• 제목/요약/키워드: hume concrete pipe

검색결과 9건 처리시간 0.021초

주택단지 오수용 콘크리트 흄관의 부식속도 측정 사례 (A Case Study on Corrosion Rates of Concrete Sewer Pipes in Housing Sites)

  • 김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.550-553
    • /
    • 2006
  • This study measured corrosion rates for checking and analysis of Hume pipes in the housing sites. According to the result, Concrete pipe is deteriorating for twenty years by hydrogen sulfide(H2S). Investigation method applied phenolphthalein method(depth of neutrality). Phenolphthalein method measured average depth from concrete surface to coloring point by red after spraying phenolphthalein solution. A result of investigation, Life span of Hume pipe in the housing site is investigated of twenty years.

  • PDF

흄관매설 자동화 장비의 성능평가에 관한 연구 (A Study on the Performance Evaluation of a Tele-operated Hume Concrete Pipe Laying Machine)

  • 유연택;박상준;변웅호;김영석;이준복
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.634-637
    • /
    • 2003
  • 건설 자동화 장비 개발의 성공여부를 판단하고 이를 실용화하기 위해서는 개발 장비의 성능평가 및 분석을 통해 재래식 방식과 비교하여 자동화 방식을 도입함으로써 얻을 수 있는 기대효과가 제시되어야만 한다. 본 연구에서는 최근 국내에서 개발된 흄관매설 자동화 장비의 성능분석을 위한 평가모델 및 방법론을 제시하고 수차례의 현장실험(field trials)을 통해 수집된 실험 데이터를 바탕으로 재래식 흄관매설 방식과 자동화 방식의 성능을 종합적으로 비교${\cdot}$분석함으로써 재래식 방식에 비해 자동화 방식의 도입을 통해 얻을 수 있는 정성적${\cdot}$정량적 기대효과를 제시하였다. 흄관매설 자동화 장비의 성능분석을 위해 본 연구에서 ,제시된 성능분석 프로세스 및 평가모델은 향후 건설자동화 관련 기술개발 시 자동화 장비의 성능분석 및 평가모델을 개발함에 있어 기본적 틀(template)을 제공할 수 있을 것으로 기대된다.

  • PDF

흄관매설 자동화 장비의 성능분석을 위한 평가모델의 개발 (Development of the Evaluation Model for Performance Analysis of a Tele-operated Hume Concrete Pipe Laying Machine)

  • 유연택;박상준;이정호;정명훈;김영석
    • 한국건설관리학회논문집
    • /
    • 제5권1호
    • /
    • pp.157-167
    • /
    • 2004
  • 건설 자동화 장비 개발의 성공여부를 판단하고 이를 실용화하기 위해서는 개발 장비의 성능평가 및 분석을 통해 재래식방식과 비교하여 자동화 방식을 도입함으로써 얻을 수 있는 기대효과에 대한 검증이 이루어져야 한다. 본 연구에서는 최근 국내에서 개발된 흄관매설 자동화 장비의 성능분석을 위한 평가모델 및 방법론을 구축하고 수차례의 현장실험(field trials)을 통해 수집된 실험 데이터를 바탕으로 재래식 흄관매설 방식과 자동화 방식의 성능을 종합적으로 비교$\cdot$분석함으로써 재래식 방식에 비해 자동화 방식의 도입을 통해 얻을 수 있는 정성적 $\cdot$정량적 기대효과를 제시하였다. 흄관매설 자동화 장비의 성능분석을 위해 본 연구에서 제시한 성능평가 모델 및 방법론은 향후 건설자동화 관련 기술개발 시 자동화 장비의 성능평가 및 분석 모델을 개발함에 있어 기본적 틀(framework)을 제공할 수 있을 것으로 기대된다.

