• Title/Summary/Keyword: hpaD

Search Result 85, Processing Time 0.028 seconds

Lectin Histochemistry and Morphological Changes in von Ebner's Glands in Rats after Glossopharyngeal or Hypoglossal Axotomy (혀인두신경 또는 혀밑신경을 절단한 흰쥐 미각샘의 형태학적 변화와 렉틴조직화학)

  • Moon, Yong-Suk
    • Journal of Life Science
    • /
    • v.23 no.12
    • /
    • pp.1541-1552
    • /
    • 2013
  • The purpose of this study was to investigate the structure and secretory function of the von Ebner's gland in parasympathetic or sympathetic nerve innervation. Sprague Dawley rats were sacrificed 3, 7, 10, 14, and 21 days after bilateral glossopharyngeal or hypoglossal nerve axotomy, respectively. The circumvallate papilla portion of the tongue was dissected and we observed morphological changes in the von Ebner's gland. The properties of glycoconjugate in the von Ebner's gland were investigated using nine biotinylated lectins (PSA, UEA I, GSL I $B_4$, ECL, DBA, SBA, HPA, SJA, or sWGA). Compared with the control group, cytoplasmic vacuoles appeared in the serous acini of the von Ebner's gland in the 3-day group, and the serous acini were significantly vacuolized and degenerated in the 10-day group after glossopharyngeal nerve axotomy. However, the structure of the von Ebner's gland did not change after hypoglossal nerve axotomy. In the control group, the von Ebner's glands secreted glycoconjugates containing ${\alpha}$-D-galactose, N-acetyl-D-galactosamine, and N-acetyl-D-glucosamine oligomer, and the amount of the secretion decreased significantly in the 10-day group after glossopharyngeal nerve axotomy. However, the amount of the glycoconjugate secretion did not change after hypoglossal nerve axotomy. Therefore, the results of this study suggest that the glossopharyngeal nerve containing parasympathetic nerve fibers is important for maintaining the structure of and secretory function in the von Ebner's gland in rats.

A Ka-Band 6-W High Power MMIC Amplifier with High Linearity for VSAT Applications

  • Jeong, Jin-Cheol;Jang, Dong-Pil;Yom, In-Bok
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.546-549
    • /
    • 2013
  • A Ka-band 6-W high power microwave monolithic integrated circuit amplifier for use in a very small aperture terminal system requiring high linearity is designed and fabricated using commercial 0.15-${\mu}m$ GaAs pHEMT technology. This three-stage amplifier, with a chip size of 22.1 $mm^2$ can achieve a saturated output power of 6 W with a 21% power-added efficiency and 15-dB small signal gain over a frequency range of 28.5 GHz to 30.5 GHz. To obtain high linearity, the amplifier employs a class-A bias and demonstrates an output third-order intercept point of greater than 43.5 dBm over the above-mentioned frequency range.

Evaluation of function and disorders of the adrenal gland in neonates (신생아에서의 부신기능 평가와 질환)

  • Hwang, Il Tae
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.236-240
    • /
    • 2007
  • Majority of sick full term newborns have adequate adrenal cortical function in response to stress. Acutely ill neonates with a basal cortisol level less than $15{\mu}g/dL$ (414 nmol/L) suggest adrenal insufficiency and require function testing of adrenal function. In premature infant, immaturity of hypothalamic-pituitary adrenal axis (HPA axis), may limit the ability to increase cortisol production in response to stress. The response to low dose ACTH and CRH appears to be useful as an additional test of adrenal function. CRH stimulation has been used increasingly in neonates. The ACTH and CRH stimulated cortisol response of more than $17{\mu}g/dL$ (469 nmol/L) indicates a normal response.

