Performance Comparison of Butterfly Joints between Manual Member and Pre-cut Member (수가공 및 기계가공 된 나비장 접합부의 성능 비교)

  • Kim, Gwang-Chul;Kim, Jun-Ho
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.3
    • /
    • pp.165-174
    • /
    • 2016
  • To modularize the joints of Hanok, the bending strengths of butterfly joints between pre-cut and manual member were compared. Structural size joints were manufactured and the length, width and thickness of each tenon were produced with different sizes. The ultimate load of pre-cut members was 2 times higher than that of manual members. Degree of anchorage for the joints on pre-cut member was also superior to that of manual member. By the F-test results, a great influence between ultimate load and sizes of tenon was found. In result of multiple regression analysis, the length and thickness of tenon were showed proportion relationships with the ultimate load, but the width of tenon was showed inverse proportion with the ultimate load. The results of this study can be used to identify the relationships among the major influence factors. Futhermore, it might be used as basic data for modularization the joints of Hanok.

Experimental Studies and Detailing Suggestion for Reinforced Concrete Slabs with Steps (단차가 있는 철근콘크리트 슬래브의 구조성능 평가 실험 및 상세 제안)

  • Kim, Sang-Hee;Hong, Geon-Ho;Park, Hong-Gun;Han, Kyoo-Beom;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.447-455
    • /
    • 2013
  • In this study, reinforced concrete slabs with steps were experimentally studied to analyze their structural performance and to suggest reinforcing details in the step. Because the stepped slabs may behave very poorly in terms of bending strength, stiffness, deflection, cracking, etc., the study is aimed to suggest proper reinforcing details such that the same bending strength is obtained as that without steps. The bending strengths of 12 test specimens with a variety of different reinforcing detail types or other parameters were compared with each other. The specimen without any additional reinforcement in the step had a very low bending strength and significant damage, and the specimens with diagonal reinforcements in the step showed substantial early cracks, experienced hinging of the step, and had a substantial loss of the bending strength. In contrast, the specimens with a combination of U-bars, reversed U-bars, L-bars, and reversed L-bars performed very well and almost reached to 100% of the slab bending strength. The U-bars and reversed U-bars were effective in controling the diagonal cracks, while the L-bars and reversed L-bars were effective in preventing from yielding of slab reinforcement near the step.

Development of high-performance heavy density concrete using different aggregates for gamma-ray shielding

  • Ouda, Ahmed S.
    • Advances in materials Research
    • /
    • v.3 no.2
    • /
    • pp.61-75
    • /
    • 2014
  • This study aimed to investigate the suitability of some concrete components for producing "high-performance heavy density concrete" using different types of aggregates that could enhances the shielding efficiency against ${\gamma}$-rays. 15 mixes were prepared using barite, magnetite, goethite and serpentine aggregates along with 10% silica fume, 20% fly ash and 30% blast furnace slag to total OPC content for each mix. The mixes were subjected to compressive strength at 7, 28 and 90 days. In some mixes, compressive strengths were also tested up to 90 days upon replacing sand with the fine portions of magnetite, barite and goethite. The mixes containing magnetite along with 10% SF reaches the highest compressive strength exceeding over M60 requirement by 14% after 28 days. Whereas, the compressive strength of concrete containing barite was very close to M60 and exceeds upon continuing for 90 days. Also, the compressive strength of high-performance concrete incorporating magnetite fine aggregate was significantly higher than that containing sand by 23%. On the other hand, concrete made with magnetite fine aggregate had higher physico-mechanical properties than that containing barite and goethite. High-performance concrete incorporating magnetite fine aggregate enhances the shielding efficiency against ${\gamma}$-rays.

Use of e-plastic waste in concrete as a partial replacement of coarse mineral aggregate

  • Sabau, Marian;Vargas, Johnny R.
    • Computers and Concrete
    • /
    • v.21 no.4
    • /
    • pp.377-384
    • /
    • 2018
  • The accelerated increase of the population growth rate in the world and the current lifestyle based on consumerism considerably increased the amount of waste generated by the human activity. Specifically, e-plastic waste causes significant damage to the environment because of its difficult degradation process. This paper aims to establish the feasibility of using e-plastic waste in concrete as a partial replacement of coarse mineral aggregate. Considering a control mix without e-plastic waste designed for a compressive strength of 21 MPa, tests on concrete mixes with 40, 50 and 60% of e-plastic waste aggregate to determine the fresh and hardened properties were carried out. A reduction in the compressive strength as the percentage of e-plastic waste increases was observed, the maximum reduction being 44% with respect to the control mix. In addition, a significant reduction as much as 22% in the density of the concrete mixes with e-plastic waste was recorded, which means that lighter elements can be produced with this type of concrete. Two new equations based on regression analysis of the experimental data from this study were proposed. These equations estimate the reduction in the compressive strength of concrete mixes with e-plastic waste aggregate at 14 and 28 days. A cost analysis and a practical alternative to introduce this waste material into the market are also presented.

