• 제목/요약/키워드: hydraulic head

검색결과 378건 처리시간 0.027초

레이디얼 피스톤 펌프의 피스톤 접촉 메커니즘 개발 (Development of piston contact mechanism for radial piston pump)

  • 함영복;차재곤;김대명;공태우;윤소남;안국영;권병수
    • 유공압시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 2010
  • This paper presents the experimental results of the radial piston type oil pump with new mechanism for a metal diaphragm hydrogen compressor. Generally, metal diaphragm type hydrogen compressor systems are operated by oil hydraulic power. In this system an oil compensating pump has been demanded to compensate for a leakage oil head chamber. The metal diaphragm type hydrogen compressor consists of an oil compensating pump, commonly used hydraulic piston pump and driven by main crank shaft. The radial piston type oil compensating pump with new rolling contacted piston mechanism is developed and experimented. The developed piston element of the radial piston pump consists of piston, steel ball, return spring, two check valves, eccentric cam and ball racer. In this study, designed 4 type pistons as and orifice hole. Operating characteristics and pressure ripple characteristics are tested under no load to 60bar loaded with every 20bar increasing step and pressure ripple and flow rate are experimentally investigated.

  • PDF

사축식 유압 펌프의 마찰손실 해석 (Analysis on the frictional loss of a bent-axis type hydraulic piston pump)

  • 홍예선;도윤호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1548-1553
    • /
    • 2003
  • The design of a high speed axial piston pump for hydrostatic transmission systems requires specific understanding on where and how much its internal frictional and flow losses are generated. In this study, the frictional loss of a bentaxis type hydraulic piston pump was analyzed in order to find out which design factors influence the mechanical efficiency most significantly. To this end, the friction coefficients of the sliding components were experimentally identified by a specially constructed tribometer. Applying them to the three-dimensional dynamic model of the pump presented by Doh and Hong [1], the friction torques generated by the sliding components such as piston head , bearing and valve plate were theoretically computed. The accuracy of the computed results was confirmed by the comparison with the experimentally measured mechanical efficiency. In this paper, it is shown that the viscous friction on the valve plate and the drive shaft bearing is the primary sources of the frictional losses of the bent-axis type pump, while the friction forces on the piston contribute to them only slightly.

  • PDF

돌망태 보 통과류의 비선형적 흐름 특성에 관한 실험적연구 (Experimental study on non-linear throughflow characteristics of rockfill gabion weir)

  • 한일영;이재정;김규범
    • 한국수자원학회논문집
    • /
    • 제53권10호
    • /
    • pp.861-870
    • /
    • 2020
  • 자갈 입자로 구성된 다공성매질에서는 유속이 증가하여 레이놀즈수가 커지게 되면 흐름은 Darcy의 영역을 벗어나게 된다. 본 연구는 인공함양 유역의 소하천에 설치예정인 돌망태 보의 채움재를 통과하는 비선형적인 흐름특성을 규명하기 위하여 자갈칼럼과 돌망태모형을 이용한 투수실험을 수행하였다. 칼럼실험을 통하여 공극유속과 수리경사의 관계식과 계수를 결정하고, 수리평균반경과의 상관관계식을 제안하였다. 제안식으로 부터 계산된 공극유속과 공극유량은 돌망태모형 투수실험의 측정치와 잘 일치하였다.

양방향펌프와 편로드실린더에 의한 리프터의 구동에 관한 연구 (Study for the Actuation of Lifter by the Bi-Directional Pump and Single-Rod Cylinder)

  • 이성래;김제민
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.139-145
    • /
    • 2007
  • The motion of single-rod cylinder is typically controlled by the directional control valve. In some case, the hydraulic system should be energized by the man power and at the same time the motion of a cylinder is controlled manually. It may be confusing for a man to do two things at the same time. The solution is to make up the closed hydraulic circuit with the bi-directional pump and single-rod cylinder without using a directional control valve. In the case of single-rod cylinder, the flows at the rod side and head side are so different that several valves should be installed to make the motion of single-rod cylinder possible. The hydraulic system is composed of a bi-directional pump, a single-rod cylinder, pilot operated check valves, a check valve and a counter balance valve for the purpose of actuating the lifter. The characteristics of a suggested system are analysized mathematically and numerically.

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.

