• Title/Summary/Keyword: horizontal valve

Search Result 36, Processing Time 0.026 seconds

Mini-Bentall Surgery: The Right Thoracotomy Approach

  • Jawarkar, Manish;Manek, Pratik;Wadhawa, Vivek;Doshi, Chirag
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.554-557
    • /
    • 2021
  • Surgeons are increasingly using the right mini-thoracotomy approach to perform aortic valve surgery. This approach has shown better results in terms of blood loss and length of hospital stay than the sternotomy approach. For selected patients requiring aortic root and ascending aorta surgery, a right mini-thoracotomy approach may prove beneficial. In our technique, we placed a 5-cm horizontal skin incision in the right second intercostal space. Femoro-femoral cardiopulmonary bypass was established. A valved aortic conduit was used for aortic root replacement. The patient's postoperative course was uneventful, with a short hospital stay. This technique offers a minimally invasive approach to aortic root and ascending aorta surgery with easy adaptability and reduced costs.

A development of value protection cover as safty device in running water pipe ($\cdot$하수도관의 밸브 개폐통의 안전장치 개발)

  • 허성관;임승환;최종탁
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.267-270
    • /
    • 1998
  • Current valve protection cover had problem that the hight of cover cap and road level could not match when the road was repaired and overcovered. But new developed device can solve this problem by forming several grooves in the connecting pipe. This device is devided into col=netting pipe (down side) and cap part.(upper side) On the outside diameter of connecting pipe, several horizontal grooves and two vertical grooves are formed. Through the horizontal grooves, the hight of cap part ran be adjusted with ground level. Therefore, this device can help easy maintenence in running water pipe.

  • PDF

Thermal Cycling Screening Criteria to RCS Branch Lines in Domestic Nuclear Power Plant (국내 원전 RCS 분기배관에 대한 열피로 선정기준)

  • Park, Jeong Soon;Choi, Young Hwan;Lim, Kuk Hee;Kim, Sun Hye
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.54-60
    • /
    • 2010
  • Piping failures due to thermal fatigue have been widely reported in normally stagnant non-isolable reactor coolant branch lines. Since the thermal fatigue due to thermal stratification was not considered in the piping fatigue design in old NPPs, it is important to evaluate the effect of thermal stratification on the integrity of branch lines. In this study, geometrical screening criteria for Up-horizontal branch lines in MRP-132 were applied to SI(Safety Injection) lines of KSNP 2-loop and WH 3-loop. Some computational fluid dynamic(CFD) analyses on the Reactor Coolant System(RCS) branch lines were also performed to develop the regulatory guidelines for screening criteria. As a result of applying MRP-132 screening criteria, KSNP 2-loop and WH 3-loop SI lines are determined to need further detailed evaluation. Results of CFD analyses show that both valve isolation and amount of leakage through valve can be used as technical bases for the screening criteria on the thermal fatigue analysis.

  • PDF

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline (상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석)

  • Lee, Hohyun;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.834-840
    • /
    • 2021
  • The management and installation methods of pressure gauges in water supply pipeline are not efficiently regulated and their installations are different in each site. In this paper, various domestic and overseas documents are examined about the pressure gauge. In order to improve the efficiency of operation management such as pipeline network and pump operation, water pressure needs to be measured as accurate as possible, by which decision making for optimal pipe network can be achieved. To get the goal, the installation of pressure gauge should be reviewed about where and how to install. In this study, an optimal horizontal distance test is conducted, in which pressure value variation is monitored and analyzed according to up and down stream distances and valve flow control, and a optimal vertical position test is also analyzed by installing the pressure gauges vertically from the up(180°) to the bottom (0°) of the pipeline.

A comparative study of the morphology of the ovipositors of wood-boring insects, Tremex fuscicornis and Leucospis japonica (목질을 천공하는 얼룩송곳벌(Tremex fuscicornis)과 밑드리좀벌(Leucospis japonica) 산란관의 형태적 특징 비교)

  • Kim, Ji Yeong;Park, Ji-Hyun;Kwon, Oh Chang;Kim, Jinhee
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.4
    • /
    • pp.554-562
    • /
    • 2020
  • Tremex fuscicornis (Siricidae), known as the xylophagous horntail, and Leucospis japonica (Leucospidae), known as the parasitoid wasp, are wood-boring wasps belonging to the order Hymenoptera. These insects are interesting sources of biological inspiration for the development of drilling mechanisms. To study the biomimicry aspects, the morphological characters of the ovipositor of T. fuscicornis and L. japonica were analyzed using a stereoscopic microscope, a field emission scanning electron microscope, and an optical microscope. There were many differences in the ovipositors between the two species, such as shape, length, surface structure, and arrangement of the teeth. Evenly arranged teeth were developed at the tip of both the dorsal valve and the ventral valve of the ovipositor of T. fuscicornis and looked like a rotating drill bit. In contrast, in L. japonica, the teeth, which looked like a saw, were found only on the ventral valve. Moreover, the tip of the ovipositor of T. fuscicornis was symmetrically divided into four parts, while that of L. japonica was divided into three parts having a 2:1:1 ratio. However, in the case of T. fuscicornis, after the 14th tooth, four parts melded into three parts maintaining a 2:1:1 ratio, and a dovetail joint was found on the horizontal cross-section of the ovipositor that allowed vertical movement for making a hole. These morphological differences of the ovipositor may be due to the insects' lifestyles and phylogenetic distance. Finally, zinc was commonly found at the tip of the ovipositors of both species, a probable result of ecological adaptation created by drilling wood.

Study on the Damping Mechanism of an Hydraulic Type Automotive Seat Damper (자동차용 유압식 시트댐퍼의 댐핑 메카니즘에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 2016
  • Typically, the seat of an automotive vehicle generally includes a horizontal seat-cushion portion and a vertical seat-back portion that is operatively connected to the seat-cushion portion. The seat may include a recliner for the reclining of the seat-back portion relative to the seat-cushion portion by the seat occupant. An energy absorber or damper can also be provided for the seat-back portion. Because the recliner is configured to be released at a relatively high speed, and it results in an impact at the end of a folding stroke, the damper needs to dissipate energy as the seat back moves with respect to the seat cushion; therefore, the role of the seat damper in the automotive-seat design is important. In this paper, the mechanism of an hydraulic-type automotive-seat damper is investigated, and the torque characteristic is simulated according to the design-parameter variations such as the orifice area and the working-fluid properties.

Ebstein`S Anomaly: A Case Report of Plication and Tricuspid Valve Replacement (Ebstein 심기형 수술 1례[Plication 및 삼첨판막 이식예])

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.342-347
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF