• 제목/요약/키워드: horizontal reference plane

검색결과 63건 처리시간 0.024초

Hair Diameter Variation in Different Vertical Regions of the Occipital Safe Donor Area

  • Yun, Seon Sik;Park, Jae Hyun;Na, Young Cheon
    • Archives of Plastic Surgery
    • /
    • 제44권4호
    • /
    • pp.332-336
    • /
    • 2017
  • Background Little is known concerning hair diameter variation within the safe donor area for hair transplantation surgery. Thicker or thinner hair may be needed, depending on the recipient area, hairline design, and the purpose of surgery. Methods Twenty-seven patients (7 men and 20 women; mean age, 28 years; range, 20-47 years) were included in this study. The midoccipital point was used as the reference point on the horizontal plane at the upper border of the helical rim. The target area width was 15 cm (7.5 cm to the right and left of the reference point) and the height was 8 cm (2 cm above and 6 cm below the reference point). The study area was divided horizontally into 3 5-cm sections (A, B, C) and vertically into 4 2-cm sections (1-4), creating a total of 12 zones. Ten anagen hairs were randomly obtained from each zone and their diameters were measured. Results Hair diameter in the 4 vertical sections varied significantly, gradually decreasing from sections 1 (superior) to 4 (inferior) in all 3 horizontal sections (A, B, and C). Conclusions Our results suggest that sections 1 and 2 of the occipital safe donor area would be useful for obtaining thicker hair, such as in procedures to treat male- and female-pattern hair loss, whereas hair from zones 3 and 4 could be useful for transplantation surgery requiring thinner hair, such as eyebrows, eyelashes, and female hairline correction. Our results may be clinically valuable for planning hair transplant surgery and choosing the optimal donor region.

Usefulness of lateral cephalometric radiography for successful blind nasal intubation: a prospective study

  • Ito, Kana;Kamura, Ayaka;Koshika, Kyotaro;Handa, Toshiyuki;Matsuura, Nobuyuki;Ichinohe, Tatsuya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권6호
    • /
    • pp.427-435
    • /
    • 2022
  • Background: This study aimed to investigate the relationship between pharyngeal morphology and the success or failure of blind nasotracheal intubation using standard lateral cephalometric radiography and to analyze the measurement items affecting the difficulty of blind nasotracheal intubation. Methods: Assuming a line perpendicular to the Frankfort horizontal (FH) plane, the reference point (O) was selected 1 cm above the posterior-most end of the hard palate. A line passing through the reference point and parallel to the FH plane is defined as the X-axis, and a line passing through the reference point and perpendicular to the X-axis is defined as the Y-axis. The shortest length between the tip of the uvula and posterior pharyngeal wall (AW), shortest length between the base of the tongue and posterior pharyngeal wall (BW), and width of the glottis (CW) were measured. The midpoints of the lines representing each width are defined as points A, B, and C, and the X and Y coordinates of each point are obtained (AX, BX, CX, AY, BY, and CY). For each measurement, a t-test was performed to compare the tracheal intubation success and failure groups. A binomial logistic regression analysis was performed using clinically relevant items. Results: The items significantly affecting the success rate of blind nasotracheal intubation included the difference in X coordinates at points A and C (Odds ratio, 0.714; P-value, 0.024) and the ∠ABC (Odds ratio, 1.178; P-value, 0.016). Conclusion: Using binomial logistic regression analysis, we observed statistically significant differences in AX-CX and ∠ABC between the success group and the failure group.

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

  • Jin, Ming-Xu;Hong, Min-Ho;Lee, Kee-Joon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.125-130
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS. In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of $0^{\circ}$. The device was rotated to $10^{\circ}$ in $1^{\circ}$ increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS. From $1^{\circ}$ to $10^{\circ}$, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at $0^{\circ}$. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION. Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from $1^{\circ}$ to $10^{\circ}$ during frontal photography does not affect these ratios.

Digora$\textregistered$에서 정량영상의 특성에 대한 평가 (The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$)

  • 김재덕
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

태양광 패널 일사량에 기반한 대표연도 데이터 비교 평가 (Comparative Assessment of Typical Year Dataset based on POA Irradiance)

  • 윤창열;김보영;김창기;김현구;강용혁;김용일
    • 신재생에너지
    • /
    • 제20권1호
    • /
    • pp.102-109
    • /
    • 2024
  • The Typical Meteorological Year (TMY) dataset compiles 12 months of data that best represent long-term climate patterns, focusing on global horizontal irradiance and other weather-related variables. However, the irradiance measured on the plane of the array (POA) shows certain distinct distribution characteristics compared with the irradiance in the TMY dataset, and this may introduce some biases. Our research recalculated POA irradiance using both the Isotropic and DIRINT models, generating an updated dataset that was tailored to POA characteristics. Our analysis showed a 28% change in the selection of typical meteorological months, an 8% increase in average irradiance, and a 40% reduction in the range of irradiance values, thus indicating a significant shift in irradiance distribution patterns. This research aims to inform stakeholders about accurate use of TMY datasets in potential decision-making. These findings underscore the necessity of creating a typical dataset by using the time series of POA irradiance, which represents the orientation in which PV panels will be deployed.