PE 피복형 파형강관의 플랜지 이음부 설계에 관한 연구 (A Study on Flange Coupling Design of Polyethylene Corrugated Steel Pipe)

  • 김태규;이호영;양상민
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.403-408
    • /
    • 2007
  • The concrete pipe(Hume, PC) and polyethylene(PE) pipe are usually used for dram pipe in local market. Hume pipe, however, is heavy and needs the high cost of construction and PC pipe has a disadvantage to easily occur the deformation by the outside pressure even though it is light and constructible. The corrugated steel pipe coated with polyethylene is used increasedly because it is durable, constructible and economical. However, it is not used for sewage or waste water because it is hard to guarantee the watertight property on the coupling part. In this study, we studied on the flange coupling and the method of its construction to guarantee the watertight property and easy to use. If the developed flange coupling and method are used on a construction field, the economical property, constructible property and structural safety can be guaranteed.

샌드위치형 GFRP 아치의 구조적 거동 및 현장 적용성 (Structural Behavior of Sandwich Type GFRP Arch and Field Applicability)

  • 황대원;김광우;김용성;연규석
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.85-93
    • /
    • 2018
  • This study investigated the structural behavior and field applicability of sandwich type GFRP arches with polymer mortar in core. As a result, in case of crack loading and failure loading, total strains at crown were the highest; the fracture strain at crown was 0.01690, which is 4.2 times greater than the fracture strain (0.004) of cement concrete. The 3 % deflection load was 17.42 kN, the flexural strength was $163.98{\times}10^{-3}GPa$, and the flexural elastic modulus was 11.884 GPa. From load-deflection relationship up to 3.5 % deflection, 3D analysis results and experimental values were observed to be almost identical. It was considered reasonable to set a deflection rate limit to be 3 % for structural safety purpose. The standard external flexural strength of semicircular arch used in this study was approximately 2.64 times higher than that of hume pipe (2 type standard) and tripled composite pipe. The external pressure strength at fracture was approximately 1.57 times higher than that of hume pipe. It was confirmed that the implementing semicircular arch had mechanically more advantage than the circular pipe. Optimum member thickness was 8~53 mm according to arch radius of 450~1,800 mm and cover depth of 2~10 m. It was found that the larger strength could be obtained even if the thickness of member was smaller than that of concrete structure. In field application study, figures and equations were derived for obtaining applicable cover depth and optimum member thickness according to loading conditions. These would be useful data for design and manufacture of sandwich type semicircular arch.

매설조건에 따른 연성관의 변형특성 (Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions)

  • 이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제15권10호
    • /
    • pp.53-62
    • /
    • 2014
  • 국내의 경우 하수관으로 많이 사용되어 온 관종은 콘크리트 흄관으로 대표되는 강성관이 주를 이루고 있으나, 시간 경과에 따른 관 부식 및 수밀성 부족 등의 이유로 사용이 급격히 감소하고 있다. 반면에 연성관은 부식에 강할 뿐만 아니라 자재의 무게가 경량이어서 시공성이 우수한 장점이 있어 사용이 증가하고 있는 실정이다. 그러나 연성관에 대한 시장의 신뢰성 부족과 미흡한 다짐관리로 인한 국부적인 파손사례가 발생하고 있어 이에 대한 원인분석 및 관리방안이 필요한 실정이다. 이에 본 연구에서는 시공순서, 관의 강성, 관 하부 콘크리트 기초의 강도, 관 하부 모래기초의 다짐도, 관 주변 모래의 다짐도 및 관 상단 되메움재의 다짐도 등을 변화시켜 가며 각각의 조건에 따른 관의 변형특성을 수치해석을 통하여 평가하였다. 평가결과 각 인자에 대한 영향을 확인할 수 있었으며 특히 연성관의 경우 관 주변 모래의 품질관리가 중요한 것으로 나타났다.

