• 제목/요약/키워드: house-values

검색결과 348건 처리시간 0.025초

KAERI 채널형 전단벽체의 동적해석; 시스템판별, FE 모델향상 및 시간이력 응답 (Dynamic Analysis of a KAERI Channel Type Shear Wall: System Identification, FE Model Updating and Time-History Responses)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.145-152
    • /
    • 2021
  • KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is b×l×h =2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.

IR 레이저 센서 및 관성 센서를 이용한 다목적 골프 퍼팅 거리 측정기에 대한 연구 (A Study on the Multipurpose Golf Putting Range Finder using IR Razer Sensor and Inertial Sensor)

  • 신민승;강대웅;김기덕;김지환;이철선;고윤석
    • 한국전자통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.669-676
    • /
    • 2023
  • 본 논문에서는 IR 레이저 센서 및 관성 센서를 이용한 골프 퍼팅 거리 측정을 위한 다목적 골프 퍼팅 거리 측정기를 설계, 제작하였다. 거리 측정기는 골프 퍼팅 거리 측정을 위해 실외 50m 측정 범위 내에서 거리 측정과 경사도 측정, 그리고 퍼팅에 영향을 미치는 온도 측정이 가능하도록 설계하였다. 또한, 실내 30m 측정범위 내에서 길이 및 수평도를 측정함으로써 실내 작업을 지원하며, 실내 온도 이상시 웹서버와의 연동을 통해 휴대폰 사용자에 경보를 제공함으로써 실내 또는 차량 화재로부터 안전이 확보될 수 있도록 하였다. 제안된 방법의 정확성과 스마트 폰과의 연동 성능을 평가하기 위해 하나의 시작품을 제작하고 웹서버를 구축하였으며, 반복적인 실험에서 허용 가능한 5%내의 오차율을 보임으로써 유용성을 확인할 수 있었다.

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권8호
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.

확률론적 손상을 고려한 VLCC 잔류 종강도 평가 (Residual Longitudinal Strength of a VLCC Considering Probabilistic Damage Extents)

  • 남지명;정준모;박노식
    • 대한조선학회논문집
    • /
    • 제49권2호
    • /
    • pp.124-131
    • /
    • 2012
  • This paper provides prediction of ultimate longitudinal strengths of hull girder of a VLCC considering probabilistic damage extents due to collision and grounding accidents based on IMO Guideline(2003). The probability density functions of damage extents are expressed as a function of nondimensional damage variables. The accumulated probability levels of 10%, 30%, 50%, and 70% are taken into account for the damage extent estimation. The ultimate strengths have been calculated using in-house software UMADS (Ultimate Moment Analysis of Damaged Ships) which is based on the progressive collapse method. Damage indices are provided for all heeling angles due to any possible flooding of compartments from $0^{\circ}$ to $180^{\circ}$ which represent from sagging to hogging conditions, respectively. The analysis results reveal that minimum damage indices show different values according to heeling angles and damage levels.

장수명 주택의 활성화를 위한 가동칸막이벽체 개발현황 연구 (A Study on the Development and Application of Movable Partition Components for Facilitating of Long-life Housing)

  • 이성옥;김수암
    • 한국주거학회논문집
    • /
    • 제21권6호
    • /
    • pp.91-98
    • /
    • 2010
  • The purpose of this study is to develop the feasibility of movable partition wall components that are able to correspond changes of structure system and spatial configuration by the needs of residents for the activation of long-life housing. The key element of various movable partition wall components, a movable partition wall, was analyzed for problems through both as-is analysis and field installation in Korea and Japan, and then its feasibility was verified. The movable partition wall can break the uniformity of a fixed one, can integrate and separate limited space by changes in the demands of residents, can be easy to separate, and can be independent. The development of the movable partition wall is important for the realization of diverse residential space, ease of remodeling, environment adaptation, promotion of modularization, etc. It is comprised of surfacing materials, core materials, structural materials, and movable parts. The domestic movable partition wall was verified regarding the feasibility of an apartment house through on-site inspections and sound insulation tests by KOHP21, KICT. In conclusion, the construction of long-life housing that has sustainable values in the use of housing is nationally an important assignment, so as to secure good housing stock.

마이크로 가스터빈 설계 및 운전 성능 분석 : 제2부 - 압축기와 터빈 성능저하에 의한 엔진 운전 및 성능변화 (Analysis of Design and Operation Performance of Micro Gas Turbine : Part 2 - Variations in Engine's Operation and Performance Caused by Performance Degradation of Compressor and Turbine)

  • 김정호;김민재;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.30-35
    • /
    • 2015
  • This study analyzed the variations in the performance and operation of a 200 kW class micro gas turbine according to performance degradation of compressor and turbine. An in-house code, developed by the present authors and presented in the first part of these series of papers, were used for the analysis. The degradation of compressor and turbine were simulated by modifications in the their performance maps: mass flow rate, pressure ratio and efficiency were decreased from the reference values. Firstly, the variations in the operating conditions (air flow rate, pressure ratio) were predicted for the full load condition. Then, the same analysis were performed for a wide partial load operating range. The change in engine's performance (power output and efficiency) due to the component degradation was predicted. In addition, the change in the compressor surge margin, which is an important indicator for safe engine operation, was evaluated.

