• Title/Summary/Keyword: human body part model

Search Result 79, Processing Time 0.025 seconds

Development of a hip model for impact testing of bedsore prevention cushions (욕창예방 방석의 충격시험용 둔부 모형 개발)

  • JUNG, SUNGBAE;YUK, SUNWOO;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.7-11
    • /
    • 2024
  • The bedsore prevention cushion serves to prevent the skin on the buttocks of a wheelchair user from being damaged through friction with the wheelchair seat. This is because it absorbs some of the weight applied to the wheelchair seat and allows the weight to be applied evenly to the entire contact surface. For the impact test, which is part of the performance testing of bedsore prevention cushions, a hip model that represents the sitting posture of a wheelchair user is required. In this study, a hip model was manufactured for impact testing of bedsore prevention cushions for wheelchairs. Performance tests for pressure bedsore prevention cushions for wheelchairs include KSP 0236, a Korean standard, and KS P ISO 16840-2, an ISO international standard. The hip model proposed in KS P ISO 16840-2 was more suitable for impact testing of bedsore prevention cushions for wheelchairs. However, the guidelines for making hip models proposed by international standards need to be modified to reflect the advancement of model making technology and use easier methods. We propose a new hip model production method that produces a hip model out of plastic all at once and additionally attaches SS-41 steel plates processed into the shape of the hip to make the mass of the model similar to the human body.

Hair Segmentation using Optimized Fully Connected Network and 3D Hair Style

  • Kim, Junghyun;Lee, Yunhwan;Chin, Seongah
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.385-391
    • /
    • 2021
  • 3D modeling of the human body is an integral part of computer graphics. Among them, several studies have been conducted on hair modeling, but there are generally few studies that effectively implement hair and face modeling simultaneously. This study has the originality of providing users with customized face modeling and hair modeling that is different from previous studies. For realistic hair styling, We design and realize hair segmentation using FCN, and we select the most appropriate model through comparing PSPNet, DeepLab V3+, and MobileNet. In this study, we use the open dataset named Figaro1k. Through the analysis of iteration and epoch parameters, we reach the optimized values of them. In addition, we experiment external parameters about the location of the camera, the color of the lighting, and the presence or absence of accessories. And the environmental analysis factors of the avatar maker were set and solutions to problems derived during the analysis process were presented.

Application of the Health Risk Models Estimating Skin Cancer Caused by UVB Radiation (자외선(UVB) 노출 증가에 대한 피부암 위해도 예측 모델의 적용)

  • Shin, Dong-Chun;Lee, Jong-Tae;Chung, Yong;Kang, Na-Kyung;Yang, Ji-Yeon
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.1-10
    • /
    • 1996
  • A decrease in stratospheric ozone probably caused by chloroflurocarbons (CFCs) emissions, has been observed large parts of-the globe. It is generally accepted that if ozone levels in the stratosphere are depleted, greater amounts of shortwave ultraviolet radiationB (UVB) will reach the earth's surface, resulting in increased incidence of nonmelanoma skin cancer. In this study, we evaluated several mathematical models, such as a power and an exponential model, and a geometric model considering the surface area of a human body part and ages for the prediction of Skin cancer incidence caused by exposure to the UVB radiation. These models basically estimated the risk of skin cancer based on those measurements of the local ozone in stratosphere and UVB. Both were measured at a part of Seoul with a Dobson ozone spectrometer and Robertson-Berger UV Biometer for 1995. As a result, we calculated the point estimation applying a biological amplification factor (BAF), UVB radiation and other factors. We used a Monte-Carlo simulation technique with assumption on the distribution of each considered factor. The sensitivity analysis of model by there components conducted using Gaussian sensitivity method. The annual integral of UVB radiation was 2275 MED (minimal erythema dose)/yr. Also, an estimate of the annual amount of UVB reaching the earth's surface at a korea's latitude and altitude was 3328 MED/yr. The values of the radiation amplification factor (RAF) were ranged from 0.9 to 1.5 in Seoul. To give the effective factors required to model the prediction of skin cancer incidence caused by exposure to the UVB radiation in Korea, we studied the pros and cons of above mentioned models with the application of those parameters measured in Seoul, Korea.

