• Title/Summary/Keyword: humidity supply

Search Result 172, Processing Time 0.026 seconds

Flower water supply assistant by sensor and Labview (Labview와 센서를 활용한 화초 물 공급 도우미)

  • Park, Sang-Gug
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.849-851
    • /
    • 2010
  • This paper applicate to the large flowers management house, personal office or home, which breed flowers for the profit or hobby. We suggest flower water supply assistant, which supply water anytime to prevent die from water shortage. Our system applicate to the flowerpot less than two at first. We measure humidity by use humidity sensor and control water supply valve automatically. The water supply valve will be opened when the humidity drop to the less than critical values.

  • PDF

Cooling Cycle for Energy Saving (에너지 절약용 냉방사이클)

  • Lee, Hung Joo;Kim, Yong Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger (핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰)

  • 최권삼
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier (신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가)

  • Hwang, Kwang-Il;Doe, Geun-Young;Cho, Hyo-Jae;Woo, Sang-Woo;Shin, Dong-Keol;Lim, Seong-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

A Study on Moisture Transport of Artificial Lightweight Concrete (인공경량골재 콘크리트의 수분이동 특성에 관한 연구)

  • Lee, Chang Soo;Choi, Sang Hyun;Park, Jong Hyok;Kim, Young Ook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.373-384
    • /
    • 2009
  • For the first step on the quantitative evaluation of shrinkage reduction and differential shrinkage analysis of lightweight aggregate concrete, this study sets the moisture transport model of concrete by pre-absorbed water of porous lightweight aggregates and measured effective moisture diffusion coefficient, moisture capacity, degree of humidity supply and degree of humidity consumption by water binder ratio and aggregate type. The effective moisture diffusion coefficient in steady state caused by humidity difference between inside and outside of concrete had low value as low water-binder ratio. And in case of same water-binder ratio, effective moisture diffusion of mixtures used normal aggregates were lower than those used lightweight aggregates. To determine moisture store capability of concrete - moisture capacity, moisture contents were measured in 9 humidity conditions. As a result moisture contents of mixtures used lightweight aggregates was higher than mixtures used normal aggregates in all humidity conditions. This study measured lightweight aggregates' degree of humidity supply that applicable to normal atmospheric environment (above RH 50%) and made it quantitatively. Also amount of moisture release was set as a exponential function that represents a clear trend proportion to time and inverse proportion to humidity of the surroundings. As the result of measurement about degree of moisture consumption inside concrete following the internal consumption caused by cement hydration self-drying, it was showed that rapid decrease of humidity, around 10%, at early ages (7~10 days) when water-binder ratio is 0.3 and slow decrease around 5% and 1% when water-binder ratio is 0.4 and 0.5.

An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger (핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구)

  • Park, S.K.;Yoon, S.H.;Kim, K.K.;Kim, M.H.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

The Study on Cooling Load Forecast of an Unit Building using Neural Networks

  • Shin, Kwan-Woo;Lee, Youn-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.170-177
    • /
    • 2003
  • The electric power load during the summer peak time is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. The method of forecasting the cooling load using neural network is also suggested. The daily cooling load is mainly dependent on actual temperature and humidity of the day. The simulation is started with forecasting the temperature and humidity of the following day from the past data. The cooling load is then simulated by using the forecasted temperature and humidity data obtained from the simulation. It was observed that the forecasted data were closely approached to the actual data.

Optimization of Air Supply for Increased Polymer Electrolyte Fuel Cell System Efficiency (고분자 전해질 연료전지 시스템의 효율향상을 위한 공기공급 최적화)

  • Chu, Keon-Yup;Jo, Ki-Chun;SunWoo, Myoung-Ho;Choi, Seo-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.44-51
    • /
    • 2011
  • Polymer Electrolyte Fuel Cells (PEFCs) operate in wide-range changes in temperature, humidity, and electric current for automotive applications. In order to operate automotive PEFC efficiently, optimal air supply is required to adjust to these changes. This paper presents an air-supply optimization process that consists of experiments, modeling of the PEFC system, and optimization. The objective is to establish an air supply suitable for the required power for PEFC system and optimized with a Lagrange multiplier. Our simplified PEFC system model is used as a constraint for optimization problem. The result of this paper presents that efficient operation of PEFC system can be achieved by air-supply optimization.

Gas Detecting Characteristics Using Catalytic Combustion Type Gas Sensor (접촉연소식 가스 센서를 이용한 감도특성)

  • Yoon, Hun-Ju;Ko, Keel-Young;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.773-777
    • /
    • 2002
  • In this study, we analyzed the LPG and LNG sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 0~85 percent at a temperature of $20[{\mu}m]$ and humidity of 45 percent at a temperature of $-10{\sim}40[^{\circ}C]$ the gas detecter sensors are to be subjected to operation for 210 days in an area that has been detemined to be equivalent to a typical residential atmosphere with an air velocity of 50 [cm/sec]. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a separate source of supply direct applied voltage 2.1[V], 2.2[V], 2.3[V]. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the LPG characteristic graph and methane characteristics graph by a relative humidity of 0 ~ 85 [%] at a temperature range of $-10{\sim}40[^{\circ}C]$ show a similar linear pattern on the whore.

  • PDF

Implementation of Fuzzy Logic Control for Air Conditioning Systems

  • Mongkolwongrojn, M.;Sarawit, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1264-1267
    • /
    • 2005
  • Fuzzy logic control has been widely applied for handling the system which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters, several fuzzy logic controllers have been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control both in door temperature and humidity in the air conditioning systems. The manipulating variables are speed of compressor, heater and supply air flow rate. The microcomputer was used to interface with in system. The experimental results show the superior of multivaiable fuzzy logic control to keep room temperature and humidity in air conditioning system for the best comfortable.

  • PDF