• 제목/요약/키워드: hydraulic shock loading

검색결과 7건 처리시간 0.019초

호기성 고정생물막반응기에서 동일 질량부하의 수리학적 및 농도충격부하시 반응의 비교 (Comparison of Aerobic Fixed-film Process Response to Quantitative and Hydraulic Shock for the Same Increases in Mass Loading)

  • 안미경;이규훈;박태주
    • 한국환경과학회지
    • /
    • 제3권3호
    • /
    • pp.285-296
    • /
    • 1994
  • The objective of this study was to examine and compare to transient response to quantitative and hydraulic shocks which produce equal changes in mass rate of organic feed in aerobic fixed-film process. The general experimental approach was to operate the system at several growth rates under steady-state(pre-shock) conditions, then to apply step changes during day 3 in dilution rate(hydraulic shock) , or feed concentration(Quantitative shock) at the same organic mass loading rate. Performance was assessed in both the transient state and the new steady-state (post- shock). Shock load of different type did not produced equivalent disruptions of effluent quality for equal increases in mass loading rate. Based on effluent concentrations, a hydraulic and a Quantitative shock at the same mass loading caused equal increase in total effluent COD, but the increase was primarily a result of suspended solids the hydraulic shock and COD in the quantitative shock. The time which effluent COD came to peak values were about 32~48 hours at the low organic loads and 52 ~ 72 hours at the high organic loads, respectively A quantitative shock produced a much greater increase in effluent COD than did a hydraulic shock at the same mass loading. Mean and peak values of effluent concentration weve increased in 2.8~4.2 times at low organic loading rate, 5.2~6.6 times at the high organic loading rate, respectively. Key words : Aerobic fixed-film reactor, Quantitative shock, hydraulic shock, mass loading rate.

  • PDF

활성슬러지공정의 수리학적 충격부하 반응 (Hydraulic Shock Load Response of Activated Sludge Process)

  • 황규대;김민호;고새봄;조철휘
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.67-78
    • /
    • 1997
  • The objective of study was to examine to transient response of hydraulic shock loading in activated sludge process for treatment of municipal sewage. The general experiment approach was to operate the system under steady-state(pre-shock), then to apply step changes during 24hours in fourfold hydraulic shock loading at the same organic loading. Performance was assessed in both the transient state and the new steady-state(post-shock). Three bench scale activated sludge reactors were operated to investigate the effect of fourfold hydraulic shock loading on TSS and COD removal efficiency. In activated sludge reactors operated with 13hours and 7hours of HRT, effluent quality of all reactors was not changed for few effects, and also showed no foaming and no sludge bulking. Those results are the same as sludge withdrawn reactors. The effect of fourfold hydraulic shock loading on the activated sludge reactors operated with 3hours of HRT was most severe. The effluent quality was deteriorated significantly and generate foaming in reactors. Less than 24hours after the fourfold shock loading applied, the activated sludge system seemed to attain a new steady-state condition as show by effluent.

  • PDF

단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가 (Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading)

  • 홍기호;장덕
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가 (Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch)

  • 홍기호;장덕;한상배
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.

이상혐기공정의 축산폐수 공공처리시설 적용 가능성에 관한 실험적 연구 (A Study on the Evaluation of Two-Phase Anaerobic Process for Public Livestock Wastewater Treatment Plant)

  • 오성모;김문호;배윤선;박철휘
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.331-339
    • /
    • 2007
  • The purpose of this study was to investigate the biodegradability and performance of organic removal and methane production rate when treating piggery wastewater using a pilot scale two-phase anaerobic system operated up to a volumetric rate of $10m^3/day$. The pilot scale two-phase anaerobic process is consisted of a continuous-flow stirred-tank reactor (CFSTR) for the acidification phase and an Upflow Anaerobic Sludge Blanket reactor (UASB) for the methanogenesis. The acidogenic reactor played key roles in reducing the periodically applied shock-loading and in the acidification of the influent organics. The acidogenic CFSTR was operated at organic loading rates (OLR) between 1.8 and $14.4kgCOD/m^3{\cdot}day$, and the UASB reactor was operated between 0.5 and $5.6kgCOD/m^3{\cdot}day$. A stable maximum biogas production rate was $81m^3/day$ and the methane conversion rate of the organic matter varied from 0.30 to $0.42L\;CH_4/g\;COD_{removed}$(0.40) at hydraulic retention time (HRT) above 3.5days. The methane contents ranged from 73 to 82% during the experimental period. It is known that most of the removed organic matter was converted to methane gas, and the produced biogas might be high quality for its subsequent use.

