• 제목/요약/키워드: humidity supply

검색결과 172건 처리시간 0.027초

부족팽창된 습공기 초음속 제트에 관한 연구 (Study of the Moderately Under-Expanded Supersonic Jet of Moist Air)

  • 백승철;김희동;권순범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2121-2126
    • /
    • 2003
  • Supersonic free jets discharging from an orifice or a nozzle have long been research subject with a number of engineering applications and have mainly been investigated using dry air or other gas without any condensation effects. The major characteristics of those supersonic jets are now well known in terms of jet pressure ratio and ratio of specific heats of gas. Recently, the supersonic jets of superheated steam or moist air are being used in many industrial applications, in which case is expected that the condensation effects might alter the fundamental structure of the dry air jet. The present study aims to investigate the supersonic moist air jet and to clarify the condensation effects on the jet structure. An experiment is carried out using an indraft wind tunnel facility. The relative humidity of moist air is controlled at the nozzle supply, and the jet pressure ratio is varied to obtain the moderately under expanded flows at the exit of the nozzle. It is found that the relative humidity of moist air can change the diameter and location of Mach Disk.

  • PDF

초음속 습공기 제트에서 발생하는 마하디스크의 거동 (Behaviors of Mach Disk in Underexpanded Supersonic Moist Jet)

  • 백승철;김희동;권순범
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.87-90
    • /
    • 2003
  • 압축성 유동장의 주된 특징은 유동장의 형성과정에 의존한다는 것은 잘 알려져 있다. 본 연구의 목적은 비평형 응축을 수반하는 초음속 제트유동장의 발달에 미치는 제트의 시간이력을 조사하는 것이다. 특히 초음속 습공기 제트에서 마하디스크 직경과 위치의 거동이 노즐압력비와 초기 상대습도의 항으로 소개된다. 대기흡입식 풍동설비에 장착된 노즐의 출구에서 부족팽창된 습공기 제트를 얻기 위해 노즐의 압력비와 초기상대습도를 변화시켰다. 마하디스크의 직경은 동일한 압력비에서 상대습도가 증가함에 따라 증가하지만, 그 위치는 상류로 이동하는 것으로 나타났다. 또한 노즐의 작동압력비가 증가하는 경우의 마하디스크 직경과 발생위치가 감소하는 경우보다 더 크다.

  • PDF

신조 운항실습선의 봄철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship)

  • 신동걸;이진욱;이형기;박윤철;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

멸균물품의 유효기간에 관한 연구: 포장재와 보관환경을 중심으로 (Validity Periods of Sterilization Products: Focus on Packing Materials and Storage Environments)

  • 박현희;이광옥
    • 근관절건강학회지
    • /
    • 제30권3호
    • /
    • pp.263-272
    • /
    • 2023
  • Purpose: The aim of this study was to provide a scientific basis for shelf life and re-establish the shelf life in a hospital environment by investigating the validity periods of various packaging materials. Methods: We selected six departments to store sterilized items, prepared 482 sterilized items, and stored them for 12 months. Each sample was tested using a microbiological culture in the laboratory every two weeks. When the result was positive, the sample was considered contaminated. The temperature and relative humidity were measured using an automatic control system to investigate the storage environment during the study period. Results: Except for two samples, which were positive in the 22nd and 28th weeks, 480 samples were negative. The temperature and relative humidity of the sample storage area were measured every week. The annual average temperature was 23.6±1.6℃, and the mean relative humidity was 35.1±15.2%. The cabinets used in this study were the two-open and four-closed types. Conclusion: This study confirmed the validity of the expiration date in a hospital environment. Based on the results, the nonwoven fabric remained sterile for more than nine months. No case of contamination of the paper-plastic pouch packaging was observed, owing to the microbial culture for two months.

실외조명 LED용 SMPS의 가속수명시험법 제안 (Suggested Accelerated Life Test Method of SMPS for Outdoor Lighting LED)

  • 임성용;형재필;임홍우;오근태
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.8-19
    • /
    • 2018
  • Purpose: This study has developed the accelerated lifetime test method for smps for outdoor lighting LED through two factors of temperature and humidity. Methods: Acceleration condition was confirmed for each stress and model, and acceleration life test model was estimated according to acceleration condition. Results: As a result of confirming the accelerated life test model, in the case of humidity, acceleration was established only in the foreign products. Therefore, it is confirmed that the acceleration condition is insufficient. However, the estimated parameters for temperature are relatively constant. It is therefore suitable for power supply acceleration tests for outdoor lighting LEDs. Conclusion: The SMPS acceleration test for outdoor lighting LED can improve the availability of the product by developing an accelerated life test method that guarantees the reliability of the product.

의약품 유통 관리용으로 사용되는 UHF 대역 RFID Tag의 가속수명시험법 개발 (Development of Accelerated Life Test Method for UHF RFID Tags for Medicine Supply Management)

  • 양일영;유상우;박정원;조원서
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권2호
    • /
    • pp.93-96
    • /
    • 2014
  • RFID (Radio Frequency IDentification) system is recognition technology which can maintain various object's information. Reliability of RFID tags is the most important factor in RFID system. In this paper, we proposed ALT (Accelerated Life Test) method for UHF RFID tags. Temperature and humidity were adopted as stress factors and the accelerated life tests were conducted in three different conditions. We performed failure analysis for identifying failure mechanism and statistical analysis of test data. In the statistical analysis, we employed Inverse Power law for relationship between tag's life and stress. Through the statistical analysis, we proposed acceleration factor for several levels of temperature-humidity. The reliability qualification test plans were also designed for the tag's target reliability.

냉동공조용 관군에서의 서리발생 및 제상 메커니즘에 관한 연구 (Study on frost Generation and Defrosting Mechanism on Evaporating Tubes for Refrigerator and Air condition industries)

  • 지재훈;김창복;문성배;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.234-235
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is 15$^{circ}C$, 20$^{circ}C$, 25$^{circ}C$ , supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept -15$^{circ}C$ because, generally cooling temperature range is constantly -15$^{circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost thickness in each condition and examine these data

  • PDF

와이어 전극과 평행판에서 발생되는 이온풍 특성 연구 (A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly)

  • 안영철;황필재;이재근
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

냉동공조용 증발기에서 서리의 발생 및 제상 메커니즘에 관한 연구 (A study on frost generation and difrosting mechanism on evaporating tubes for Air-conditioning system)

  • 지재훈;김창복;김명환;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.166-171
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is kept constantly $20^{\circ}C$, supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept $-15^{\circ}C$ because, generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost quantity in each condition and examine these data

  • PDF