The Effects of Plasma Treatments on the Surface Energy of the Polycarbonates and on the Adhesion Strength of the Cu Film/Polycarbonate Interface (플라즈마 표면처리에 의한 폴리카보네이트의 표면에너지 및 구리박막과의 접착력 변화에 관한 연구)

  • Cho Byeong-Hoon;Lee Won-Jong;Park Young-Ho
    • Korean Journal of Materials Research
    • /
    • v.15 no.11
    • /
    • pp.745-750
    • /
    • 2005
  • Polycarbonates are widely used as housing materials of electronic handsets. Since the polycarbonate is electrically insulating, there should be a conducting layer on the polycarbonate for EMI shielding. In this study, we sputter deposited Cu films on the polycarbonate substrates for EMI shielding. Plasma treatments of polycarbonates were used to increase the adhesion strength of the Cu film/polycarbonate interface. The surface energy of the polycarbonate was greatly increased from $30mJ/m^2 \;to\; 65mJ/m^2$ by a 200 W $O_2$ plasma treatment for 10s. It is thought that this is because of the ion bombardment. The adhesion strength of the sputter deposited Cu film to the polycarbonate was quantitatively measured by a 4 point bending tester. A moderate plasma surface treatment of the polycarbonate increased the Cu film/polycarbonate adhesion strength by $30\%$. The EMI shielding efficiency of the sputter deposited $10{\mu}m$ Cu lam on the polycarbonate showed 90dB in the range of 100MHz to 1000MHz.

Performance of aerated lightweighted concrete using aluminum lathe and pumice under elevated temperature

  • Mohammad Alharthai;Yasin Onuralp Ozkilic;Memduh Karalar;Md Azree Othuman Mydin;Nebi Ozdoner;Ali Ihsan Celik
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.271-288
    • /
    • 2024
  • The primary objective of this study is to investigate the production and performance characteristics of structural concrete incorporating varying proportions (0%, 25%, and 50% by volume) of pumice stone, as well as aluminum lathe as an additive at 0%, 1%, 2%, and 3%, under fire conditions. The experiment will be conducted over a period of up to 1 hour, at temperatures ranging from 24℃, 200℃, 400℃ and 600℃. For the purpose of this, a total of twelve test samples were manufactured, and then tests of compressive strength (CS), splitting tensile strength (STS), and flexural strength (FS) were performed on these samples.Next, a comparison was made between the obtained values and the influence of temperature. To achieve this objective, the manufactured samples were placed at temperatures of 200℃, 400℃, and 600℃ for a duration of 1 hour, and were subjected to the influence of temperature.These values at 24 ℃ were then contrasted with the CS results obtained from test samples that were subjected to the temperature effect for an hour at 200 ℃, 400 ℃, and 600 ℃. A comprehensive analysis of the test outcomes reveals that the incorporation of aluminum lathe wastes into a mixture results in a significant reduction in the compressive strength of the concrete. As a result of this adjustment, the CS values dropped by 32.93%, 45.70%, and 52.07%, respectively. Furthermore, It was shown that testing the ratios of pumice stone alone resulted in a decrease in CS outcomes. Additionally, it was found that the presence of higher temperatures is clearly the primary factor contributing to the decrease in the strength of concrete. Due to elevated temperatures, the CS values decreased by 19.88%, 28.27%, and 38.61% respectively.After this investigation, an equation that explains the connection between CS and STS was provided through the utilization of the data of the experiments that were carried out.