홍적지대에 있어서의 지하수의 3차원적 유동-3차원 정상류모델에 의한 지하수 유동해석 (Three-dimensional groundwater water flow in an upland area-groundwater flow analysis by steady state three-dimensional model)

  • 배상근
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1987년도 제29회 수공학연구발표회논문초록집
    • /
    • pp.113-122
    • /
    • 1987
  • A numerical simulation technique of three-dimensional finite difference model is developed to study the groundwater flow system in Dcjima, an upland area which faces Kasumigaura Lake. For general perspectives of the groundwater flow system, a steady state three-dimentional model is simulated. For the sedimentary mud formations which are found in the representative formation, three situations of hydraulic conductivity are considered, representing an isotropic condition and situations where the horizontal permeability is equal to 10 times and 100times of the vertical one. The finite difference grid used in the simulation has 60x50x30=90,000 nodes. A converged solution with a tolerance of 0.001 meter of hydraulic head is set. Having determined the flow net by using a steady state three-dimensional model. the results for the three cases of hydraulic conductivity are compared with the results of tracer methods (Bae and Kayane 1987) With the aid of four representative vertical cross-sections, groundwater flow systems in the study area are assumed. Water balances for the three cases indicate very good agreement between total recharge and discharge in each case Analyses of groundwater flow system based on the tritium concentrations and water quality measurements (Bae and Kayane 1987) are confirmed by the numerical simulation and the results obtained by these two methods appeared to be in close agreement.

  • PDF

국가지하수 관측망의 양수시험 자료 해석을 통한 대수층 특성 분석

  • 전선금;구민호;김용제;강인옥
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.487-491
    • /
    • 2004
  • For tile hydrogeological data of the National Groundwater Monitoring Wells(NGMW), a statistical analysis is made to reveal aquifer characteristics of the country. Results of the pumping and recovery test are classified into 4~5 types by the pattern of drawdown and residual drawdown curves. The analysis of aquifer characteristics shows that the hydraulic conductivity of alluvial aquifers is greater than that of fractured-rock aquifers. The hydraulic conductivity of alluvial aquifers slightly increases as the distance to the discharge area decreases. 77.5% of the NGMWs, where the distance to the discharge area is more than 100m, shows the constant head boundary. This result suggests that the fractured and the alluvial aquifers are fairly interconnected, and water can be supplied from one aquifer to tile other where pumping tests are performed. It is analyzed that the wells showing the impermeable boundary are influenced by small scale of aquifers, poor aquifer transmissivities, and impermeable layers.

  • PDF

디퓨져를 이용한 튜블러형 상반전 수차의 CFD 성능해석 (CFD Analysis of a Counter-rotating Tubular Type Micro-Turbine with Diffuser)

  • 이낙중;박지훈;황영호;김유택;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2011
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this study, in order to acquire design data of counter-rotating tubular type micro-turbine, output power, head, and efficiency characteristics due to the diffuser.

  • PDF

수차발전기 축계의 진동해석 (Vibration Analysis of Hydraulic Turbine-Generator Rotor)

  • 김용한;손병구;최병근;양보석;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.250-254
    • /
    • 1998
  • Pump-storage power plants, which pumps water from the lower reservoir to the upper reservoir using the extra electronic power at night and generates the electronic power in the daytime, are more increasing. Currently it has a tendency to be high-head large-capacity machines. So in the processing of design, we need to know the vibration characteristics of pump-turbine shaft system sufficiently. In this paper, we developed the computer programs for analyzing pump-turbine shaft system considering magnetic force of generator, hydraulic force at runner, dynamic characteristics of guide bearings and the effect of add mass of water. And the superiority of this program was verified by applying it to the real model and calculating high quality critical speed, natural mode and unbalance response.

  • PDF

소수력용 수차의 종류 및 설치 예 (Classification and Installation Cases of Small Hydraulic Turbine)

  • 최영도;김유택;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.503-506
    • /
    • 2006
  • Recently, small hydropower attracts attention because of its clean renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of small hydropower and it is necessary to study for the effect ive turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the small hydropower turbine. Therefore, this study is trying not only, to classify the type of current operating turbines installed in the domestic power plants and turbines supplied in Japan by Japanese manufacturer but also, to examine the practical turbine type and installation site to extract the small hydropower energy effectively.

  • PDF