constructs the input data for economic analysis and evaluates the generation cost of PV, wind power, LFG and small hydro power using LCCA model.

  • PDF

Development of mini hydro power with use of the dam (수중보를 활용한 소수력 개발)

  • Kim, Sang-Seung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.412-414
    • /
    • 2007
  • 1982년 동력자원부의 ${\lceil}$소수력개발방안${\rfloor}$에 의해 민간인이 소수력발전사업에 참여할수 있는 제도가 만들어진 이후 초기단계에는 (1985년 ${\sim}$1995년) 많은 사업자가 소수력발전사업에 참여하여 성공도 하고 실패도 하였지만 1995년 이후에는 수자원공사, 농촌공사, 그리고 지방자치단체 만이 소수력발전소 건설에 참여하였다. 수중보를 이용한 민간인의 소수력 개발도 활성화 되기 바란다.

  • PDF

Research on the Effectiveness of Diagnostic Ultrasound Transmission Media (초음파진단 시 전파매질의 유용성)

  • Lee, Hye-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.324-330
    • /
    • 2015
  • When diagnostic ultrasounds are used, an ultrasonic transmission media is used to effectively transmit the ultrasonic energy. Types of ingredients of polymer hydro gel, emulsion, and oil gel were compared with commercialized products by measuring characteristics of ultrasonic transmission media such as skin lubricity, skin moisturizing, and dryness speed which were contained in each different media. The mean friction coefficient measured to investigate skin lubricity showed high in the agent containing a large amount of oil, whereas the mean friction coefficient of the low viscosity emulsion did not show a significant difference with that of the polymer hydro gel. The moisture evaporation measured to investigate the dryness speed of the agent showed highest in polymer hydro gel. This showed that the larger amount of oil it had, the less moisture evaporation occurred. For skin moisture measured to investigate moisturizing characteristics of skin, low viscosity emulsion showed high in moisture content, whereas it showed slowest reduction in moisture content. As a type of emulsion appropriately containing water and oil is superior in skin moisturizing and skin tenderness, it is expected to serve as a dosage form of new ultrasonic transmission media.

Structural Safety Evaluation by Analysis of Pressure Variation Characteristics of Small Hydro Power Hydraulic Turbine Blades in Sewage Treatment Plant (하수처리장 소수력 수차 블레이드의 압력변화 특성 분석을 통한 구조안전성 평가)

  • Park, Yoo-Sin;Kim, Ki-Jung;Youn, Byong-Don
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.126-131
    • /
    • 2017
  • Numerical analysis using commercial CFD code was carried out to develop the drag force type vertical axis hydraulic turbine for the improvement of the production efficiency of small hydro energy at low flow velocity condition. Blade pressure changes and internal flows were analyzed according to the presence or absence of the hydraulic turbine blade holes at flow velocity of less than 1.0~3.0 m/s. According to the numerical results, the pressure and flow velocity is severly affected by the flow velocity in turbine blade with no holes, while the influence of flow velocity is comparatively decreased in turbine blade with holes. It is also found that the pressure and flow velocity on the blade surface with holes are evenly distributed with no singular location and it is believed that forming a hole in the blade may be helpful in terms of structural safety.

Influencing Factors on Freezing Characteristics of Frost Susceptible Soil Based on Sensitivity Analysis (민감도 분석을 기반으로 한 시료의 동결 특성에 미치는 영향인자 분석)

  • Go, Gyu-Hyun;Lee, Jangguen;Kim, Minseop
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.8
    • /
    • pp.49-60
    • /
    • 2020
  • A fully coupled thermo-hydro-mechanical model is established to evaluate frost heave behaviour of saturated frost-susceptible soils. The method is based on mass conservation, energy conservation, and force equilibrium equations, which are fully coupled with each other. These equations consider various physical phenomena during one-dimensional soil freezing such as latent heat of phase change, thermal conductivity changes, pore water migration, and the accompanying mechanical deformation. Using the thermo-hydro-mechanical model, a sensitivity analysis study is conducted to examine the effects of the geotechnical parameters and external conditions on the amount of frost heave and frost heaving rate. According to the results of the sensitivity analysis, initial void ratio significantly affects each objective as an individual parameter, whereas soil particle thermal conductivity and temperature gradient affect frost heave behaviour to a greater degree when applied simultaneously. The factors considered in this study are the main factors affecting the frost heaving amount and rate, which may be used to determine the frostbite sensitivity of a new sample.