• 제목/요약/키워드: hydro energy

검색결과 490건 처리시간 0.027초

바이오에너지를 정의하는 지표들에 대한 고찰 (Index Evaluation to Define the Bioenergy as a Renewable Energy Resource)

  • 소진영;김현종;이재성;오경석
    • 한국응용과학기술학회지
    • /
    • 제30권3호
    • /
    • pp.480-487
    • /
    • 2013
  • Bioenergy is classified to one of the renewable energy resources such as solar, wind, hydro and tidal energies. It should be noted that all the renewable energies contribute to the reduction of greenhouse gases emission. In some cases, energy from wastes was also categorized as a renewable energy in our country even though it has only negligible effect on the emission reduction. In this paper, we tried to identify the bioenergy in order to follow the global indices of the renewable energy. The indices evaluated here were whether a resource is renewable, biogenic, biodegradable, combustible and organic. Biogenic and combustible were selected as the indices to identify the bioenergy. It was also suggested that combustible as an index can be exchangeable to organic.

관측 유량 자료를 이용한 소수력 잠재량 평가에 대한 사례연구 (Case Study : Assessment of Small Hydropower Potential Using Runoff Measurements)

  • 정성은;김진영;강용혁;김형수
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.43-54
    • /
    • 2018
  • In this study, we assessed dependency of small hydropower potentials on the two different runoff such as the estimated runoff based on the rainfall amounts and measured runoff. The hydpropower potentials were evaluated using actural power generations taken from Deoksong, Hanseok, and Socheon small hydropower plants over Han and Nakdong river basins, respectively. As a result of comparing the actual power generation amount with the potential amount based on the rainfall amount and the estimated amount based on the observed flow amount by each small hydroelectric power plant, the degree of latent small hydro energy by the observed flow was confirmed to be high. It is confirmed that the potential hydroelectric power generation rate is estimated to be about average 30%Point higher than the actual generation amount as a result of the measured flow rate rather than using the rainfall amount. Based on this, a method for improving the degree of the actual generation amount is proposed.

2차원 수리-역학적 연계 입자유동코드를 사용한 가스생산 유발지진 모델링: 네덜란드 그로닝엔 천연가스전에서의 지진 사례 연구 (Modelling Gas Production Induced Seismicity Using 2D Hydro-Mechanical Coupled Particle Flow Code: Case Study of Seismicity in the Natural Gas Field in Groningen Netherlands)

  • 윤정석;;;;;민기복
    • 터널과지하공간
    • /
    • 제33권1호
    • /
    • pp.57-69
    • /
    • 2023
  • 본 연구에서는 2차원 수리-역학적연계 개별요소모델링(DEM)을 사용하여 네델란드 그로닝엔(Groningen) 천연가스전 저류층의 유발지진을 모사하였다. 수치해석 코드는 ITASCA社의 상용프로그램인 PFC2D (Particle Flow Code 2D)를 사용하였으며 본 수치해석 연구에 적용하기 위해 수리-역학적 연계 모델 외 1) 비균질 저류층 압력분포 초기화, 2) 비선형 압력-시간이력 경계조건, 3) 국소 응력 분포 계산 등의 개별모듈을 추가개발, 적용하였다. 그로닝엔 가스전에 분포하는 복잡한 단층 형상을 포함하는 40 × 50 km2 크기의 2차원 모델을 생성하였고, 1960년부터 2020년까지 약 60년 동안의 가스생산, 즉 압 력저하로 인한 단층의 파괴거동을 모사하였다. 유발지진의 시공간적 발생을 수치해석모델로 재현하였고 그 발생 메커니즘을 규명하였다. 또한 저류층 압축으로부터 지표에서의 지반침하의 분포를 예측하였고 그로닝엔에서의 실측자료 사이에 유사성을 확인할 수 있었다. 이를 통해 본 연구에서 소개한 2차원 수리-역학적연계 개별요소모델링(DEM)의 복잡한 지질조건과 수리-역학적 연계 프로세스에 의한 단층거동을 구현할 수 있는 툴(tool)로서의 활용성을 확인하였다.

A Comparative Study on Effective One-Group Cross-Sections of ORIGEN and FISPACT to Calculate Nuclide Inventory for Decommissioning Nuclear Power Plant

  • Cha, Gilyong;Kim, Soonyoung;Lee, Minhye;Kim, Minchul;Kim, Hyunmin
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.99-106
    • /
    • 2022
  • Background: The radionuclide inventory calculation codes such as ORIGEN and FISPACT collapse neutron reaction libraries with energy spectra and generate an effective one-group cross-section. Since the nuclear cross-section data, energy group (g) structure, and other input details used by the two codes are different, there may be differences in each code's activation inventory calculation results. In this study, the calculation results of neutron-induced activation inventory using ORIGEN and FISPACT were compared and analyzed regarding radioactive waste classification and worker exposure during nuclear decommissioning. Materials and Methods: Two neutron spectra were used to obtain the comparison results: Watt fission spectrum and thermalized energy spectrum. The effective one-group cross-sections were generated for each type of energy group structure provided in ORIGEN and FISPACT. Then, the effective one-group cross-sections were analyzed by focusing on 59Ni, 63Ni, 94Nb, 60Co, 152Eu, and 154Eu, which are the main radionuclides of stainless steel, carbon steel, zircalloy, and concrete for decommissioning nuclear power plant (NPP). Results and Discussion: As a result of the analysis, 154Eu and 59Ni may be overestimated or underestimated depending on the code selection by up to 30%, because the cross-section library used for each code is different. When ORIGEN-44g, -49g, and -238g structures are selected, the differences of the calculation results of effective one-group cross-section according to group structure selection were less than 1% for the six nuclides applied in this study, and when FISPACT-69g, -172g, and -315g were applied, the difference was less than 1%, too. Conclusion: ORIGEN and FISPACT codes can be applied to activation calculations with their own built-in energy group structures for decommissioning NPP. Since the differences in calculation results may occur depending on the selection of codes and energy group structures, it is appropriate to properly select the energy group structure according to the accuracy required in the calculation and the characteristics of the problem.

