• Title/Summary/Keyword: hydraulic retention time

Search Result 354, Processing Time 0.029 seconds

Optimization for SBR Process of Two-Sludge Type (Two-sludge 유형 SBR 공정의 최적 운영 조건 도출)

  • Ryu, Hong-Duck;Hwang, Jae-Sik;Kim, Keum-Yong;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.229-234
    • /
    • 2007
  • In the present work, the sequencing batch reactor process of two-sludge type was optimized. The effects of solid retention time, hydraulic retention time, length of biosorption phase and temperature variation were investigated, respectively. In the T-N removal, the long solid retention time was favored. It was speculated that SCOD biosorption efficiency was higher in long solid retention time than in short solid retention time. In the comparison of hydraulic retention time, the removal efficiency of $NH_4^+-N$ and T-N were almost same in all applied hydraulic retention times which were 8 hr, 10 hr and 15 hr. It was observed that there was no need to have the hydraulic retention time more than 20 min in biosorption phase for enhancement of T-N removal efficiency. An experimental comparison of removal efficiencies with different temperature conditions was carried out. Decrease of temperature didn't affect the performance of the process, however, phosphorus removal efficiency was a little higher at low temperature than high temperature. Consequently, the process developed in this study was much amenable to wastewater treatment which was conducted in the low temperature and high loading rate.

Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater (육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향)

  • Park, Noh-Back
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.

A Study on the Limiting Factors in Nitrogen Removal with Fixed Biofilm Process (고정생물막 공법을 이용한 질소제거에 있어서 제한요인에 관한 연구)

  • 지용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.63-68
    • /
    • 1996
  • This study was to discuss limiting factors influenced on the removal efficiencies of nitrogenous compounds investigated using the polypropyrene media which was to attach microorganism in order to apply the fixed-biofilm process. The main limiting factors are the hydraulic retention time (HRT), C/N ratio, $COD/NO_{3}-N$ ratio and temperature. The hydraulic retention time HRT were 6, 8, 10, 12 hrs and the C/N ratio range was 2.5-9.5. The $COD/NO_{3}-N$ ratio range was 3.2-21.9 and the temperature were 15, 20, 25, 30, $35^{\circ}C$, respectively. The results of this study are summerized as follows. 1. Hydraulic retention time (HRT) to obtain removal efficiencies of T-N higher than 85% had to be 10 hrs above. 2. The removal efficiencies of T-N decreased at C/N ratio from 6.2 to 4.8 in this anoxic-contact aeration system. 3. Denitrification rate decreased at $COD/NO$_{3}$-N$ ratio from 8.0 to 5.0 4. As temperature increased, removal efficiencies of T-N increased.

  • PDF

Substrate Removal Condition in Activated Sludge Process of Wastewater from Acetaldehyde Manufacturing Plant (Acetaldehyde폐수의 활성오이법에 의한 기질제거조건)

  • 금영일;금두조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.1
    • /
    • pp.107-116
    • /
    • 1993
  • This study is conducted to investigate treatability by activated sludge process for wastewater from acetaldehyde manufacturing plant. The optimum hydraulic retention time in aeration tank for removal of high strength substrate were measured. The removal efficiency were checked out by hydraulic retention time : 35hr., 40hr. and 45hr., respectively. $COD_{Cr}$, like substances were removed in all hydraulic retention time zone directed for efficiency, but non-biodegradable substances were remained. $COD_{Cr}$ biomass loading was 0.81kg $COD_{Cr}/kgMLVSS$ . day at 35hr. of retention time, 0.34 kg$COD_{Cr}$/kg MLVSS . day at 40hr., and O.l9kg$COD_Cr$/kgMLVSS . day at 45hr. And the mean $COD_{Cr}$, removal efficiency was 65.5%, 81.6% and 83.0%, respectively. And also $COD_{Cr}$, volume loading was 1.01kg$COD_{Cr}/m^3$ day, 0.87kg$COD_{Cr}/m^3$ - day, and 0.79kg$COD_{Cr}/m^3{\cdot }$day, respectively. The basic design parameter obtained is as fallows. The value of Specific substrate removal rate coefficient (k), Yield coefficient(Y) and Decay coefficient($k_d$) was $0.0013day^{-1}$, $0.505kgMLVSS/kgCOD_{Cr}$ and $0.040day^{-1}$, respectively.

