• Title/Summary/Keyword: hot-point

Search Result 666, Processing Time 0.031 seconds

The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System (축열시스템의 온수이용 예측에 관한 연구)

  • Cho, W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

고추의 랄미성분 Capsaicin에 대한 효소화학적 연구 (제1보) - 메주가 Capsicin에 미치는 영향

  • 이상섭
    • YAKHAK HOEJI
    • /
    • v.3 no.1
    • /
    • pp.11-14
    • /
    • 1957
  • "Kotchujang" is a favorite food among the Korean. "Kotchujang" is a fermented food made from rice, red pepper, table salt, water, and "Maeju". "Maeju" is a fermented Soybean and is the fermentation source for Kotchujang. The freshly prepared Kotchujang is quite hot due to the hot component of red pepper, Capasaicin and it is getting to decrease the hotness resulting to the delicious and milder taste after fermation for some time (one to two months ususally at home). No one studied on this fermentation process on biochemical view-point yet.n process on biochemical view-point yet.

  • PDF

Forecasting Load Balancing Method by Prediction Hot Spots in the Shared Web Caching System

  • Jung, Sung-C.;Chong, Kil-T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2137-2142
    • /
    • 2003
  • One of the important performance metrics of the World Wide Web is how fast and precise a request from users will be serviced successfully. Shared Web Caching (SWC) is one of the techniques to improve the performance of the network system. In Shared Web Caching Systems, the key issue is on deciding when and where an item is cached, and also how to transfer the correct and reliable information to the users quickly. Such SWC distributes the items to the proxies which have sufficient capacity such as the processing time and the cache sizes. In this study, the Hot Spot Prediction Algorithm (HSPA) has been suggested to improve the consistent hashing algorithm in the point of the load balancing, hit rate with a shorter response time. This method predicts the popular hot spots using a prediction model. The hot spots have been patched to the proper proxies according to the load-balancing algorithm. Also a simulator is developed to utilize the suggested algorithm using PERL language. The computer simulation result proves the performance of the suggested algorithm. The suggested algorithm is tested using the consistent hashing in the point of the load balancing and the hit rate.

  • PDF

Control Scheme Using Forward Slip for a Multi-stand Hot Strip Rolling Mill

  • Moon, Young-Hoon;Jo, I-Seok;Chester J. Van Tyne
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.972-978
    • /
    • 2004
  • Forward slip is an important parameter often used in rolling-speed control models for tandem hot strip rolling mills. In a hot strip mill, on-line measurement of strip speed is inherently very difficult. Therefore, for the set-up of the finishing mill, a forward slip model is used to calculate the strip speed from roll circumferential velocity at each mill stand. Due to its complexity, most previous researches have used semi-empirical methods in determining values for the forward slip. Although these investigations may be useful in process design and control, they do not have a theoretical basis. In the present study, a better forward slip model has been developed, which provides for a better set-up and more precise control of the mill. Factors such as neutral point, friction coefficient, width spread, shape of deformation zone in the roll bite are incorporated into the model. Implementation of the new forward slip model for the control of a 7-stand hot strip tandem rolling mill shows significant improvement in roll speed set-up accuracy.

Study on the Development Status of Korean Hot Springs (온천관광지 개발실태 조사연구)

  • Kim, Hyun
    • Journal of Korean Society of Rural Planning
    • /
    • v.13 no.1 s.34
    • /
    • pp.85-95
    • /
    • 2007
  • Hot springs development will be more activated with the five-day work week system than before. Nevertheless, investment and development achievement of hot springs has not resulted in a successful performance to foster townships, and this calls upon locals to build a guideline to develop hot springs. This study intends to analyze laws on hot springs, which influence mostly on the hot spring development, to gather up the information on the present state of the development, and to suggest considerations for further development plans. Features of the hot spring development are as follows: One is that metropolitan cities will discover hot spring resources more than small cities. Therefore the development will be twofold : one for resort tour and the other for one-day rest and recreation. In addition, Korean laws on hot springs are more site development-oriented to support tourism and recreation than to protect environment and discover unused resources. This makes hot spring development easier and efficient being supported by hot spring law, law on territory development and use, and tourism promotion law. On the other side, planned landscape trimming can be uniformized and unharmonized in terms of local identity and environment-friendliness. This is why careful considerations such as goods and bads of the local resources, local history and culture are needed in hot spring development. A long-term development project should include remodeling based on local identity and development trends. The third point indicates that Korean hot springs development has recorded relatively low performance due to difficult private capital attraction, and a high fence on land purchase and development approval. It is essential to release restrictions on the hot spring development-especially on those whose development performance has not been successful so that best practice can be supported by the government in remodeling and marketing. New plans on hot spring development should be also examined based on developer's capacity and local authorities' volition on the plan. Last point shows that most hot springs development plans have been designed only based on territory utilizing plan and facilities arrangement, not considering much on fund-raising, operational plan or feasibility analysis. Therefore the tourism promotion law should reinforce guidelines on tourist site approval system by supplementing criteria. At the same time, an education on tourism development planning is necessary to deepen developers' understanding, since most developers are experts more on city development, landscape architecture, designing, constructing and engineering than tourism development.

