• Title/Summary/Keyword: human pressure

Search Result 1,117, Processing Time 0.026 seconds

A Screening Test of Extensibility and the Prediction of Clothing Pressure for Commercial Compression T-shirts (시중 컴프레션 티셔츠의 신장 특성에 대한 스크리닝 테스트와 의복압 예측)

  • Kim, Nam Yim;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1010-1021
    • /
    • 2017
  • Adjustment of clothing pressure for compression wear is critical to the physiological and psychological satisfaction of the wearer; however, there are limited studies on the practical relationship among extensibility of materials, pattern reduction of compression wear and resultant clothing pressure. This study provides consumers and designers with information on clothing pressure using a screening extensibility test suggested by Ziegert and Keil (1988) even for the final products. As the first step, ten commercial products were collected and their size, extensibility and corresponding clothing pressure were analyzed. It was found that clothing pressure around the waist level could be predicted well from the information of Ziegert and Keil's (1988) % extensibility of the material (Z stretch %) and the actual application of Z stretch amount to the pattern reduction rate (applied % of Z stretch), with an $r^2$ of around 0.80, especially at the waist level. However, it was not simple for the case of clothing pressure around the back of the chest level due to the various design variation and the complexity of the anatomical structure around the trapezius.

Changes in The Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation (뇌압 펄스에 의한 션트밸브의 압력-유량제어 특성의 변화)

  • 홍이송;이종선;장종윤
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.391-395
    • /
    • 2002
  • Shunt valves used to treat patient with hydrocephalus were numerically simulated to investigate influence of pressure pulsation on their flow control characteristics. We modeled flow orifice through the shunt valve and imposed pulsating pressure and valve diaphragm movement to compute flow through the valve. The results of our study indicated that flow rates increased more than 40% by introducing pressure pulsation and diaphragm movement on the shunt valve. Our results demonstrate the pressure-flow control characteristics of shunt valves implanted above human brain may be quite different from those obtained by syringe pump test just after manufacture that induces uniform pressure.

Effects of the Body Shaping Foundation on Blood Flow and Wearer Comfort for Middle-aged Women (시판 체형보정용 파운데이션이 중년여성의 혈류 및 착용 쾌적감에 미치는 영향)

  • Kim, Nam Yim;Park, Gin Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.3
    • /
    • pp.495-509
    • /
    • 2021
  • The study investigated the effects of five commercial body shaping foundation items on clothing pressure, blood flow, body shaping effectiveness, and wearer satisfaction for middle-aged women. The study measured clothing pressure at each of the 10 designated measurement points for twelve subjects wearing the foundations. Blood flow changes were recorded and body shaping effectiveness was analyzed by comparing differences in girth when wearing and not wearing the foundations. The subjects rated wearer comfort along a 7-point Likert scale. The results were that clothing pressure was present at all measurement points, and all foundations placed the least pressure on the anterior underbust girth. In addition, clothing pressure was high in the order of the lateral, posterior, and anterior areas. As clothing pressure increased, blood flow and velocity decreased and overall wearer satisfaction was assessed to be less comfortable. Body shaping effectiveness was evident across all the items, as all decreased girth measurements significantly. In conclusion, the appropriate level of clothing pressure provided by experimental foundations which is positive for blood flow and has an excellent body shaping effect was found to be between 0.53 and 1.77 kPa.

Mock Circulatory Robot with Artificial Aorta for Reproduction of Blood Pressure Waveform (혈압 파형 재현을 위한 인공 대동맥 기반 모의 순환계 로봇)

  • Jae-Hak Jeong;Yong-Hwa Park
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.2
    • /
    • pp.221-228
    • /
    • 2024
  • As the importance of cardiovascular health is highlighted, research on its correlation with blood pressure, the most important indicator, is being actively conducted. Therefore, extensive clinical data is essential, but the measurement of the central arterial blood pressure waveform must be performed invasively within the artery, so the quantity and quality are limited. This study suggested a mock circulatory robot and artificial aorta to reproduce the blood pressure waveform generated by the overlap of forward and reflected waves. The artificial aorta was fabricated with biomimetic silicone to mimic the physiological structure and vascular stiffness of the human. A pressurizing chamber was implemented to prevent distortion of the blood pressure waveform due to the strain-softening of biomimetic silicone. The reproduced central arterial blood pressure waveforms have similar magnitude, shape, and propagation characteristics to humans. In addition, changes in blood pressure waveform due to aging were also reproduced by replacing an artificial aorta with various stiffness. It can be expanded to construct a biosignal database and health sensor testing platform, a core technology for cardiovascular health-related research.