  • PDF

The Optimum Design of Suspended Growth Systems (부유성 미생물을 이용한 생물처리법의 최적 설계)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1011-1019
    • /
    • 2000
  • The purpose of this study is to examine the basis of design condition of existing treatment processes, namely, Extended Aeration Process, Conventional Activated Process, High Rate Aeration Process and Modified Aeration Process, by clarifying the correlations of influent wastewater concentration, hydraulic retention time, food-to-microorganism ratio and sedimentation of sludge, as well as to ascertain the feasibility of design, regardless of the existing design condition. In particular, this study made a priority investigation of hydraulic retention time and sludge sedimentation, because sludge sedimentation is the main factor$^{1)}$ which determines the operating conditions of existing treatment processes. Therefore, it is generally known that in case exceeds the sphere of design presented for each treatment, sludge bulking may occur. The results of Lesperance's test$^{1)}$, which formed the basis of design, showed the sphere of loading without security of sludge sedimentation, as in Fig. 1. The reason for sludge bulking in a certain condition, as above, is due to failure in application of optimum loading corresponding to each retention time by employing a few operating condition, which proved to be consecutively workable after years of trials and failures by Lesperance, for test conditions. However, the result of this test showed that in case of proper maintenance of loading. sludge sedimentation can be ensured under 120 SVI. Therefore, this study suggested hydraulic retention time and its corresponding optimum loading, and identified the hydraulic retention time as a determinant of sludge sedimentation. And. on the basis of these findings, this study suggested the feasiblity of UHR(Ultra High Rate), a new operating process, exceeding several times the applicable loading value of High Rate Aeration Process under one hour retention time which has not yet applied to the existing treatment processes.

  • PDF

Sewage Treatment Using Water Hyacinth (Eichhornia crassipes) and Watercress (Oenanthe Javanica) (부레옥잠과 미나리를 이용한 연속식 하수처리에서 COD, N 및 P의 제거)

  • Park, Jin-Sick
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • This study was carried out to investigate sewage treatment efficiencies using water hyacinth (Eichhornia crassipes) and watercress (Oenanthe Javanica). In the hyacinth system about 30% of COD introduced was removed during 2 days of hydraulic retention time, and about 30$\sim$50% of COD was removed in the watercress system during 1.2$\sim$2 days of hydraulic retention time. Therefore, COD loading of $76\sim170$ kg $COD/ha{\cdot}day$ was removed during 2$\sim$3 days of hydraulic retention time at the 0.18 $m^2$ area in the water hyacinth-watercress continuous system. Also 40$\sim$50% of N and P in the sewage were removed in the tested water hyacinth-watercress system Although COD, N and P concentrations in the final effluent were still higher than the limits of waste discharge, applicability of this waste water treatment system should be further investigated as an alternative method far small scale sewage treatments.

Anaerobic treatment of red-bean processing wastewater in a sludge bed reactor (슬러지반응기에서 팥가공폐수의 철기성 처리)

  • 안재동;금재우;홍종향
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.29-37
    • /
    • 1994
  • Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.

