• 제목/요약/키워드: hybrid-composite beam

검색결과 128건 처리시간 0.023초

하이브리드 보의 휨성능에 관한 실험적 연구 (An Experimental Study on the Flexural Strength of Hybrid Beam)

  • 홍성걸;양동현;임병호;류재천
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.398-401
    • /
    • 2006
  • This study investigates the behaviour of Hybrid Beam with reinforced concrete encased steel center and reinforced concrete end. Two types of encased steel shape and two sections are examined in this study. Test results showed that H-Hybrid beam is stronger than Honey-comb Hybrid beam, and the behaviour of composite beam embedded steel at the elastic state is same as that of simple beam.

  • PDF

춤이 작은 신형상 고성능 하이브리드 합성보의 휨성능 평가 (Bending Performance Evaluation of Hybrid Composite Beam with Low Depth and New Shape)

  • 김성배;조성현;오광수;전용한;최영한;김상섭
    • 한국강구조학회 논문집
    • /
    • 제28권3호
    • /
    • pp.151-162
    • /
    • 2016
  • 본 연구는 합성보와 하이브리드보의 장점을 활용한 신형상 하이브리드 합성보의 형상을 개발하였으며, 그 중 춤이 작은 형상의 휨성능을 검증하기 위해 12개의 휨 실험체를 제작하여 단조가력 실험을 진행하였다. 휨성능 실험결과, 공칭하중에 대한 실험체 최대하중의 비는 평균 1.24배로 안정적인 내력을 확보하였으며, 합성보의 내력평가는 기존 합성보 내력평가식(KBC 2009)을 적용 가능한 것으로 판단된다. 또한 하부강판에 고강도강($F_y=650MPa$) 적용 시 소재의 기계적 특성 및 구조성능에 대한 충분한 사전검토가 필요할 것으로 판단된다.

Effect of the GFRP wrapping on the shear and bending Behavior of RC beams with GFRP encasement

  • Ozkilic, Yasin Onuralp;Gemi, Lokman;Madenci, Emrah;Aksoylu, Ceyhun;Kalkan, İlker
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.193-204
    • /
    • 2022
  • The need for establishing the contribution of pultruded FRP encasements and additional FRP wraps around these encasements to the shear strength and load-deflection behavior of reinforced concrete beams is the main motivation of the present study. This paper primarily focuses on the effect of additional wrapping around the composite beam on the flexural and shear behavior of the pultruded GFRP (Glass Fiber Reinforced Polymer) beams infilled with reinforced concrete, taking into account different types of failure according to av/H ratio (arch action, shear-tension, shear-compression and pure bending). For this purpose, nine hybrid beams with variable shear span-to-depth ratio (av/H) were tested. Hybrid beams with 500 mm, 1000 mm, and 1500 mm lengths and cross-sections of 150x100 mm and 100x100 mm were tested under three-point and four-point loading. Based on the testing load-displacement relationship, ductility ratio, energy dissipation capacity of the beams were evaluated with comprehensive macro damage analysis on pultruded GFRP profile and GFRP wrapping. The GFRP wraps were established to have a major contribution to the composite beam ductility (90-125%) and strength (40-75%) in all ranges of beam behavior (shear-dominated or dominated by the coupling of shear and flexure). The composite beams with wraps were showns to reach ductilities and strength values of their counterparts with much greater beam depth.

Strengthening of steel-concrete composite beams with composite slab

  • Subhani, Mahbube;Kabir, Muhammad Ikramul;Al-Amer, Riyadh
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.91-105
    • /
    • 2020
  • Steel-concrete composite beam with profiled steel sheet has gained its popularity in the last two decades. Due to the ageing of these structures, retrofitting in terms of flexural strength is necessary to ensure that the aged structures can carry the increased traffic load throughout their design life. The steel ribs, which presented in the profiled steel deck, limit the use of shear connectors. This leads to a poor degree of composite action between the concrete slab and steel beam compared to the solid slab situation. As a result, the shear connectors that connects the slab and beam will be subjected to higher shear stress which may also require strengthening to increase the load carrying capacity of an existing composite structure. While most of the available studies focus on the strengthening of longitudinal shear and flexural strength separately, the present work investigates the effect of both flexural and longitudinal shear strengthening of steel-concrete composite beam with composite slab in terms of failure modes, ultimate load carrying capacity, ductility, end-slip, strain profile and interface differential strain. The flexural strengthening was conducted using carbon fibre reinforced polymer (CFRP) or steel plate on the soffit of the steel I-beam, while longitudinal shear capacity was enhanced using post-installed high strength bolts. Moreover, a combination of both the longitudinal shear and flexural strengthening techniques was also implemented (hybrid strengthening). It is concluded that hybrid strengthening improved the ultimate load carrying capacity and reduce slip and interface differential strain that lead to improved composite action. However, hybrid strengthening resulted in brittle failure mode that decreased ductility of the beam.

