• 제목/요약/키워드: hot air heating

검색결과 332건 처리시간 0.026초

수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구 (Studies on Performance of CO2 Water Heater by Numerical Modeling)

  • 박한빛;윤린
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation (Simulation of the hot water ONDOL heating system by response factor method)

  • 조상준;민만기;최영돈
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.409-424
    • /
    • 1987
  • 본 연구에서는 유한차분법보다는 정확도가 약간 떨어지지만 공기조화 분야의 계산에 적합하고 계산시간이 적게 소요되는 응답계수법을 사용하여 온수온돌방계의 비 정상 열전달을 해석하였다.

소형 황토 찜질방의 온수유량 변화에 대한 온도분포 특성 (Temperature Distribution Characteristics for Changes in Hot Water Flow in A Small Ocher Jjimjilbang)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제19권7호
    • /
    • pp.74-80
    • /
    • 2020
  • The ocher jjimjilbang for a single-person household that will be studied in this study is 2.1 ㎡ in size, and this study was conducted to implement well-being room heating that is beneficial to health by supplying radiant heat provided by hot water during room heating by embedding hot water panels in the walls of the ocher jjimjilbang to configure a hot water circulating system. In addition, the ocher bed and the ocher walls, which have been verified through many study findings and reference materials, were constructed so that the living life with a bed and the ocher jjimjilbang would be implemented simultaneously. As the mass flow rate of the hot water increased, the magnitude of the wall temperature rise thanks to the hot water increased, and as the flow rate of the hot water increased, the transfer rate of the heat transferred from the wall of the ocher jjimjilbang to the air inside the wall of the ocher jjimjilbang increased.

가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰 (A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System)

  • 유원주;이승현
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.81-95
    • /
    • 2010
  • Gas turbines generating power operate in high temperature condition and use natural gas as fuel. For that reason, there are many cases where damage is done to the hot gas parts caused by the high temperature and many accidents occur like gas explosions, then various efforts are needed to maintain the hot gas parts and prevent accidents. It is difficult to find the root causes of damage to the hot gas parts from the gas explosion caused by gas leakage through rotor cooling air line from fuel gas heat exchanger during the shut down. To prevent gas turbine from damage, removal of gas leakage inside of gas turbine is required by purging the turbine before firing, improving the fuel gas heating system and installing alarm systems for detecting gas leakage from stop valve to turbine while the gas turbine has shut down.

  • PDF

가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰 (A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System)

  • 유원주;이승현
    • 대한안전경영과학회지
    • /
    • 제12권2호
    • /
    • pp.75-82
    • /
    • 2010
  • Gas turbines for power generating operate in a very high temperature condition and use natural gas for fuel. For this reason, many cases of damage happen at hot gas parts which are severely affected by high temperature gas and many cases of explosion occur by fuel gas. So a lot of efforts should be made to prevent hot gas parts damage and gas explosion accidents. Though there are many damage cases and explosion accidents, it is very difficult to find out the root causes of hot gas parts damage caused by gas explosion due to gas leakage in the heat exchanger for air cooling and gas heating. To prevent gas turbine from damage caused by gas explosion, removal of leakage gas from gas turbine is inevitably required before firing the gas turbine and installing alarm systems is also required for detecting gas leakage at stop valve to turbine while shut down.

중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구 (A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF

전기발열시트 표면가열 양생공법의 현장적용 연구 (An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

상-파넬 히-팅의 해석법 (Steady and Transient Solution of heat Conduction from hurried Pipes of panel heating Slab)

  • 이건
    • 대한설비공학회지:설비저널
    • /
    • 제3권3호
    • /
    • pp.185-190
    • /
    • 1974
  • Floor panel heating system is popular in Korea as dwelling house heating system. There are two methods for keeping floor surface warm. One method is delivering warm air under the floor such as Roman Hypocaust and Korean traditional Ondol. The other method is imbedding hot water pipes into the concrete floor slab. This paper gives basic equations for steady and transient solutions of heat conduction from hurried pipes. For steady-state solution, fin Efficiency Method and Sink and Source Method were introduced. Sink and Source Method is applied to transient state and basic solution is given in the form of Exponential Integral Function. Numerical solutions can be solved easily by digital computer from these equations.

  • PDF

심야전력 전기히터, 온풍난방을 채용한 단동 하우스의 열부하 해석 및 난방효율 평가 (Evaluation of Heating Efficiency and Analysis of Heating Loads in Greenhouses with Heating Systems of Electric Power Midnight or Hot Air)

  • 최동호;허종철;임종환;서효덕
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 정기총회 및 학술논문발표요지
    • /
    • pp.5-8
    • /
    • 1999
  • 동일부지내에 설치된 각 단동하우스에 무가온 상태 및 심야전력 전기히터, 온풍난방기를 각각 설치하여, 동절기 시설원예용 하우스의 온열환경, 난방방식별 에너지 소비특성, 난방효율에 대해서 검토하였다. 동절기 하우스의 벽체, 지붕을 통해 유출되는 관류열량을 정량적으로 계산하므로서, 하우스의 단열계획과 효율적 난방방식의 선정 및 난방에너지 절약을 유도할 수 있는 기초데이터를 제시하고자 한다. (중략)

  • PDF

THE EFFECT OF HEAT TREATMENTS ON THE CHLOROPHYLL IN GREEN PEPPER

  • Lee, Kap-Lang;Park, Jyung-Rewng;Lee, Sung-Woo
    • 한국식품영양과학회지
    • /
    • 제3권1호
    • /
    • pp.13-16
    • /
    • 1974
  • Chlorophyll을 함유(含有)하고 있는 녹색 식물(植物)의 조리(調理)에 의(依)한 색깔 변화(變化)는 대단히 중요(重要)하므로, 본실험(本實驗)은 각각(各各) 다른 열처리(熱處理)와 시간(時間)이 풋고추의 chlorophyll 함량(含量)에 미치는 영향을 조사하였다. 풋고추는 boiling water steam 그리고 hot air 를 사용(使用)하여, $100^{\circ}C$에서 5 10 15 분간(分間) 가열(加熱)했고, microwave oven에서는 1 2 3 분간(分間) 처리했다. 결과(結果)에 의(依)하면 chlorophyll 함량(含量)은 일반적(一般的)으로 가열시간(加熱時間)이 길어짐에 따라 감소하는 경향이었으며, 가열처리중(加熱處理中) steam이 가장 큰 영향을 주었고, boiling water 가 그 다음이었다. Hot air와 microwave 처리한 풋고추는 아주 적은 양의 chlorophyll이 변화(變化)하였다. 일반적으로 pheophytin 생성(生成) chlorophyll 함량(含量)이 감소함에 따라 증가(增加)하였다.

  • PDF