A Review of Recent Acupuncture Treatment for Hypertension - PubMed and Domestic Studies (고혈압 침치료에 관한 최근 연구 동향 고찰 - Pubmed와 국내 논문 중심으로 -)

  • Kim, Seung-yeon;Won, Jae-ho;Lee, In
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.1
    • /
    • pp.29-43
    • /
    • 2020
  • Objectives: The purpose of this study was to summarize current research trends and results regarding acupuncture treatment for hypertension. Methods: Articles published from 2009 to 2019 were searched on domestic databases (OASIS, NDSL, RISS) and PubMed using the keywords 'Hypertension', 'Hypertensive', 'Acupuncture', 'EA' (electroacupuncture), 'Autonomic nervous system', 'ANS', 'CVD' (cardiovascular disease), '고혈압', '침', '전침', and '자율신경계'. The studies were analyzed according to the year, type of study (domestic or foreign articles, nationality of the first author), acupuncture type for human and animal studies, BP (blood pressure) measurement, and acupuncture intervention. Results: In total, 21 articles were selected. There were 8 randomized controlled trials (RCTs), 3 non-randomized controlled trials (nRCTs), 2 before-after studies, 1 case series, and 7 animal studies. Manual acupuncture (11 articles) was most frequently used, and ST36 (足三里) was most frequently used in human studies. In 18 of 21 articles, acupuncture was reported as effective in lowering systolic blood pressure (SBP) or diastolic blood pressure (DBP) in hypertensive patients. Conclusions: Acupuncture treatment for hypertension is deemed useful. Further studies are necessary for application of acupuncture therapy in clinical practice.

Dietary Risk Factors for Hypertension among Korean Adult Men

  • Park, Jin-Young;Shim, Jae-Eun;Paik, Hee-Young
    • Journal of Community Nutrition
    • /
    • v.8 no.4
    • /
    • pp.193-199
    • /
    • 2006
  • There have been many studies indicating increased salt intake is related to elevated blood pressure (BP). Hypertension and pre-hypertension are prevalent in Korea. A national survey showed that the Korean average daily salt consumption was 12.5g, which is more than twice the current recommendation in the UK or USA. This study was performed to understand which aspects of the Korean diet contributed to high salt intake and elevated BP in Korea. The subjects consisted of 1,110 Korean adult men aged 30 to 49 years who were selected from the data of 2001 Korean National Health and Nutrition Survey, a nationwide cross sectional survey. The relationship of BP with sodium and high sodium food intakes were analyzed. After categorizing subjects according to their BP, the socio-demographic information and food and nutrients intakes were analyzed. BP increased with a larger amounts of sodium intake and the trend was significant with diastolic BP. However, the trends of BP for sodium densities of the diet were not. People with hypertension significantly tended to be older, larger, and less educated than people with normal BP. And they consumed more foods from the fats, oils & sweets group and larger amounts of discretionary sodium than normal people. The current report advocates that public health intervention, which improves the awareness of the role of salt on elevated blood pressure for the public, should be implemented in Korea.