Finite element modeling of rolled steel shapes subjected to weak axis bending

  • Saliba, Najib G.;Tawk, Issam;Gergess, Antoine N.
    • Steel and Composite Structures
    • /
    • v.29 no.2
    • /
    • pp.161-173
    • /
    • 2018
  • Point bending is often used for cambering and curving structural steel girders. An analytical solution, applicable in the elasto-plastic range only, that relates applied loads to the desired curve was recently developed for inducing horizontal curves using four-point bending. This solution does not account for initial residual stresses and geometric imperfections built-in hot-rolled sections. This paper presents results from a full-scale test on a hot-rolled steel section curved using four-point bending. In parallel, a numerical analysis, accounting for both initial geometric imperfections and initial residual stresses, was carried out. The models were validated against the experimental results and a good agreement for lateral offset and for strain in the elasto-plastic and post-plastic ranges was achieved. The results show that the effect of initial residual stresses on deformation and strain is minimal. Finally, residual stresses due to cold bending calculated from the numerical analysis were assessed and a revised stress value for the service load design of the curved girder is proposed.

On the Interference of Ultra Wide Band Systems on Point to Point Links and Fixed Wireless Access Systems

  • Giuliano, Romeo;Guidoni, Gianluca;Mazzenga, Franco
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.163-172
    • /
    • 2004
  • Ultra Wide Bandwidth (UWB) spread-spectrum techniques will playa key role in short range wireless connectivity supporting high bit rates availability and low power consumption. UWB can be used in the design of wireless local and personal area networks providing advanced integrated multimedia services to nomadic users within hot-spot areas. Thus the assessment of the possible interference caused by UWB devices on already existing narrowband and wideband systems is fundamental to ensure nonconflicting coexistence and, therefore, to guarantee acceptance of UWB technology worldwide. In this paper, we study the coexistence issues between an indoor UWB-based system (hot-spot) and outdoor point to point (PP) links and Fixed Wireless Access (FWA) systems operating in the 3.5 - 5.0 GHz frequency range. We consider a realistic UWB master/slave system architecture and we show through computer simulation, that in all practical cases UWB system can coexist with PP and FWA without causing any dangerous interference.

A Study on the Effect of Hot Lines and the Assembly of Flange for a Refrigerator to Reduce Dew Generation (냉장고 Flange부 이슬 맺힘 방지를 위한 열선의 영향 및 조립에 관한 연구)

  • Kim, Na Hyun;Cho, Jong Rae;Park, Sang Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • When the temperature of a flange in a refrigerator is reduced to the dew point, condensation is generated on the flange. Generally, hot lines, having a temperature of $35^{\circ}C$, are located near the flange to increase its surface temperature above the dew point. Hot lines are installed in close contact with the flange in order to increase the heat transfer from the hot lines to the flange surface. Through this work, the effects of the hot line shape and installation conditions, including a gap between the hot line and flange, and the function of a spacer in the inner case of the refrigerator were investigated. Additionally, an optimal shape of the inner case for easy assembling is proposed considering the contact between the hot line and flange.

Railway Switching Point Heating System Using the Photovoltaic-Wind Power Hybrid (태양광-풍력 하이브리드를 이용한 철도 선로전환기 융설 장치 구현)

  • Kim, Dae-Nyeon;Park, Han-Eol;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • This paper proposes the method to implement the railroad switching point heating system using the hybrid of the photovoltaic and wind power. The goal of the implementation of the railroad switching point heating system is to prevent freezing of the snow in the winter. The heating system of railway used to supply electricity through photovoltaic and wind power to prevent freezing. Hot wires of the railroad switching point heating system are used about 2kW of electric energy at the day. The electric energy of 2kW used the length of the hot wires about 3m. As the ON and/or OFF mode considering the tracks temperature and the ambient temperature, so the way the use of power-saving effect. In addition, the system can be used the railroad switching point heating system in winter and railway signal and street lights around the track in summer. In experiment, we acquired the power data according to time at the day of photovoltaic and wind power. We confirmed the temperature rise using the heating cable for 3m of $85^{\circ}C$, 30W/m. The temperature rise of the heating cable changes the temperature of $5^{\circ}C$ after 10 minutes and $11^{\circ}C$ after 10 minutes. We have confirmed the possibility of the railroad switching point heating system using the hybrid of the photovoltaic and wind power.

  • PDF

Actual Energy Consumption Analysis on Temperature Control Strategies (Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control) of Secondary Side Hot Water of District Heating System (지역난방 2차측 공급수 온도 제어방안(설정온도 제어, 외기온 보상제어, 외기온 예측제어)에 따른 에너지사용량 실증 비교)

  • Cho, Sung-Hwan;Hong, Seong-Ki;Lee, Sang-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.137-145
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side of District Heating System (DHS) with different hot water supply temperature control methods are compared. Three methods are Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Prediction Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side of the system, the results show that Outdoor Temperature Prediction Control method saves more energy. In general, Outdoor Temperature Prediction Control method lowers the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, Outdoor Temperature Prediction Control method saves about 7.1% in comparison to Outdoor Temperature Reset Control method and about 15.7% in comparison to Set-point Control method. Also, it is found that at when partial load condition, such as daytime, the fluctuation of hot water supply temperature with Set-point Control is more severe than Outdoor Temperature Prediction Control. Therefore, it proves that Outdoor Temperature Prediction Control is more stable even at the partial load conditions.