A Study on Implementation of Linear 25Watts High Power Amplifier for VDR (VDR을 위한 선형 25Watts 고출력 증폭기 구현에 관한 연구)

  • Choi, Jun-Su;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.389-391
    • /
    • 2011
  • This paper has been studied about design of linear 25Watt Power amplifier for VDR(VHF Data Radio). VDR's frequency band is 117.975~137MHz, and CSMA(Carrier Sense Multiple Access), D8PSK(Differential Eight Phase Shift Keyed), 25KHz's channel bandwidth use. It also stated in DO-281A MOPS output power, symbol constellation error, spurious emissions, adjacent channel power must be met. HPA is designed to meet DO-281A standard.

  • PDF

W-CDMA 30 Watts High Power Amplifier Using Anti-Phase Intermodulation Distortion Linearization Technology (Anti-Phase IMD 선형화 기술을 이용한 W-CDMA 30 W 대전력 증폭기)

  • Kang, Won-Tae;Do, Ji-Hoon;Chang, Jeong-Seok;Hong, Ui-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.723-730
    • /
    • 2007
  • This paper shows how the ACLR of power amplifier can be reduced by using Anti-phase IMD linearization technique which generate anti-phase IMD in the driver stage compare to output stage's IMD. And design process proposed. From the experimental result of W-CDMA 4FA input signal, this amplifier has ACLR -55 dBc@5 MHz offset at 30 watts average power. Compare to optimum matching technique to get maximum power gain, this technique has been improved ACLR by 12 dBc. Also this amplifier meets 50 watts average output power amplifier specification in domestic market.

AlGaN/GaN Based Ultra-wideband 15-W High-Power Amplifier with Improved Return Loss

  • Jeong, Jin-Cheol;Jang, Dong-Pil;Shin, Dong-Hwan;Yom, In-Bok;Kim, Jae-Duk;Lee, Wang-Youg;Lee, Chang-Hoon
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.972-980
    • /
    • 2016
  • An ultra-wideband microwave monolithic integrated circuit high-power amplifier with excellent input and output return losses for phased array jammer applications was designed and fabricated using commercial $0.25-{\mu}m$ AlGaN/GaN technology. To improve the wideband performance, resistive matching and a shunt feedback circuit are employed. The input and output return losses were improved through a balanced design using Lange-couplers. This three-stage amplifier can achieve an average saturated output power of 15 W, and power added efficiency of 10% to 28%, in a continuous wave operation over a frequency range of 6 GHz to 18 GHz. The input and output return losses were demonstrated to be lower than -15 dB over a wide frequency range.

Ka-band Compact AESA Antenna Unit Design for Seeker

  • Bongmo Kang;Ikjong Bae;Jaesub Han;Youngwan. Kim;Jaehyun Shin;Jihan Joo;Seonghyun Ryu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.330-338
    • /
    • 2024
  • In this paper, a Ka-band high-output active phased array antenna device applicable to small radars and seekers was designed, and the improved performance was studied. The radiation device assembly consists of 1x8 arrangements, and the step flared notch antenna type. It shows low active reflection loss characteristics in broadband, and low loss characteristics by applying the air-strip feeding structure, and is designed to enable beam steering up to 45 degrees. The TRM(transmit receive module) output power is more than 2.0W per channel using GaN HPA in the transmitting path, and satisfies more than 25.0 dB gain and less than 6.0 dB noise figure in the receiving path. Accordingly, the Effective Isotropically Radiated Power(EIRP) of the antenna unit shows the performance of 0.00 dB or more and the receive gain-to-noise temperature ratio(G/T) of 0.00 dB/k or more. For demonstration, we have designed aforementioned planar array antenna which consists of 64 radiating elements having a size within 130 mm x 130 mm x 300 mm and weight of less than 4.9 kg..

