• 제목/요약/키워드: hybrid-switching

검색결과 310건 처리시간 0.022초

Analysis of Hybrid Converter with Wide Voltage Range Operation

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1099-1107
    • /
    • 2019
  • A soft switching converter with wide voltage range operation is investigated in this paper. A series resonant converter is implemented to achieve a high circuit efficiency with soft switching characteristics on power switches and rectifier diodes. To improve the weakness of the narrow voltage range in LLC converters, an alternating current (ac) power switch is used on the primary side to select a half-bridge or full-bridge resonant circuit to implement 4:1 voltage range operation. On the secondary-side, another ac power switch is adopted to select a full-wave rectifier or voltage-doubler rectifier to achiever an additional 2:1 output voltage range. Therefore, the proposed resonant converter has the capacity for 8:1 (320V~40V) wide output voltage operation. A single-stage hybrid resonant converter is employed in the study circuit instead of a two-stage dc converter to achiever wide voltage range operation. As a result, the study converter has better converter efficiency. The theoretical analysis and circuit characteristics are verified by experiments with a prototype circuit.

Method of DASH segments into a MMTP stream for switching contents under a hybrid broadcasting environment

  • Kang, Jeonho;Kang, Dongjin;Kim, Kyuheon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권12호
    • /
    • pp.5981-5997
    • /
    • 2017
  • Advanced Television Systems Committee (ATSC) produced ATSC 2.0 standard, which has been used for a HD/SD digital broadcasting service with MPEG-2 Transport Stream (TS) as a delivery protocol. Recently, users might want to consume multimedia services without being constrained by transport network. However, MPEG-2 TS is not suitable protocol for IP network. Thus, ATSC has enacted ATSC 3.0 standard, which is designed for a hybrid service through a conversion of both broadcasting and broadband channels. The ATSC 3.0 specifies delivery protocols as MPEG Media Transport (MMT) for a broadcasting environment and Dynamic Adaptive Streaming over HTTP (DASH) for a broadband. However, it seems difficult to combine broadcast and broadband for hybrid broadcasting, and it is difficult to synchronize media data between MMT and DASH. This paper suggests various new service scenarios to be brought up by a hybrid broadcasting, ATSC 3.0, and also proposes a stable mechanism for switching contents between different delivery protocols such as MMT and DASH.

A Cascaded Hybrid Multilevel Inverter Incorporating a Reconfiguration Technique for Low Voltage DC Distribution Applications

  • Khomfoi, Surin
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.340-350
    • /
    • 2016
  • A cascaded hybrid multilevel inverter including a reconfiguration technique for low voltage dc distribution applications is proposed in this paper. A PWM generation fault detection and reconfiguration paradigm after an inverter cell fault are developed by using only a single-chip controller. The proposed PWM technique is also modified to reduce switching losses. In addition, the proposed topology can reduce the number of required power switches compared to the conventional cascaded multilevel inverter. The proposed technique is validated by using a 3-kVA prototype. The switching losses of the proposed multilevel inverter are also investigated. The experimental results show that the proposed hybrid inverter can improve system efficiency, reliability and cost effectiveness. The efficiency of proposed system is 97.45% under the tested conditions. The proposed hybrid inverter topology is a promising method for low voltage dc distribution and can be applied for the multiple loads which are required in a data center or telecommunication building.

Optimum Hybrid SVPWM Technique for Three-level Inverter on the Basis of Minimum RMS Flux Ripple

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.413-430
    • /
    • 2019
  • This paper presents an optimum hybrid SVPWM technique for three-level voltage source inverters (VSIs). The proposed hybrid SVPWM technique aims to minimize total harmonic distortion (THD). A new parameter is introduced to incorporate the heterogeneous nature of switching sequences of SVPWM technique. The proposed hybrid SVPWM technique is implemented on a low-cost PIC microcontroller (PIC18F452) and verified experimentally with a 2 KVA three-phase three-level insulated gate bipolar transistor-based VSI. Optimum switching sequence results in the three-level inverter configuration are demonstrated. The proposed hybrid SVPWM technique improves the THD performance by 17.3% compared with the best available three-level SVPWM technique.

