• Title/Summary/Keyword: humerus fracture

Search Result 151, Processing Time 0.043 seconds

The Outcomes of Proximal Humerus Fractures with Medial Metaphyseal Disruption Treated with Fibular Allograft Augmentation and Locking Plate

  • Kim, Doo Sup;Yoon, Yeo Seung;Kang, Sang Kyu;Jin, Han Bin;Lee, Dong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.90-94
    • /
    • 2017
  • Background: Proximal humerus fracture is considered to be the third most common fracture for patients aged 65 years or older. Conservative treatment has been known to treat most of humerus fracture. However, fractures with severe displacement or dislocation may require surgical treatment. Intramedullary fibular allograft with a locking plate is frequently used in patients accompanying medial metaphyseal disruption. In this study, author intends to evaluate clinical and imaging results based on patients who underwent surgical treatment using fibular allograft with a locking plate. Methods: This study is conducted prospectively at Wonju Severance Christian Hospital, targeting patients who previously underwent surgical treatment using open reduction and intramedullary fibular allograft with a locking plate between 2011 and 2015. A total of 26 patients were evaluated on the following: postoperational clinical assessment measuring Constant score, American Shoulder and Elbow Society (ASES) score, and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Postoperational imaging assessments are evaluated via measuring the neck-shaft angle. The study subject were Neer classification type 3, 4 proximal humerus fracture cases with disrupted medial hinge and having cortical comminution in the region of the surgical neck. Results: The average period of progression was 22.5 months, and the average age of patients was 72.6 years. At the final follow-up, the average Constant, average ASES, and average DASH scores were 80.1, 78.5, and 20.6 respectively. The average neck-shaft angle was $127.5^{\circ}$. Conclusions: In conclusion, fibular allograft augmentation with a locking plate showed satisfying results in both clinical and imaging studies.

Hemiarthroplasty for Distal Humerus Fracture: A Systematic Review and Meta-analysis for Functional Outcome

  • Kwak, Jae-Man;Kholinne, Erica;Sun, Yucheng;Lee, Gwan Bum;Koh, Kyoung Hwan;Chun, Jae-Myeung;Jeon, In-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.120-126
    • /
    • 2018
  • Background: Treatment of distal humerus fractures in osteoporotic elderly patients is often challenging. For non-reconstructible fractures with open reduction and internal fixation, total elbow arthroplasty (TEA) is an acceptable alternative. However, the relatively high complication rates and lifelong activity restrictions make TEA less ideal for elderly or low-demand patients. Efforts to identify or develop alternate procedures that benefit relatively young, high-demand patients have resulted in increased interest in hemiarthroplasty. This systematic review reports the clinical outcomes of hemiarthroplasty for distal humeral fractures. Methods: We systematically reviewed the databases of PubMed, Ovid MEDLINE, and Cochrane Library. All English-language studies published before June 2017 were considered for possible inclusion. Search terms included 'distal humerus fracture' and 'hemiarthroplasty'. Studies reporting outcomes (and a minimum of 1 year clinical follow-up) in human subjects after hemiarthroplasty (Latitude system) for distal humeral fractures were assessed for inclusion. Patient demographics, clinical and radiographic outcomes, and complications were recorded, and homogenous outcome measures were analyzed. Results: Nine studies with a total of 115 patients met the inclusion criteria. Among the included studies, the weighted mean follow-up time was 35.4 months. Furthermore, the weighted mean of the postoperative range of motion ($107.6^{\circ}$ flexion-extension, $157.5^{\circ}$ for pronation-supination) and functional outcomes (Mayo elbow performance scores: 85.8, Disabilities of the Arm, Shoulder and Hand score: 19.6) were within the acceptable range. Conclusions: Our study indicates that hemiarthroplasty is a viable option for comminuted distal humerus fracture. Satisfactory functional outcomes were observed in most patients.