A Study on Design of Posture Transition Filter for 3D Human Posture Estimation and Refinement on Robotic Bed (침대 로봇의 3차원 자세 추정 및 개선을 위한 자세 천이 필터 설계 연구)

  • Lee, Jong-il;Han, Jong-Boo;Koo, Jae Wan;Choi, Jae-Won;Hahm, Jehun;Yang, Kyon-Mo;Sohn, Dong-Seop;Seo, Kap-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.3
    • /
    • pp.269-276
    • /
    • 2020
  • As we become an aging society, the number of elderly patients continues to increase. Pressure sores that can easily occur in patients with trauma cause serious socio-economic problems. In general, prevention of bedsores through predicting the patient's posture is being developed. Developed method usually use artificial intelligence techniques to estimate the patient's posture by measured pressure images in the mattress. In this method, it has a problem the reduction of estimation accuracy when posture of patient is changed. Therefore, it is necessary to use the filter of pressure images in the position transition of patient. In this paper, we propose an algorithm to predict the patient's posture, and an algorithm to reduce the ambiguity that can occur in the patient's posture transition section. By obtaining stable data through this algorithm, learning/prediction stability of the neural network can be expected, and prediction performance is improved accordingly. Through experiments, the effectiveness of the algorithm was verified.

Fit and Pressure Analysis of Cycling Short Sleeve Tops Using a 3D Virtual Garment System

  • Park, Hyunjeong;Do, Wolhee
    • Fashion & Textile Research Journal
    • /
    • v.23 no.2
    • /
    • pp.237-246
    • /
    • 2021
  • This study aims to analyze short sleeve cycling tops from three brands for a change in garment fit and pressure depending on the static and cycling postures. To this end, it used a 3D virtual garment system to virtualize the garments. Further, a cross-section of the 3D virtual garment data was obtained, and the space length was measured in the design-X program to prove the objectivity of the 3D virtual garment. The results indicated that three brands had a large space length at the front than the back because of the bent posture in cycling. Therefore, appropriate ease was required for the waist and abdomen. Although there were various cutting lines of the bodice panel by brand, the design of the cutting lines should consider the changes in the surface to reflect the bent posture in cycling. The results of this experiment confirmed that the wrinkles present in the 3D virtual garment were reflected in the cross-section and that the space length was small in the high-stress area, as shown in red. Therefore, it was proven the stress of the 3D virtual garment could be used for 3D virtual garment evaluation.

Smart Wrist Band Considering Wrist Skin Curvature Variation for Real-Time Hand Gesture Recognition (실시간 손 제스처 인식을 위하여 손목 피부 표면의 높낮이 변화를 고려한 스마트 손목 밴드)

  • Yun Kang;Joono Cheong
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.1
    • /
    • pp.18-28
    • /
    • 2023
  • This study introduces a smart wrist band system with pressure measurements using wrist skin curvature variation due to finger motion. It is easy to wear and take off without pre-adaptation or surgery to use. By analyzing the depth variation of wrist skin curvature during each finger motion, we elaborated the most suitable location of each Force Sensitive Resistor (FSR) to be attached in the wristband with anatomical consideration. A 3D depth camera was used to investigate distinctive wrist locations, responsible for the anatomically de-coupled thumb, index, and middle finger, where the variations of wrist skin curvature appear independently. Then sensors within the wristband were attached correspondingly to measure the pressure change of those points and eventually the finger motion. The smart wrist band was validated for its practicality through two demonstrative applications, i.e., one for a real-time control of prosthetic robot hands and the other for natural human-computer interfacing. And hopefully other futuristic human-related applications would be benefited from the proposed smart wrist band system.

Nature-Inspired high sensitivity tactile sensor technology (자연모사 고감도 촉각센서 기술)

  • Kim, Tae Wi;Lee, Eun Han;Kang, Daeshik
    • Vacuum Magazine
    • /
    • v.4 no.3
    • /
    • pp.6-11
    • /
    • 2017
  • The tactile sensor of the future robot is becoming a necessity as a sensory organ which can communicate with the person most directly. Recently, the Nature-inspired technology has provided a new direction for the development of these tactile sensors. Here, we review three different nature-inspired tactile sensory system; high sensitivity pressure sensor inspired by beetle wings, highly sensitive strain sensor inspired by the spider's sensory organs, Tactile sensor inspired by human fingertip. These nature-inspired tactile sensors are expected to provide a breakthrough that not only can sensitively measure the pressure, but also delicately recognize the softness and texture of the material just like human.