철근콘크리트흄관 라이닝용 니켈계 방균제의 기초적 특성 연구 (A Study on the Base Properties of Nickel Type-Antifungal Agent for Reinforced Concrete Hume Pipe Lining)

  • 조영국
    • 한국건축시공학회지
    • /
    • 제10권4호
    • /
    • pp.41-47
    • /
    • 2010
  • 본 연구는 철근콘크리트 흄관의 내구성을 개선시킬 목적으로 흄관 내부에 폴리머 시멘트 모르타르로 라이닝 처리한 부분에 황산니켈 6수화물을 혼입시켜, 하수용으로 사용되는 철근콘크리트 흄관의 열화에 크게 영향을 미치는 황산화 세균의 번식을 억제하기 위하여 실시하였다. 본 연구에서는 황산화세균의 증식을 억제시키기 위하여 황산니켈 6수화물의 농도에 따른 성능을 평가하였으며, 방균제에 함유된 황산이온이 시멘트 모르타르의 팽창요인 되어 역학적성질에 영향을 미칠 수 있기 때문에 팽창성 시험과, 니켈의 중금속의 용출로 환경오염은 물론 흄관의 내구성에 영향을 미치기 때문에 용출시험도 실시하였다. 본 연구 결과, 니켈계 방균제가 시멘트 콘크리트의 부식균인 Thiobacillus novellus의 증식을 억제하기 위해서는 20mM 이상을 사용하여야 효과가 있는 것으로 평가되었으며, 방균제를 혼입한 시멘트 모르타르의 압축강도 및 휨강도는 방균제의 혼입여부에 따라 크게 영향을 받지 않았다. 또한 방균제 혼입에 따른 특별한 팽창현상은 발견되지 않았으며, 모든 종류의 시멘트 모르타르에서 니켈성분이 전혀 용출되지 않았다. 본 연구를 통하여 철근콘크리트 흄관의 내구성 개선을 위하여, 흄관 내부의 라이닝과 함께 방균제를 혼입한다면, 두가지 방식재료의 성능이 서로 보완효과를 일으킬 수 있을 것으로 판단되었다.

터널 방음시설의 방음재질 종류에 따른 소음과 주파수의 크기 고찰 (A Study on the Magnitude of the Noise and Frequency According to Materials for Soundproof Facilities of Tunnel)

  • 원연호;조영동;정재형
    • 화약ㆍ발파
    • /
    • 제25권2호
    • /
    • pp.23-33
    • /
    • 2007
  • 터널발파작업에 따른 발생소음의 크기는 소음 계측기의 특성상 근거리의의 측정이 불가하며 방음재질의 종류에 따라 소음저감 효과는 매우 다양한 차이를 나타낸다. 본 연구에서는 터널발파작업에 따라 설치되는 방음시설의 방음재질과 종류에 따른 소음저감 효과와 근거리에서의 소음예측방법을 조사하였다. 방음재질과 종류에 의한 소음과 주파수의 크기를 비교 분석하기 위하여 콘크리트 흄관 내에서 화공품의 일종인 폭죽으로 소음을 발생시키고 약 20여 종류의 방음재질을 설치하여 근거리에서 소음과 주파수의 크기를 측정 고찰하였다.

SLD동조 광원과 에탈론 필터를 이용한 FBG 센서 신호처리 시스템 (FBG Sensor Signal Processing System using SLD Tunable Light Source and Etalon Filter)

  • 정철;이호준;김기수
    • 대한전자공학회논문지SD
    • /
    • 제41권3호
    • /
    • pp.39-44
    • /
    • 2004
  • 광섬유 브래그 격자 센서는 광섬유의 코어의 굴절률 변조에 의해서 제작되며, 이 센서는 외부의 스트레인에 따라 브래그 파장이 변화하게 된다. 본 논문에서는 광섬유 브래그 격자 센서를 파장 영역에서 신호처리 할 수 있는 방법에 대하여 연구하였다. SLD와 F-P 필터로 구성된 sweep 반도체 광원과 F P 필터내의 PZT의 히스테리시스 특성을 보상하기 위한 에탈론 필터와 장기 계측을 위해 절대 파장 기준으로 온도 안정된 광섬유 브래그 격자를 사용하였다. 콘크리트 흄관에서 FBG 센서의 스트레인 응답 특성을 전기저항 센서와 비교하였다. 그리고 광섬유 격자 센서를 이용하여 장거리 변위의 측정 가능성을 확인하였다.