Hemiarthroplasty for Fractures or Fracture-Dislocations of the Proximal Humerus (상완골 근위부 골절 또는 골절 및 탈구에서의 상완골 두 치환술)

  • Kim Young Kyu;Eom Gi Serk
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • Purpose : To evaluate functional results and study factors influencing results after humeral hemiarthroplasty for comminuted fractures of the proximal humerus. Materials and Methods: We reviewed 12 patients with average follow-up period of 23 months(12 to 42). The proximal humeral fractures consisted of one anatomical neck fracture, five three-part and six four-part fractures or fracture-dislocations. Constant score and Compito et al' evaluation system were used for clinical assessment. Statistical analysis was done with the Wilcoxon test. Results: Six cases of anatomical neck, three-part fractures or fracture-dislocations showed 61 points on the average Constant score and three unsatisfactory results on the Compito et al' evaluation; Six of four-part fractures or fracture-dislocations showed 51 points and three unsatisfactory results. There were 59(two unsatisfactory) for five non-associated dislocation and 53(four unsatistactory) for seven associated dislocation; 66(one unsatisfactory) for three under 60 years and 41(five unsatisfactory) for nine over 60 years; 67(two unsatisfactory) for seven tuberosity union and 41(four unsatisfactory) for five tuberosity non-union or resorption; 58(four unsatisfactory) for ten early operation within two weeks and 43(all unsatisfactory) for two delayed operation; and 18(unsatisfactory) for one case of a accompanied rotator cuff tear. Conclusion: We concluded that tuberosity union was important factor influencing the results. Also, we thought that age, timing of operation and accompanied rotator cuff tear could be influenced to results.

  • PDF

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.

Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report - (제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 -)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Yang, Hui Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • We report a case of recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I. A twenty-year-old male patient with known neurofibromatosis type I presented with right shoulder dislocation and proximal humerus fracture following a minor trauma. His injured arm also had large plexiform neurofibromas on the elbow, and the dislocation of the shoulder joint was proven to be recurrent. Bony deformation of the humerus and scapula were revealed on X-ray and computed tomography, as well as multiple neurofibromatic changes of the deltoid and periscapular muscles were noted on magnetic resonance imaging. Open reduction and capsular reconstruction were performed and humeral fracture was stabilized with a reconstruction plate. Satisfactory union and functional result were achieved and the dislocation did not recur until the 7-month followup after the procedure. Recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I are rare complications. However, it should still be considered in the orthopaedic evaluation process of the diseases.

Percutaneous K-wire Fixation of Supracondylar Fracture of Humerus in Children (소아 상완골 과상부 골절의 경피적 K-강선 고정술)

  • Shin, Duk-Seop;Ahn, Jong-Chul;Kim, Se-Dong;Lee, Dong-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.400-408
    • /
    • 1993
  • During the period from March 1990 to November 1993, 22 children with diplaced supracondylar fracture of humerus were treated by closed reduction and percutaneous K-wire fixation at department of Orthopaedic surgery in Yeungnam University. All fracture were treated with closed reduction under the general anesthesia and percutaneous pinning. After the fracture was internally fixed, intraoperative anteroposterior reontgenograms of each distal humerus were compared. Only anatomical reduction ensured good result, because the main cause of late cubitus varus was medial tilting of distal fragment. We could follow up 10 patients more than one year. By Flynn's criteria, satisfactory result were obtained in 9 of the 10. Unsatisfactory one had a limitation in flexion of elbow joint, but had no problem in cosmetic feature. In short term follow up of 7 patients, 5 patients had a satisfactory result, too. There were no neurovascular complication and hospitalization was shortened to 11.4 days. Closed reduction and percutaneous pinning provided stabillity, vascular safety, simplified management, reduced hospital stay. This is safe and reliable technique for obtaining and maintaining an excellent reduction.