고농도 황산염을 함유한 폐수의 혐기성 처리시 메탄균의 효율 향상을 위한 연구 (Improvement of Methanogenic activity in the Anaerobic Treatment of Wastewater with High Sulfate)

  • 신항식;오세은
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.47-54
    • /
    • 1996
  • UASB reactor was operated for treating wastewater containing high sulfate to assess their performance, competition between sulfate-reducing bacteria(SRB) and methane-producing bacteria(MPB), and the change in the characteristics of microbial granules according to change of hydraulic retention time(HRT) in the reactor. The reactor was fed with a synthetic moderate strength wastes(glucose, 2000 mgCOD/l) containing high sulfate($2400mgSO_4{^{2-}}/l$). The organic loading rate(OLR) ranged from 1.5 to 3.0 gCOD/l.d as HRT maintained 15 to 30 hrs in the stage I. The COD removal efficiency was between 80 to 92%. During this period, methane yield rapidly decreased from 0.3 to 0.1 1 $CH_4$/gCODremoved. While sulfide concentration in the effluent increased from 80 to 200 mgS/l. This indicates that SRB becomes dominant over MPB at a relatively long HRT in the excess sulfate. When OLR of reactor maintained from 5 to 8 gCOD/l.d in the stage II, methane yield increased from 0.1 to 0.17 1 $CH_4$/gCODremoved regardless of decrease of COD removal efficiency. This indicates that SRB is more sensitive to the change of a short HRT than MPB. In the competition between SRB and MPB, about 30% of the removed COD was utilized by SRB at HRT of 30 hrs during the start-up period, while about 73% was used by SRB at HRT of 15hrs at the final step of second experimental stage. Whereas after shock exposure of OLR about 62% was utilized by SRB at HRT of 5hrs. It indicates that SRB is strongly suppressed by the wash-out of significant dispersed SRB since a large electron flow is distributed to the MPB. In addition, the granulation in the presence of high sulfate is unfavoured at a long HRT because of substrate transport limitations into MPB like Methanothrix spp. which is an important factor in the composition of the granules. Accordingly, granule sizes in the UASB reactor decreased with time due to weak network frame of granules by the decreased activity of MPB.

  • PDF

Study on failure behaviors of mixed-mode cracks under static and dynamic loads

  • Zhou, Lei;Chen, Jianxing;Zhou, Changlin;Zhu, Zheming;Dong, Yuqing;Wang, Hanbing
    • Geomechanics and Engineering
    • /
    • 제29권5호
    • /
    • pp.567-582
    • /
    • 2022
  • In the present study, a series of physical experiments and numerical simulations were conducted to investigate the effects of mode I and mixed-mode I/II cracks on the fracture modes and stability of roadway tunnel models. The experiments and simulations incorporated different inclination angle flaws under both static and dynamic loads. The quasi-static and dynamic testing were conducted by using an electro-hydraulic servo control device and drop weight impact system (DWIS), and the failure process was simulated by using rock failure process analysis (RFPA) and AUTODYN software. The stress intensity factor was also calculated to evaluate the stability of the flawed roadway tunnel models by using ABAQUS software. According to comparisons between the test and numerical results, it is observed that for flawed roadways with a single radical crack and inclination angle of 45°, the static and dynamic stability are the lowest relative to other angles of fractured rock masses. For mixed-mode I/II cracks in flawed roadway tunnel models under dynamic loading, a wing crack is produced and the pre-existing cracks increase the stress concentration factor in the right part of the specimen, but this factor will not be larger than the maximum principal stress region in the roadway tunnel models. Additionally, damage to the sidewalls will be involved in the flawed roadway tunnel models under static loads.