  • PDF

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback 방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1079-1083
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMSIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flvback method, we can isolate the 1ow voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STD). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.469-472
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flyback method, we can isolate the low voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STll-883D). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

  • PDF

A New Murine Liver Fibrosis Model Induced by Polyhexamethylene Guanidine-Phosphate

  • Kim, Minjeong;Hur, Sumin;Kim, Kwang H.;Cho, Yejin;Kim, Keunyoung;Kim, Ha Ryong;Nam, Ki Taek;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • v.30 no.2
    • /
    • pp.126-136
    • /
    • 2022
  • Liver fibrosis is part of the wound healing process to help the liver recover from the injuries caused by various liver-damaging insults. However, liver fibrosis often progresses to life-threatening cirrhosis and hepatocellular carcinoma. To overcome the limitations of current in vivo liver fibrosis models for studying the pathophysiology of liver fibrosis and establishing effective treatment strategies, we developed a new mouse model of liver fibrosis using polyhexamethylene guanidine phosphate (PHMG-p), a humidifier sterilizer known to induce lung fibrosis in humans. Male C57/BL6 mice were intraperitoneally injected with PHMG-p (0.03% and 0.1%) twice a week for 5 weeks. Subsequently, liver tissues were examined histologically and RNA-sequencing was performed to evaluate the expression of key genes and pathways affected by PHMG-p. PHMG-p injection resulted in body weight loss of ~15% and worsening of physical condition. Necropsy revealed diffuse fibrotic lesions in the liver with no effect on the lungs. Histology, collagen staining, immunohistochemistry for smooth muscle actin and collagen, and polymerase chain reaction analysis of fibrotic genes revealed that PHMG-p induced liver fibrosis in the peri-central, peri-portal, and capsule regions. RNA-sequencing revealed that PHMG-p affected several pathways associated with human liver fibrosis, especially with upregulation of lumican and IRAK3, and downregulation of GSTp1 and GSTp2, which are closely involved in liver fibrosis pathogenesis. Collectively we demonstrated that the PHMG-p-induced liver fibrosis model can be employed to study human liver fibrosis.

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

Human Postural Dynamics in Response to the Horizontal Vibration

  • Shin Young-Kyun;Fard Mohammad A.;Inooka Hikaru;Kim Il-Hwan
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • The dynamic responses of human standing postural control were investigated when subjects were exposed to long-term horizontal vibration. It was hypothesized that the motion of standing posture complexity mainly occurs in the mid-sagittal plane. The motor-driven support platform was designed as a source of vibration. The AC Servo-controlled motors produced anterior/posterior (AP) motion. The platform acceleration and the trunk angular velocity were used as the input and the output of the system, respectively. A method was proposed to identify the complexity of the standing posture dynamics. That is, during AP platform motion, the subject's knee, hip and neck were tightly constrained by fixing assembly, so the lower extremity, trunk and head of the subject's body were individually immovable. Through this method, it was assumed that the ankle joint rotation mainly contributed to maintaining their body balance. Four subjects took part in this study. During the experiment, the random vibration was generated at a magnitude of $0.44m/s^2$, and the duration of each trial was 40 seconds. Measured data were estimated by the coherence function and the frequency response function for analyzing the dynamic behavior of standing control over a frequency range from 0.2 to 3 Hz. Significant coherence values were found above 0.5 Hz. The estimation of frequency response function revealed the dominant resonance frequencies between 0.60 Hz and 0.68 Hz. On the basis of our results illustrated here, the linear model of standing postural control was further concluded.