  • PDF

Results of Closed Reduction and Percutaneous Fixation of the Supracondylar Fractures of the Humerus in Adults (성인의 상완골 과상부 골절의 도수 정복 후 경피적 고정 방식의 치료 결과)

  • Park, Jin-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.5 no.2
    • /
    • pp.102-109
    • /
    • 2002
  • Purpose: To evaluate the results of the treatment of the supracondylar fractures of the humerus according to the fixation methods in adults Materials and Methods: Seven patients, aged 55 to 52 years (average,69 years), were reviewed after a mean follow-up of 37 months (range, 11-65 months). According to AO classification all fractures were classified as type A2 (simple transverse supracondylar fracture). Six patients underwent closed reduction and one patient, open reduction after failure of closed reduction. Percutaneous fixation with cannulated screws was performed to the 4 patients, per- cuta)leous fixation with Kirschner wires in 3 patients. All except one patients have associated medical problems. The results were assessed based on the Mayo Elbow Performance Score. Results: All the patients with cannulated screw fixation had stable bony union with excellent ranges of motion (mean: 5-125 degrees). All the three patients who received percuatnaous smooth K-wire fixation had nonunion with poor results, one of them had changed into cannulated screw. and then had good result. Conclusion: Although simple supracondylar fracture is similar to the pediatric fracture in nature, it should be firmly fixed with the method such as threaded cannualted screw rather than the simple fixation with K-wires.

Pulmonary Embolism after Screw Fixation for a Greater Tubercle Fracture of Humerus

  • Kang, Suk;Chung, Phil Hyun;Kim, Jong Pil;Kim, Young Sung;Lee, Ho Min;Jang, Han Gil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.201-204
    • /
    • 2014
  • Pulmonary embolism is a serious complication, which is well known in patients undergoing total hip or total knee arthroplasty or lower extremity fracture surgery. But, there are few literatures concerning pulmonary embolism after upper extremity surgery. Pulmonary embolism after minor upper extremity fracture surgery is extremely rare. We report a case of 66-year-old female patient that developed pulmonary embolism after percutaneous cannulated screw fixation for a greater tubercle fracture of the proximal humerus with literature review.

Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture (잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료)

  • Ha, Sung-Sik;Kim, Jae-Young;Hong, Ki-Do;Sim, Jae-Chun;Kang, Jung-Ho;Park, Kwang-Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2008
  • Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP). Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer's evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method. Results: The mean time for bone union was 11.9 weeks. Using the Neer's functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient). Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.

Operative Treatment with Intramedullary Fibular Strut Allograft for Osteoporotic Proximal Humerus Fracture

  • Chun, Yong-Min;Lee, Wonyong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.95-99
    • /
    • 2017
  • Background: The purpose of this study was to investigate the clinical and radiological outcomes of locking plate fixation with fibular strut allograft to manage unstable osteoporotic proximal humerus fractures. Methods: We retrospectively reviewed 15 patients who underwent open reduction and locking plate fixation with fibular strut allograft for osteoporotic proximal humerus fracture between July 2011 and June 2015. For functional evaluation, we evaluated visual analogue scale (VAS) pain score, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) shoulder score, and active range of motion. For radiological evaluation, shoulder true anteroposterior (AP) and AP in $20^{\circ}$ external rotation, as well as the axillary view were taken at two weeks, six weeks, three months, six months, and one year. And the neck-shaft angle was measured on the AP view in $20^{\circ}$ external rotation view. Results: At the one-year follow-up, mean VAS pain score and all shoulder scores, including ASES score and UCLA shoulder score, exhibited satisfactory clinical outcomes. All patients obtained bone union between three and six months post-procedure. Moreover, the mean immediate postoperative neck-shaft angle was $138^{\circ}{\pm}4^{\circ}$, and at one-year follow-up, the neck shaft angle was $137^{\circ}{\pm}5^{\circ}$. There was no significant difference between the preoperative and postoperative values (p=0.105). Conclusions: For the unstable two-part and three-part osteoporotic proximal humerus fractures with medial calcar comminution, the use of fibular strut allograft with locking plate fixation was effective in maintaining the initial status of reduction and exhibiting the satisfactory functional and radiological outcomes.