Compensation of Phase Noise and IQ Imbalance in the OFDM Communication System of DFT Spreading Method (DFT 확산 방식의 OFDM 통신 시스템에서 위상잡음과 직교 불균형 보상)

  • Ryu, Sang-Burm;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • DFT-spread OFDM(Discrete Fourier Transform-Spread Orthogonal Frequency Division Multiplexing) is very effective for solving the PAPR(Peak-to-Average Power Ratio) problem. Therefore, the SC-FDMA(Single Carrier-Frequency Division Multiple Access) which is basically same to the DFT spread OFDM was adopted as the uplink standard of the 3GPP LTE ($3^{rd}$ Generation Partnership Project Long Term Evolution). Unlike the ordinary OFDM system, the SC-FDMA using DFT spreading method is vulnerable to the ICI(Inter-Carrier Interference) problem caused by the phase noise and IQ(In-phase/Quadrature) imbalance and effected FDE(Frequency Domain Equalizer). In this paper, the ICI effects from the phase noise and IQ imbalance which can be problems in uplink transmission are analyzed according the back-off level of HPA. Next, we propose the equalizer algorithm to remove the ICI effects. This proposed equalizer based on the FDE can be considered as up-graded and improved version of PNS(Phase Noise Suppression) algorithm. This proposed equalizer effectively compensates the ICI resulting from the phase noise and IQ imbalance. Finally, through the computer simulation, it can be shown that about SNR=14 dB is required for the $BER=10^{-4}$ after ICI compensation when the back-off is 4.5 dB, $\varepsilon=0.005$, $\phi=5^{\circ}$, and $pn=0.06\;rad^2$.

Differential Diagnosis of Hyperphenylalaninemias (고페닐알라닌혈증의 진단 및 평가)

  • Lee, Jeongho
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.110-117
    • /
    • 2015
  • All infants should be screened for phenylketonuria (PKU) within the three days of life, in order to allow timely dietary intervention to protect children with PKU from neurologic damage in Korea. A commonly used cut-off level for diagnosis of PKU is $240{\mu}mol/L$ (4 mg/dL). Up to 2% of cases of hyperphenylalaninemias (HPA) detected by the screening test will account for a disorder of $BH_4$ metabolism. Therefore, analysis of blood or urinary pterins is essential, backed up with measurement of DHPR activity, as this allows differentiation of $BH_4$ disorders. A $BH_4$ loading test and measurement of neurotransmitters in CSF provide further important information to the severity of $BH_4$ deficiency and $BH_4$ loading test can detect patients with $BH_4$ deficiency and $BH_4$ responsive PKU. Several protocols for $BH_4$ loading test have been described, involving treatment with $BH_4$ for periods ranging from 1 day to 1 month, and using doses of $BH_4$ of 10-20 mg/kg. There is general agreement that a reduction on blood phenylalanine of at least 30% in response to $BH_4$ loading indicates a clinically significant effect, although in some tests a lower cut-off value may be defined for individual patients, or no specific cut-off value is proposed. The frequency of $BH_4$ responsiveness is highest in patients with mild HPA and mild to moderate PKU resulting from PAH mutations with residual activity.

A Power Amplifier for Portable Base Stations Operating in TVWS (TVWS를 이용하는 이동기지국용 전력증폭기)

  • Kang, Sanggee
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.110-114
    • /
    • 2017
  • Using a small mobile wireless network as a supplement to the disaster safety network can be useful for eliminating small radio shadowing areas, reducing traffic overloads in disaster areas, and quickly building a disaster communication network in difficult access areas. Potable base station is needed to build a small mobile wireless network, and the portable base station using TVWS(TV White Space) is effective in terms of utilization of radio frequency resources and construction cost of wireless networks. In this paper, we design and implement a power amplifier for portable base station operating in TVWS. The implemented power amplifier operates at 470 ~ 698MHz. The gain of the implemented amplifier is more than 20.1dB, the input/output return loss is more than 11.4dB, and the isolation is more than 39.9dB when the output is off. The IMD characteristic of the power amplifier has characteristics of 61.0dBc with 18.8dBm output at 470MHz, 59.3dBc wih 18.6dBm output at 550MHz and 56.5dBc with 19.0dBm output at 690MHz. The power amplifier implemented in this paper can be used as a power amplifier for portable base station.