Hybrid Vibration Control of Smart Laminated Composite Beams using Piezoelectric and Viscoelastic Material

  • Kang, Young-Kyu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2003
  • Active control of flexural vibrations of smart laminated composite beams has been carried out using piezoceramic sensor/actuator and viscoelastic material. The beams with passive constrained layer damping have been analyzed by formulating the equations of motion through the use of extended Hamilton's principle. The dynamic characteristics such as damping ratio and modal damping of the beam are calculated for various fiber orientations by means of iterative complex eigensolution method. This paper addresses a design strategy of laminated composite under flexural vibrations to design structure with maximum possible damping capacity.

신형상 U형 하이브리드 합성보의 내화성능에 관한 연구 (Fire Resistance of U-shape Hybrid Composite Beam)

  • 김성배;김상섭;유덕수;최승관
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.379-388
    • /
    • 2013
  • 본 연구에서는 신형상 U형 하이브리드 합성보의 내화성능평가를 실시하였다. 내화성능평가는 세라믹계의 뿜칠재와 내화페인트로 구분하여 내화시험을 수행하였다. 시험 변수는 피복재의 종류(뿜칠재와 페인트)와 내화시간(2시간, 3시간), 하중가력 유무(재하와 비재하), 뿜칠재 두께 등이다. 내화성능평가 합성보는 기존 철골보로 인정을 받은 제품에 비해 내화성능이 향상되는 것을 확인할 수 있다. 그러나 내화성능 향상에 대한 정량적인 평가는 합성보 형상과 관련한 다양한 변수가 조합되므로 지속적인 검토가 필요할 것으로 판단된다.

신형상 U형 하이브리드 합성보의 휨성능에 대한 연구 (Study on the Flexible Strength of U-shape Hybrid Composite Beam)

  • 김성배;김상섭;이원록;김정연;이승배;유덕수;김대회
    • 한국강구조학회 논문집
    • /
    • 제24권5호
    • /
    • pp.521-534
    • /
    • 2012
  • 본 연구에서는 합성보의 특징을 활용하고, 일부 고강도강 적용이 가능한 단면을 개발하여 이에 대한 기초연구를 실시하였다. 본 논문은 그 첫 번째로 단위부재인 합성보의 휨성능을 실험을 통해 평가하였다. 실험결과를 통해 기존 합성보의 공칭강도 산정식 적용여부를 검토하였고, 각 구성부재를 주요변수로 하여 실험하였다. 실험결과 신형상 U형 합성보의 내력평가는 콘크리트 압축강도와 강재의 인장강도에 의한 우력모멘트로 소요모멘트에 저항하는 것으로 평가하는 것이 적합하며, 보 춤 및 강판 두께에 비례하여 내력이 안정적으로 증가하였으며, 연성거동을 하는 것으로 나타났다.

고강도강재를 적용한 비대칭 하이브리드 합성보의 휨거동 실험 (Flexural Testing of Asymmetric Hybrid Composite Beams Fabricated from High-strength Steels)

  • 전수찬;한규홍;이철호;김진원
    • 한국강구조학회 논문집
    • /
    • 제29권3호
    • /
    • pp.217-228
    • /
    • 2017
  • 본 연구에서는 고강도강재를 적용한 비대칭 하이브리드 합성보의 휨성능을 실물대 실험을 통하여 평가하였다. 합성보의 웨브와 상부플랜지에는 일반강재(SM400, SM490)를 적용하고 하부플랜지는 상부플랜지에 비해 상대적으로 크게 제작하여 비대칭 단면으로 적용한 후 일반강재(SM520) 및 고강도강재(SM570, HSA800)를 각각 적용하였다. 본 연구의 주요 목적은 비대칭 하이브리드 합성보의 휨성능 평가 및 설계지침의 개발이다. 실험결과 하부플랜지에 일반강재를 적용한 실험체의 경우 $Dp/Dt{\leq}0.15$를 만족시킬 시 우수한 휨강도와 연성능력을 발현하는 것을 확인하였다. 반면 하부플랜지에 고강도강재가 적용된 실험체의 경우 휨내력의 증가로 인한 슬래브의 수평전단력 증가가 예상치 못한 슬래브 종방향 전단파괴를 발생시켜 소성강도에 도달하지 못하였다. 따라서 고강도강재를 적용한 비대칭 하이브리드 합성보의 경우 설계단계에서 슬래브 수평전단강도 확보가 필수적이다.

교량용 강ㆍ콘크리트 합성 바닥판 단위모델의 부재별 거동 특성 (Behavior of Members in the Unit Model of Steel-Concrete Hybrid Deck for Bridges)

  • 정광회;정연주;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.493-498
    • /
    • 2003
  • The 3D nonlinear analysis for steel-concrete hybrid deck is carried out by utilizing 2D plane interface element. The effect of the slip occurred between steel and concrete can be modeled by this element. This analysis focuses on not only global behavior of steel-concrete hybrid deck but also local behaviors of members of it such as lower steel plate, I-beam, and concrete which are varied by slip modulus. In this analysis, it was founded that the limit slip modulus could classify the states of steel-concrete hybrid deck into three parts such as full-composite, partial-composite, and non-composite, considering the behavior of lower steel plate, I-beam, and concrete at the mid span and the support as well as the yield load and ultimate load of it.

  • PDF