Effect of Housing Systems - Barn vs Cage on the First Phase Egg Production and Egg Quality Traits of Laying Pullet

  • Ahammed, Musabbir;Ohh, Sang Jip
    • Korean Journal of Poultry Science
    • /
    • v.40 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • With an increasing concern on laying hen welfare, barn system has appeared as one of the alternatives to replace the conventional cage. This study was conducted to compare the early laying performance and egg quality at the barn system with those at the conventional cage. A total of 288 shaver-579 brown layers were used for 9 weeks ($21^{st}$ to $30^{th}$ weeks of age) feeding study. Feed consumption and egg weight were significantly (P<0.01) higher at barn than at cage. However, there were no significant differences between two housing systems on hen day egg production (HDEP), egg mass, body weight, feed efficiency and livability. In case of egg quality parameters, shell thickness, albumen height and Haugh unit were significantly (P<0.05) different between two systems. Haugh unit and albumen height were significantly higher in eggs produced at cage (88.97 and 8.16 mm) compared than those produced at barn (83.11 and 6.87 mm), whereas shell thickness was thicker in eggs produced at barn than those produced at cage. Shape index, breaking strength, blood spots and yolk index data were not influenced significantly by the types of housing system. To implement welfare bestowing production, this study showed that the barn system can replace the conventional cage without serious sacrifices on starting phase egg production. In addition, this study suggested that the barn system need to be optimized in view of daily feed consumption.

Marketing Strategy and Influential Factors based on the Attributes of Unit Modular System (유닛 모듈러 공법의 특성요인 분석 및 시장진출전략)

  • Kim, Domin;Lee, Jeongseok;Kim, Juhyung;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.78-86
    • /
    • 2014
  • Modular system is a construction method which installs factory-manufactured units on site. It enables to reduce the duration and improve the quality of the construction. Nevertheless, the unit modular system is restrictively applied to domestic market such as barracks, education facilities, low-rise housing. To motivate the application of unit modular system, this study figures out important attributes of the unit modular system in a domestic construction market. Finally this study suggest marketing strategies and influential factors by Importance-Performance Analysis(IPA) based on those attributes focusing on the apartment housing. As a result, Unit modular System in the domestic market has strength on constructability, but it show weakness on usability and economic aspects which are more important in apartment housing market. Thus an improved technology in usability and economic aspects are required to activate the market.

Tests for Imbalance between Variations in Metropolis Housing Prices by Regulatory Realty Policies (부동산 규제정책에 따른 광역 주택가격의 변동간 불균형 검정)

  • Kim, Tae-Ho;Ann, Ji-Hee
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.3
    • /
    • pp.457-469
    • /
    • 2010
  • The government real estate policy has repeatedly relaxed and reinforced controls under the mutually contradictory targets. Switching over the supporting policy after the IMF crisis to the regulating policy from 2003, the government housing policy began to generate ill effects due to various regulations. This stud carefully investigates and statistically tests the transmissions of variations in the housing prices between the metropolitan areas in the early stage of the preceding administration, under the effect of the supporting scheme, and those in the late stage, under the effect of the restricting scheme. The distinctive feature between the two periods is found to be much simplified interrelationships of the price variations in the latter period. Consolidated leading role of capital sphere, by concentrated economic strength, suggest the obvious imbalance between variations in the metropolis housing prices.

An Assessment Study of Seismic Resistance of Two-story Wood-frame Housing by Shaking Table Tests

  • Ni, Chun;Kim, Sang-Yeon;Chen, Haijiang;Lu, Xilin
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • While there exists a relatively large body of technical information for the engineered design of wood-frame buildings to resist seismic ground motions, the quantitative assessment of seismic resistance of conventional houses built by prescriptive requirements is less well understood. Forintek Canada Corp., in collaboration with other research and industry partners, has embarked on a research project to address this topic. This paper will report on the seismic shake table tests of a full-scale wood-frame building. The two-story specimen, $6m{\times}6m$ in plan, was built on the seismic shake table at Tongji University in Shanghai, China, according to Part 9 of the 1995 National Building Code of Canada and shaken uni-directionally in each of the two principal directions. Three different seismic table motions were applied at increasing peak ground motion amplitudes up to 0.40 and 0.50 g. The specimen was repaired after the above sets of seismic table motions, and successive runs were conducted for increased door openings. Measurements included specimen accelerations, displacements and anchorage forces. Static stiffness of the specimen was measured at low force levels, and natural frequencies were measured after each seismic loading stage by applying low-level random excitation. The results presented consist of the capacity spectra of the shake table tests, changes in specimen stiffness and natural frequencies with increasing seismic loading. These results and those from other recent shake table tests elsewhere will be compared with simplified engineering calculations based on codified values of strength, and on that basis preliminary conclusions will be drawn on the adequacy of the current code provisions and design guides in Canada and the USA for conventional wood-frame construction.