A Double-Hybrid Spread-Spectrum Technique for EMI Mitigation in DC-DC Switching Regulators

  • Dousoky, Gamal M.;Shoyama, Masahito;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.342-350
    • /
    • 2010
  • Randomizing the switching frequency (RSF) to reduce the electromagnetic interference (EMI) of switching power converters is a well-known technique that has been previously discussed. The randomized pulse position (RPP) technique, in which the switching frequency is kept fixed while the pulse position (the delay from the starting of the switching cycle to the turn-on instant within the cycle) is randomized, has been previously addressed in the literature for the same purpose. This paper presents a double-hybrid technique (DHB) for EMI reduction in dc-dc switching regulators. The proposed technique employed both the RSF and the RPP techniques. To effectively spread the conducted-noise frequency spectrum and at the same time attain a satisfactory output voltage quality, two parameters (switching frequency and pulse position) were randomized, and a third parameter (the duty ratio) was controlled by a digital compensator. Implementation was achieved using field programmable gate array (FPGA) technology, which is increasingly being adopted in industrial electronic applications. To evaluate the contribution of the proposed DHB technique, investigations were carried out for each basic PWM, RPP, RSF, and DHB technique. Then a comparison was made of the performances achieved. The experimentally investigated features include the effect of each technique on the common-mode, differential-mode, and total conducted-noise characteristics, and their influence on the converter’s output ripple voltage.

3상 3.3kV/220V 6kVA 모듈형 반도체 변압기의 프로토타입 개발 (Prototype Development of 3-Phase 3.3kV/220V 6kVA Modular Semiconductor Transformer)

  • 김재혁;김도현;이병권;한병문;이준영;최남섭
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1678-1687
    • /
    • 2013
  • This paper describes a prototype of 3-phase 3.3kV/220V 6kVA modular semiconductor transformer developed in the lab for feasibility study. The developed prototype is composed of three single-phase units coupled in Y-connection. Each single-phase unit with a rating of 1.9kV/127V 2kVA consists of a high-voltage high-frequency resonant AC-DC converter, a low-voltage hybrid-switching DC-DC converter, and a low-voltage hybrid-switching DC-AC converter. Also each single-phase unit has two DSP controllers to control converter operation and to acquire monitoring data. Monitoring system was developed based on LabView by using CAN communication link between the DSP controller and PC. Through various experimental analyses it was verified that the prototype operates with proper performance under normal and sag condition. The system efficiency can be improved by adopting optimal design and replacing the IGBT switch with the SiC MOSFET switch. The developed prototype confirms a possibility to build a commercial high-voltage high-power semiconductor transformer by increasing the number of series-connected converter modules in high-voltage side and improving the performance of switching element.

AC/DC 병가선로의 개폐서지 과전압 해석 (Analysis of Switching Surge Over-voltage in AC/DC Hybrid Transmission Lines)

  • 유성수;신구용;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.459-466
    • /
    • 2022
  • 개폐서지는 전력시스템에서 발생하는 과전압 현상 중의 하나이며 변전소의 차단기 등 개폐장치의 동작이나 송전선로의 고장으로 인해 발생한다. 특히 송전선로의 절연설계를 위하여 개폐서지의 피크를 산정하는 것은 매우 중요하고 AC/DC 병가선로의 안정적인 운영을 위한 절연협조의 기본적인 검토항목이다. 본 논문에서는 새로운 AC/DC 병가구조의 전력시스템에 대한 상정해석을 위하여 AC 765kV와 DC ±500kV Bi-Pole 시스템이 조합된 송전선로를 대상으로 하였다. 일반적으로 교류 송전시스템의 절연설계를 위한 비정상적인 과전압은 외부과전압으로 낙뢰에 의한 과전압과 내부과전압으로 개폐에 의한 과전압을 고려한다. 직류 송전시스템의 경우에는 개폐에 의한 과전압 보다 송전선로의 중간에서 지락고장이 발생하면 인접한 정상선로에 유기되는 내부과전압을 개폐서지라하며 직류송전선로에 유기되는 가장 큰 일시적인 과전압을 의미한다. 본 논문의 연구목적으로 구성된 선로에 대하여 EMTDC 소프트웨어를 사용하여 모의하였으며, 다양한 AC/DC 혼합 형태에 대한 개폐과전압의 영향을 검토하였다.