  • PDF

Decolorization kinetics and characteristics of the azo dye acid red 18 in MSBR system at various HRTs and SRTs

  • Zonoozi, M. Hasani;Moghaddam, M.R. Alavi;Maknoon, R.
    • Membrane and Water Treatment
    • /
    • v.5 no.4
    • /
    • pp.281-293
    • /
    • 2014
  • The present work aimed to study the decolorization kinetics and characteristics of a selected azo dye under the influence of two key operational parameters including hydraulic retention time (HRT) and solid retention time (SRT). The decolorization efficiency and the two important criteria of k and normalized k (k/MLSS) were evaluated in lab-scale membrane sequencing batch reactors (MSBRs) at various HRTs of 48, 24 and 16 h (with constant SRT) and in addition, at various SRTs of infinity, 40 and 10 d (with constant HRT). According to the obtained results, both zero and first-order kinetics were properly fitted the decolorization profiles of the selected azo dye in all of the applied HRTs and SRTs. Increase of both HRT and SRT positively affected the decolorization efficiency. More MLSS concentrations corresponded to the lower HRTs and the higher SRTs resulted in higher decolorization rate constants (k). However, the effect of reducing the HRT was not compensated by increase of the MLSS concentration in order to reach higher decolorization efficiency. In addition, increase of the decolorization efficiency, as a consequence of the higher MLSS concentrations at longer SRTs, was restrained by decrease of the time-limited decolorization capability of biomass (represented by normalized k). Evaluation of both k and normalized k is suggested in order to have a more precise study on the decolorization kinetics and characteristics.

Sludge Returned CMAS에 의한 전기부속품제조공장 폐수처리

  • 김남천;이시진
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.4
    • /
    • pp.427-433
    • /
    • 1997
  • Sludge Returned CMAS process was applied to treat the wastewater from electric accessory manufacturing company while this type of wastewater was usually treated by chemical process. This result show that the removal rate of TCOD was about 70-80% regardless of hydraulic retention time, On the contrary, the removal rate of BOD was abtained in a range of 77-92% depending on hydraulic retention time. In order to remove more than 80% of organic materials with the proposed process, the F/M ratio should be maintained below 0.17. In this case, the calculated value of organic removal rate, Km, was calculated to be 1.26 hr$^{-1}$, and the ratio of cell synthesis/total energy was 0.32 and 0.26 for COD and BOD base, respectively. The yield coefficient was calculated to be 0.242 and the half velocity coefficient was 0.3 hr$^{-1}$. The value of endogenous respiration coefficient was 0.02 hr$^{-1}$. The measured effluent BOD concentration, MLSS concentration in aeration tank, oxygen uptake rate, and sludge production were matched relatively well with the calculated values using above coefficients, In order to optimize the dewatering of sludge, the hydraulic retention time was recommended to be 15. 6 hrs. These results indicate that the wastewater from an eletric accessory manufacturing company can be treated safely with a biological process.

  • PDF

Treatment of Tapioca Starch Wastewater By Anaerobic Digestion Coupled With Membrane Separation Process (혐기성 소화 및 막분리에 의한 Tapioca 전분의 폐수처리)

  • ;S. Vigneswaran
    • KSBB Journal
    • /
    • v.6 no.2
    • /
    • pp.135-141
    • /
    • 1991
  • This study thus looks into two treatment processess : i) Anaerobic digester coupled with hollow fibre membrane unit. Treatment of starch waste with anaerobic digester-membrane system was studied. $0.17\m^2$ area of hollow fibre membrane unit of known pore size was immersed into laboratory-scale anaerobic digestion system. The pore size of membrane was varied from 0.03 to $\0.15mu$m. The hydraulic retention time of anaerobic digester was varied from 1.5 to 10 days. The effect of hydraulic retention time on treatment efficiency was significant while effect of membrane size was not significant. The gas production was about 0.74㎥/kg COD treated. The COD removal efficient was about 80-95% depending on the hydraulic retention time. ii ) Crossflow ultrafiltration as post treatment to anaerobic filter. The effluent from anaerobic filter, which had a total COD in the range of 4,500-5,200 mg/L was treated by crossflow ultrafiltration units. The study conducted with different membrane pore size indicated that membrace with 1,000,000 molecular weight cut-off size gave a higher COD removal efficiency in the range of 83-87% while giving a study flux of $120-130 L/\m^2$.h. A study was conducted to see the long term clogging effect of membrane also.

  • PDF