하이드로포밍 공정을 이용한 범퍼 스테이 개발 (Analysis of hydroforming process for bumper stay)

  • 강부현;김봉준;류종수;손성만;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.233-236
    • /
    • 2003
  • A bumper comprises a bumper face, a bumper beam for distributing the load from the impacts applied to the bumper face and reinforcing the bumper, an absorber member interposed between the bumper face and the bumper beam, and a pair of bumper stays which secure the bumper beam to the vehicle body. A conventional bumper stay structure is assembled into several stamped parts, so several processes are needed and the structure is complicated. In this study the bumper stay is applied to the tubular hydroforming which is known to have several advantages such as the reduction of the number of the process and the part weight. The thickness distribution of the tube after hydroforming and the internal energy at the event of the a compression are mainly considered to evaluate the hydro-formability and energy absorption performance.

  • PDF

Engineering-scale Test for Validating the T-H-M Behavior of a HLW Repository: Experimental Set-up

  • Lee, Jae-Owan;Baik, Min-Hoon;Cho, Won-Jin
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.194-198
    • /
    • 2004
  • The thermo-hydro-mechanical (T-H-M) process is one of major issues in the performance assessment of a high level waste (HLW) repository. An engineering-scale test was planned and its experimental set-up has being installed, to validate the T-H-M behavior in the buffer of a reference disposal system. The experimental set-up consists of 4 major components: the confining cylinder with its hydration water tank, the bentonite block, the heating system, and the sensors and instruments. The monitoring and data acquisition system is employed to control the heater to maintain the temperature of $95^{\circ}C$ at the interface of the heater and bentonite blocks and to collect signals from sensors and instruments installed in the bentonite blocks.

  • PDF

강우자료 분석에 의한 소수력 발전소의 성능예측 (Performance Prediction of Small Hydropower Plant through Analyzing Rainfall Data)

  • 이철형;박완순;신동렬;정헌생
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.81-91
    • /
    • 1989
  • This study represents the method to predict the flow duration curve and primary design specifications of small hydropower plant at hydropower site through analyzing the monthly rainfall data. Weibull distribution was selected to characterize the rainfall data and Thiessen method was used to calculate monthly average flowrate at site. Application of these results, primary design specifications such as design flowrate, annual average load factor and utility factor, annual average hydropower density and annual electric energy production were estimated and discussed for surveyed site located in Daigi-ri, Kangwon province. And performance characteristic model of small hydro-power plant was applied to estimate these specifications.

  • PDF

고분자 전해질형 연료전지의 최적운전을 위한 전압-전류, 전류-전력 특성 연구 (A Study on the I-V and I-P Characteristics for Optimized Operation of PEMFC)

  • 정유라;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.112-116
    • /
    • 2010
  • Fuel cell as a renewable energy source is clean and has a lot of advantages. The source can solve energy crisis and environmental problems such as greenhouse effect, air pollution and the ozone layer destruction. This paper introduces hybrid system(hydro-Genius Professional, heliocentris) of solar cell and fuel cell. Also, this paper shows the I-P, V-I characteristics of fuel cells which are connected in parallel and series. From these results, we also found the maximum power was transferred at 0.5[${\Omega}$]. The terminal voltage was also decreased according to the current because of the internal resistance. The power transfer in series was two times than that in parallel.

자동 동조 퍼지 제어기를 이용한 수력 발전소 조속기 연구 (A Study on the Hydraulic Turbine Governor using Automatic Tuning Fuzzy Controller)

  • 이선근;이원용;신동열;권오석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.265-268
    • /
    • 1992
  • The control performances of a fuzzy controller depend on its control rules, I/O membership functions, and scaling factors. Scaling factors are very important to adjust control parameters to the process which is to be controlled. For tuning the sealing factors, trial and error method is used in conventional fuzzy controller, which is very difficult and time consuming. This paper proposes a tuning method of scaling factors based on the concept of tuning rules for the conventional Pl controller parameters. The proposed automatic tuning fuzzy controller was evaluated by computer simulations. Good results have been obtained for the small hydro power plant.

  • PDF

Shape Effect of Inlet Nozzle and Draft Tube on the Performance and Internal Flow of Cross-Flow Hydro Turbine

  • Choi, Young-Do;Son, Sung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.351-357
    • /
    • 2012
  • Small hydropower is a reliable energy technology to be considered for providing clean electricity generation. Producing electrical energy by small hydropower is the most efficient contribution to renewable energy. Cross-flow turbine is adopted primarily because of its simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the effect of inlet nozzle shape on the performance and internal flow of a cross-flow turbine for small hydropower by CFD analysis. Moreover, the shape effect of draft tube has been investigated according to modified shapes of the length and the diffuse angle. The results show that relatively narrow and converging inlet nozzle shape gives better effect on the performance of the turbine.