• Title/Summary/Keyword: housing condition

Search Result 737, Processing Time 0.026 seconds

Estimation of resistance coefficient of PHC bored pile by Load Test II (재하시험에 의한 PHC 매입말뚝의 저항계수 산정 II)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • In Europe and the United States, the use of limit states design has almost been established for pile foundation design. According to the global trend, the Ministry of Land, Transport and Maritime Affairs has established the basic design criteria of the bridge under the limit state design method. However, it is difficult to reflect on the design right now because of lack of research on resistance coefficient of the pile method and ground condition. In this study, to obtain the resistance coefficient of PHC bored pile which is widely used in Korea, the bearing capacity calculated by the LH design standard and the bridge design standard method, the static load test(21 times) and the dynamic load test(EOID 21 times, Restrike 21) The reliability analysis was performed on the results. The analysis of the resistance coefficient of PHC bored pile by loading test was analyzed by adding more than two times data. As a result, the resistance coefficient obtained from the static load test(ultimate bearing capacity) was 0.64 ~ 0.83 according to the design formula and the target reliability index, and the resistance coefficient obtained from the dynamic load test(ultimate bearing capacity) was 0.42~0.55. Respectively. The resistance coefficient obtained from the modified bearing capacity of dynamic load test(EOID's ultimate end bearing capacity + restrike's ultimate skin bearing capacity) was 0.55~0.71, which was reduced to about 14% when compared with the resistance coefficient obtained by the static load test(ultimate bearing capacity). As a result of the addition of the data, the resistivity coefficient was not changed significantly, even if the data were increased more than 2 times by the same value or 0.04 as the previous resistance coefficient. In conclusion, the overall resistance coefficient calculated by the static load test and dynamic load tests in this study is larger than the resistance coefficient of 0.3 suggested by the bridge design standard(2015).

Effects of Crossbreeding and Gender on the Carcass Traits and Meat Quality of Korean Native Black Pig and Duroc Crossbred

  • Muhlisin, Muhlisin;Panjono, Panjono;Lee, Sung-Jin;Lee, Jeong Koo;Lee, Sung Ki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.1019-1025
    • /
    • 2014
  • This study was conducted to observe the effects of crossbreeding and gender on the carcass traits and meat quality of Korean Native Black Pig (KNP) and $KNP{\times}Duroc$ crossbred ($KNP{\times}D$). A total of 50 pigs comprising seven KNP barrows, eight KNP gilts, twenty $KNP{\times}D$ barrows and fifteen $KNP{\times}D$ gilts were used in this study. Animals were reared in the same housing condition with same feed diet for six months prior to slaughter. After an overnight chilling, the carcasses were graded, and samples of Musculus longissimus dorsi were obtained for meat quality analysis. The slaughter and carcass weights and dressing percentage of $KNP{\times}D$ were higher (p<0.001) than those of KNP. The slaughter and carcass weights and backfat thickness of barrows were higher (p<0.01) than those of gilts. There were no significant difference in carcass conformation and quality grade between KNP and $KNP{\times}D$ as well as barrow and gilt. Fat content of $KNP{\times}D$ was higher (p<0.001) than that of KNP. Fat content of barrow was higher (p<0.001) than that of gilt. There was interaction between crossbreeding and gender on the fat content. KNP gilt showed higher fat content than KNP barrow whereas $KNP{\times}D$ barrow showed higher fat content than $KNP{\times}D$ gilt. Lightness, redness, yellowness, chroma and hue angle values and color preference of meat of $KNP{\times}D$ were lower (p<0.001) than those of KNP. Redness, yellowness and chroma values of meat of barrow were lower (p<0.05) than those of gilt. It is concluded that crossbreeding KNP with Duroc increases carcass productivity and meat fat but decreases meat color values and preference. Crossbreeding of KNP with Duroc produces a better fat deposition in meat of barrows than in gilts.

The Improvement Index of Smart Public Services to Advance Information Accessibility for the Elderly (고령자 정보접근성 향상을 위한 스마트 공공서비스 지표)

  • Kim, Mi-Yun;Byun, Sung-Jun
    • Journal of Digital Convergence
    • /
    • v.16 no.5
    • /
    • pp.43-53
    • /
    • 2018
  • Recently, public service for the improvement of quality of life and life support such as safety, aging, disaster, welfare, housing, economy, urban environment, traffic etc are actively developed based on open public data, and the spread of the network and the necessity of everyday life, smartphones are playing a role in providing public services. Currently, the development of science is changing the life expectancy of human beings and changing into social structure in which aged people become bigger due to various social conditions and low fertility and aging problems. However, the elderly who do not have easy access to information are very uncomfortable in dealing with mobile devices with very low accessibility and utilization of public services provided by mobile phones. Therefore, this study recategorizes the condition of the elderly presented in the previous study and identifies the problem through case analysis provided for the elderly. Also, we summarize the hierarchy of the core items of the existing interface design and derive it as an improvement index of the public service design for the improvement of the information accessibility of the elderly, and propose a design method to improve the utilization of the public service provided through the mobile device.