A study on the determination of the instantaneous center of rotation pathway and the movement of the mandible by using the B-spline method (B-splint법에 의한 순간 회전 중심로 결정과 하악운동에 관한 연구)

  • Kang, Dong-Wan;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.55-81
    • /
    • 1989
  • Recently the instantaneous center concept has been to understand the biomechanics by which a tissue derangement causes a mechanical derangement in human joint. Therefore, to understand the biomechanics of temporomandibular joint (T.M.J.) as a part of human joint, it is necessary to clarify the instantaneous center of rotation (I.C.R.) in the mandibular movement. Twenty male subjects without T.M.J. disorder and mandibular deviation during the mandibular movement were selected for this study. The habitual opening and closing paths were recorded on the paper of the sagittal metal plate by two pencil markers connected to the resin open clutch attached on the lower teeth, which was designed for this study. The coordinates of the 33-target points and the 109-anatomical landmarks were obtained using a Summagraphic digitizer connected to a 18AT computer. The original raw data of the opening and closing paths were smoothed by B-spline curve fitting technique and then the I.C.R. pathways were determined mathematically by the computer using algorithm for finding the I.C.R. of a planer rigid body model. Also the opening and closing movements of the mandible were simulated according to the determined I.C.R. The results obtained from this study were as follows. 1. At the early opening and the last closing, I.C.R's were almost distributed around the mastoid process outside the mandibular body without the presence in the region of the mandibular condyle. 2. The I.C.R. pathway showed variable patterns to each subject at the opening and closing movements. 3. The K constant with uniform pattern was obtained by the rotation angle times the radius, which was assumed to the index of the mandibular movement. 4. The opening and closing movements of the mandible were simulated by the I.C.R. pathways at the habitual opening and closing movements. 5. The mandibular condyle was rotated or translated accordng to the relative rotation angle and radius of the determinant factors of K contant.

  • PDF

Analysis of Human Body Suitability for Mattresses by Using the Level of PsychoPhysiological Relaxation and Development of Regression Model

  • Min, Seung Nam;Kim, Jung Yong;Kim, Dong Joon;Park, Yong Duck;Kim, Seoung Eun;Lee, Ho Sang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.199-215
    • /
    • 2015
  • Objective: The purpose of this study is to find the level of physical relaxation of individual subject by monitoring psychophysiological biofeedback to different types of mattresses. And, the study also aims to find a protocol to make a selection of the best mattress based on the measured information. Background: In Korea, there are an increasing number of people using western style bed. However, they are often fastidious in choosing the right mattress for them. In fact, people use their past experience with their old mattress as well as the spontaneous experience they encounter in a show room to finally decide to buy a bed. Method: Total five mattresses were tested in this study. After measuring the elasticity of the mattresses, they were sorted into five different classes. Physiological and psychological variables including Electromyography (EMG), heart rates (HR), oxygen saturations (SaO2) were used. In addition, the peak body pressure concentration rate was used to find uncomfortably pressured body part. Finally, the personal factors and subjective satisfaction were also examined. A protocol was made to select the best mattress for individual subject. The selection rule for the protocol considered all the variables tested in this study. Results: The result revealing psychological comfort range of 0.68 to 0.95, dermal comfort range of 3.15 to 6.07, back muscle relaxation range of 0.25 to 1.64 and personal habit range of 2.0 to 3.4 was drawn in this study. Also a regression model was developed to predict biofeedback with the minimal use of biofeedback devices. Moreover results from the proposed protocol with the regression equation and subjective satisfaction were compared with each other for validation. Ten out of twenty subjects recorded the same level of relaxation, and eight subjects showed one-level difference while two subjects showed two-levels difference. Conclusion: The psychophysiological variables and suitability selection process used in this study seem to be used for selecting and assessing ergonomic products mechanically or emotionally. Application: This regression model can be applied to the mattress industry to estimate back muscle relaxation using dermal, psychophysiology and personal habit values.