TIG-FSW 하이브리드 용접을 이용한 이종재 맞대기 용접부의 잔류응력 해석 (Analysis of Residual Stress on Dissimilar Butt Joint by TIG Assisted Hybrid Friction Stir Welding)

  • 방희선;노찬승;엠 에스 비조이;방한서;이윤기
    • Journal of Welding and Joining
    • /
    • 제30권2호
    • /
    • pp.47-53
    • /
    • 2012
  • This paper aimed to study and understand the mechanical phenomena of thermal elasto-plastic behavior on the dissimilar butt joint (Al 6061-T6 and STS304) by TIG assisted Friction Stir Welding. Heat conduction and residual stress analysis is carried out using in-house solver. Two-dimensional results of the heat distribution and residual stresses in dissimilar joint for particular tool geometry and material properties are presented. The predicted stress along longitudinal direction in Al 6061-T6 and STS304 are approximately between 12-15% of their respective yield strengths. A comparison is made between experimentally measured and numerically predicted equivalent residual stress values.

Effects of solanum macrocarpon (African eggplant) on haematological parameters of wistar rats exposed to urban air pollution

  • Olajire, A.A.;Azeez, L.
    • Advances in environmental research
    • /
    • 제1권2호
    • /
    • pp.109-123
    • /
    • 2012
  • Our study investigated the effects of Solanum macrocarpon (African eggplant) on haematological and biochemical parameters of male albino rats exposed to urban air pollution ($O_3$, $PM_{10}$, CO, $SO_2$, $NO_2$ and VOC). Male albino Wistar rats were exposed for 63 days either to urban air pollution without treatment (A); oral supplementation with Solanum macrocarpon given at 36 and 75 mg/kg body weight (BW), representing C and D respectively and exposed to air pollution; oral supplementation with Solanum macrocarpon given at 75 mg/kg BW after exposure to air pollution (B); or kept in animal house without exposure to air pollution (E). Animals exposed to air pollution showed significant alterations in haematological and biochemical parameters signaling that the blood and organs were badly injured. There were significant elevations in white blood cells (WBC) and its indices, reduction in red blood cells (RBC) and significant depletions of non-enzymic antioxidants, total protein and increase in lipid peroxidation values. Solanum macrocarpon supplementation in the feed of animals halted significantly the deleterious effects of air pollution, with co-administration during exposure given better results.

선설계기법을 이용한 장경간 유리온실 구조시스템 개발 (The Development of Structural System of Long-span Greenhouse Using the Pre-Engineering Building System)

  • 오명호;김용석
    • 한국방재학회 논문집
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2010
  • 최근 급속도로 가속화되는 농촌인구의 고령화 등으로 인해 농촌시설물도 기업화, 대형화, 대공간 시설물로 변경되어야 할 필요성이 있다. 이 논문에서는 현행 한국형유리온실의 대표적인 시스템인 벤로형 유리온실을 장경간화하기 위해 변단면 부재를 이용한 선설계기법을 적용하여 최적의 구조시스템을 개발하였다. 설계하중은 기존의 설계기준들을 검토하여 합리적인 값들을 적용하였다. 그 결과 스팬이 16 m 이상인 구조시스템에서 선설계기법을 적용하면 효율적이었으며 종방향 간격도 기존의 4 m 보다는 12 m로 증가시키는 것이 철골물량측면에서 유리함을 알 수 있었다.

원자로 격납건물의 3차원 구조해석시스템 (Three-Dimensional Structural Analysis System for Nuclear Containment Building)

  • 김선훈
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.235-243
    • /
    • 2010
  • 본 논문에서는 원자로 격납건물의 3차원 해석을 수행할 수 있는 구조해석 시스템을 구축하여 제시하였다. 구조해석 시스템은 고성능 평판 및 쉘 유한요소를 요소 라이브러리로 추가하였고, 비부착식 텐던과 부착식 텐던의 거동을 정확하게 모사할 수 있는 모델링방법을 포함하고 있다. 이러한 기능을 프로그래밍하고 범용 구조해석프로그램 DIANA에 접목시켜 원자로 격납건물의 비선형해석은 물론이고 내압능력 평가가 가능하다. 본 논문에서 제안한 3차원 구조해석 시스템의 신뢰성을 확인하기 위해 중수로형 원자로 격납건물의 구조해석을 수행하여 다른 기관에서 수행한 축대칭 구조해석 결과와 비교분석하였다.