A Parallel Hybrid Soft Switching Converter with Low Circulating Current Losses and a Low Current Ripple

  • Lin, Bor-Ren;Chen, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1429-1437
    • /
    • 2015
  • A new parallel hybrid soft switching converter with low circulating current losses during the freewheeling state and a low output current ripple is presented in this paper. Two circuit modules are connected in parallel using the interleaved pulse-width modulation scheme to provide more power to the output load and to reduce the output current ripple. Each circuit module includes a three-level converter and a half-bridge converter sharing the same lagging-leg switches. A resonant capacitor is adopted on the primary side of the three-level converter to reduce the circulating current to zero in the freewheeling state. Thus, the high circulating current loss in conventional three-level converters is alleviated. A half-bridge converter is adopted to extend the ZVS range. Therefore, the lagging-leg switches can be turned on under zero voltage switching from light load to full load conditions. The secondary windings of the two converters are connected in series so that the rectified voltage is positive instead of zero during the freewheeling interval. Hence, the output inductance of the three-level converter can be reduced. The circuit configuration, operation principles and circuit characteristics are presented in detail. Experiments based on a 1920W prototype are provided to verify the effectiveness of the proposed converter.

하이브리드 광학 네트워크-온-칩에서 병렬 라우팅에 관한 연구 (A Study on the Parallel Routing in Hybrid Optical Networks-on-Chip)

  • 서정택;황용중;한태희
    • 대한전자공학회논문지SD
    • /
    • 제48권8호
    • /
    • pp.25-32
    • /
    • 2011
  • 네트워크-온-칩(Networks-on-Chip, NoC)은 고도로 복잡해지고 있는 다중 프로세서 시스템-온-칩(Multi-Processor System-on-chip, MPSoC)에서의 버스 트래픽 문제를 해결할 핵심기술이나 전통적인 전기적 상호 연결 구조로는 머지않아 대역폭 및 전력소비 등의 한계에 직면할 것으로 예상된다. 이러한 문제를 해결하기 위해 광학적 상호연결과 전기적 상호연결을 같이 사용하는 하이브리드 광학 NoC기술이 최근 활발히 연구되고 있다. 대부분의 하이브리드 광학 NoC에서 전기적인 연결은 웜홀 스위칭(Wormhole switching)과 deterministic 알고리즘인 X-Y 라우팅 알고리즘을 사용하며, 광학적 버스 기반 데이터 전송을 위한 경로 설정 및 광학 라우터 설정을 한다. 광학적 연결에서는 서킷 스위칭(Circuit switching) 방식을 사용하며, 미리 설정된 경로 및 라우터를 이용하여 payload 데이터만 전송을 하게 된다. 그러나 기존에 발표된 하이브리드 광학 NoC같은 경우에는 한 번에 하나의 경로에서만 데이터를 전송 할 수 있다는 단점을 가지고 있어 성능 향상에 한계가 있다. 본 논문에서는 하이브리드 광학 NoC에서 동시에 여러 경로를 이용하여 데이터를 전송하기 위해 전기적인 연결에서 서킷 스위칭 방식과 적응적(adaptive) 알고리즘을 이용하는 새로운 라우팅 알고리즘을 제안하며, 적응적 알고리즘의 문제점인 livelock을 제거할 수 있는 방법 또한 제안한다. 모의실험은 전기적인 NoC, 그리고 웜홀 스위칭 방식의 기존 하이브리드 광학 NoC와 비교 수행 하였다. 그 결과 제안된 방식은 기존 하이브리드 광학 NoC에 비해 60%의 throughput 증가, 그리고 전기적 NoC와 비교했을 때 65%의 전력 감소를 보였다.

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.