A study on the Need for Introducing the Information and Communication Facilities Maintenance Mandatory System: In view of Apartment House Environment) (정보통신설비의 유지관리 의무화제도 도입 필요성에 관한 연구(공동주택환경을 중심으로))

  • Lim, Sang-Chool;Kim, Sun-Hyung
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.6 no.3
    • /
    • pp.15-24
    • /
    • 2007
  • According to an apartment house environment and the service provide method of major telecom operators, is providing optic-LAN service with installing the equipments of optical office center and optic distribution at MDF(Main Distribution Frame) and under-ground of apartment. therefore the distribute is deepening between service providers because of space securement to install equipments and spare pipe securement to reinstall UTP cable. These were reasons that operators leaned to subscriber collection and neglected to maintenance, in addition, insist the facilities invested by each operators is his own assets for all that in-plant of apartment house is private land. So, would not being touched by others. Accordingly, this study will search it through the field current condition examine that service's types and methods which various telecom operators and broadcast operators are providing, the current conditions of being maintained, the problems of being happened. etc. and would like to improve that the users could use the services safely by making the information & communication facilities maintenance mandatory under the regular size of apartment house circumstances through the analysis of various laws relations which are managed information & communication construction work law, telecommunication basis law, home network. etc. technical standards by the Ministry of Information and Communication and are managed housing law, construction law, the regulation related to house construct standards. etc. by the Ministry of Construction and Transportation.

  • PDF

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room (X선촬영실 내에서의 공간산란선량 변동에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

A Study on the Characteristics of Bearing Capacity for SIP Piles in Domestic Areas (국내 SIP 말뚝의 지지력 특성에 관한 연구)

  • Lee, Song;Park, Jun-Hong;Park, Joong-Bai;Kim, Tae-Hwoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.319-327
    • /
    • 2002
  • In this research, problems of recent design methods and their improvement for SIP(Soil-Cement Injected precast Pile) in domestic areas were studied by using the properties of load-settlement curves and bearing capacity from field loading tests. Elastic and plastic settlement for total settlement in each loading step of loading tests conducted in domestic areas has been shown to have a tendency. From this tendency and bearing capacity determined by loading tests, it could be ascertained that empirical chart could be an assistant tool in SIP design. It was shown that SIP design using N-value in domestic area with soil condition of granitic type resulted in very conservative hearing capacity. On the other hands, in soil with unfitted geological conditions, the design could be insecure. Also, we could ascertain that Meyerhof's bearing capacity using modified N-value on the tip part of pile was more applicable than recent design method where tip bearing capacity was 20NA$_p$ N-value limited to 50. These results showed that modified design method could be more economic than those in the past because it used pile's bearing capacity unto tolerable load of pile material.

Surface Checking Reduction Effect of Preservative-treated Korean Larch Round-woods with Various Physical Treatments (물리적 처리에 따른 낙엽송 방부원주목의 표면할렬 방지효과)

  • Pang, Sung-Jun;Oh, Jung-Kwon;Lee, Sang-Joon;Park, Jun-Ho;Jang, Sung-Il;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.107-115
    • /
    • 2017
  • In this study, the surface check reduction effect of preservative-treated Korean larch round-wood was investigated by applying three physical treatments, such as incising, kerfing, and kiln-drying. Moreover, the possibility of long-term service life was also checked by comparing the depth of surface check and the penetration depth of preservative. A rapid gradient of wood moisture content between surface and center causes a surface check. Thus, the effect of reducing surface check was carried out at the lowest equilibrium moisture content (EMC) condition, temperature ($2^{\circ}C$), humidity (44.6%), in outdoor locations in Korea until the test specimens reach to the 8.6% EMC. As a result, the preservative-treated specimens without incising, kerfing, kiln-drying (Type C) could not ensure the long-term service life due to a large surface check. Because the surface check depth of all specimens was deeper than the penetration depth of preservative. In case of the incising treated specimens (Type I), 80% of them, the depth of surface check was not deeper than the penetration depth of preservative. However, when a kerfing was additionally treated (Type B), a possibility of happening deeper surface check than penetration depth of preservative was increased rather than Type I.

Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle (전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가)

  • Kwak, Daehwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.634-640
    • /
    • 2020
  • Failure analysis and heat-resistant were performed for an electric fuel pump that is installed in the fuel tank to transfer fuel to the engine of combat vehicles. The fuel pump with a DC motor was disassembled and inspected to determine the cause of failure. The failure phenomenon was classified into three categories based on observations of the inside of the housing: burnt winding, quick brush abrasion, and fuel leak into the pump. Based on the inspection results, it was estimated that overheating was the main cause of failure. The thermal test was conducted under the no-load condition in 24 hours, and the thermal sensor was installed on the stator surface and the brush holder to check the possibility of damage to the winding due to overheating. When the ambient temperature of the fuel pump was set to 68 ℃, the stator temperature increased to 135.9 ℃, and the winding of the motor was almost damaged. The test results confirmed the lack of heat resistance of fuel pump windings, and suggested that the type F of insulation class (below 155 ℃) of the windings and varnish should be replaced with type C or higher that can be used above 180 ℃.

A Study on the Establishment & Functional Characteristics of Health Facilities for the Aged in Japan

  • Kim, Tae Il;Yoshida, Tomo Hiko
    • Architectural research
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Various housing measures are needed for the rapidly aging society of Korea. In particular, the welfare policy for the elderly has changed towards the community care. Taking this fact into consideration, it is necessary to have the establishment of a system that offers the elderly appropriate welfare services at their appropriate residence (ageing in place) for the effectiveness of the community care. In this aspect, there are a number of implications to Korea to study merits and demerits of the Health Facilities for the Aged (HFA) in Japan. The society of Japan has been rapidly aging since 1970, and Korea is to face the same situation. As for the data of this study, a total of 2,393 facilities (as of November 1999) mentioned in the annual report of the Japanese Ministry of Health, Labor and Welfare were classified based on types of their establishment: (1) free-standing structures (603 facilities); (2) annexes to hospitals (981 facilities); (3) annexes to welfare facilities (511 facilities); and (4) annexes to clinics (298 facilities). Next, 239 facilities were selected through taking a sample of 10 percent from each type of the HFA mentioned above. This was done through the random sampling method with the computer program of MS EXCEL. The Implications of the results of analyses are as follows. First, most of the health facilities were planned with the scale that was larger than the scale of standard special nursing homes in terms of the total floor area. Precise equations that were to obtain precise results of the scale of the HFA and the appropriate number of residents were obtained through the method of the regression analysis. Korea and Japan have similarities in terms of culture, society and family relations; however, the two countries also have differences in terms of the application of laws on the establishment of houses, hospitals, and welfare facilities. As for planning the scale of the HFA, the realities of Korea should be considered. Second, as for the functional aspect of the HFA with a condition of returning home, the place before and after the HFA showed the pattern of 'from a residential place to a residential place' and 'from a hospital to a hospital.' This reveals a close correlation with the types of the HFAs and operational ways of the facilities. Its cause is considered to be the aspect of the operation and management of the HFA rather than the aspect of its function of providing services in association with medical and health facilities. Therefore, when intermediate welfare facilities are considered in Korea, it is strongly advised to consider the problem of annexes to other facilities and efficiency of sharing of the facilities in terms of its operation and management.

A Study on Preference of Apartments Remodeling Items for Reducing Construction Waste (건설폐기물 발생저감을 위한 공동주택 리모델링 항목의 선호도에 대한 연구)

  • Chae, Kyeong-Seok;Ang, Yun-Sun;Kim, Yong-Sung;Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.2
    • /
    • pp.116-123
    • /
    • 2010
  • Since the Enforcement Decree of the Housing Act was changed in 2007, remodeling demands have increased. For this reason, many research studies are actively discussed for vitalizing remodeling, but countermeasure plan for generated construction waste is not enough. This study aims to provide basic data for the reduction plan of construction waste caused by the remodeling project through the investigation of apartments residents' priorities about remodeling elements for reducing construction waste. In this study, remodeling elements have been drawn through the literature investigation. As a result, subordinates were classified into 21 elements and superordinate were classified into 6 elements. Expert interviews were conducted to check the reliability about subordinate and superordinate elements of remodeling and the questionnaire survey were conducted to determine the residents preference of apartments remodeling elements. As a result of the questionnaire survey, we found out the characteristic of preference for apartments remodeling elements such as the period of apartment, the location and the financial condition respectively. This study presents a basic data for considering the remodeling as well as the apartment plans for the resident's preference. Further, many studies about the reduction plan of construction waste caused by the remodeling project will have to be discussed.