한국아동의 악안면성장에 관한 유한요소법적 연구 (A STUDY ON CRANIOFACIAL GROWTH ANALYSIS OF KOREAN CHILDREN BY THE FINITE ELEMENT METHOD)

  • 탁선근
    • 대한치과교정학회지
    • /
    • 제18권2호
    • /
    • pp.343-366
    • /
    • 1988
  • Craniofacial complex is influenced by numerical skeletal elements. Though the analysis of growth change has been done by various analytical methods, it was dependent on any method of registration and superimposition, based on reference plane and reference point. However, the craniofacial growth is composed of a number of local growth elements. Therefore, it will be necessary to use a clinically useful method for estimating craniofacial skeletal growth independently. The author analysed longitudinal cephalometric roentgenogram of 15 Korean males and 15 Korean females aged from 6 to 12 years by the finite element method and results were as follows : 1. The finite element method for craniofacial skeletal complex and soft tissue made it possible to analyze the independent local growth. 2. Regression equations from the value of each strain will make it possible to predict the craniofacial growth. 3. The growth of anterior cranial base was different from that of other facial bone. 4. The growth of posterior cranial base influenced the growth of upper pharyngeal region, midfacial region, maxilla and posterior region of mandible. 5. The growth of maxillary complex was vertical rather than horizontal. 6. The growth direction of ramus, mandibular body, alveolar bone was various. 7. The relation between hard tissue and soft tissue by finite element method was variant.

  • PDF

X선상 형성과정에서 위치측정에 관하여 (LOCALIZATION TO THE PRODUCTION OF RADIOGRAPHIC IMAGE)

  • 박태원
    • 치과방사선
    • /
    • 제11권1호
    • /
    • pp.75-78
    • /
    • 1981
  • The diagnostic value of a intra oral film is related to projecting technic and interpretation. The intra-oral film is a single plane representation of a three dimensional object, therefore superimposition is inevitablly present. The purpose of this article is to show how foreign objects in the jaw may be localized. The author used double exposure technics, that are changed angulation of vertical or horizontal to one film. The obtained results are as fallow: 1. In the upper anterior region, the moving distance of the labially impacted reference object was greater than that of the palatally impacted one. 2. In the upper molar region, the moving distance of the mesiobuccal root apex was the greatest and that of palatal root apex was the shortest. 3. In the lower molar region, the change of the alveolar bone level in the buccal side was greater than that of lingual side.

  • PDF

부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례 (Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring)

  • 우정웅;이준기;강태섭
    • 지구물리와물리탐사
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2016
  • 셰일가스 개발 과정에서 수압 파쇄에 의해 발생하는 미소지진의 진원 분포는 균열대의 특성을 파악하는 데 필요한 중요한 정보를 제공한다. 본 연구에서는 가상의 진원에 대하여 부정확한 속도 구조 모델이 선형 역산법을 이용한 진원 결정 프로그램인 hypoellipse와 hypoDD의 결과에 어떠한 영향을 미치는 지에 대해서 알아보았다. 총 98개의 가상 관측소를 반경 4 km의 원내에 배치하였고, 25개의 지진들이 판상으로 분포한 가상 지진 세트를 관측망의 중심부에서부터 남쪽으로 1 km 간격으로 5곳에 배치하였다(S0 ~ S4). 역산 결과의 정확성을 정량적으로 평가하기 위해 진원들의 평균 위치의 차이를 의미하는 $d_1$, 가정한 진원에 대한 면적비 r, 근사 평면과 실제 평면의 경사 차이 ${\theta}$, 근사 평면과 실제 평면의 주향 차이 ${\phi}$, 근사 평면으로부터 진원들이 떨어진 거리의 제곱평균제곱근 $d_2$, 평면상에서의 진원들의 패턴의 정확성 $d_3$의 6가지 파라미터를 정의하였다. 층상 구조를 가정한 기준 속도 구조를 만들어 합성 주시자료를 계산하였으며, 속도 구조의 부정확성을 고려하기 위하여 진원 역산에 사용한 속도 구조 모델은 각 층의 기준 속도를 중심으로 0.1 km/s, 0.2 km/s, 및 0.3 km/s의 표준편차를 가지는 정규분포를 이용하여 구성하였다. 속도의 부정확성에 비례하여 오차가 커지는 파라미터에는 $d_1$, r, ${\theta}$, 및 $d_3$가 있으며, 나머지 두 파라미터는 S4의 경우를 제외하면 속도 부정확성의 정도와 관계없이 일정한 오차를 보여준다. S0, S1, S2, S3의 경우, hypoellipse와 hypoDD 모두 비슷한 $d_1$ 값을 나타낸다. 하지만 다른 파라미터의 경우 hypoDD가 훨씬 나은 결과를 보여주며, 진원의 상대적 오차는 속도 구조의 부정확도와 관계없이 수 미터 이하이다. 수압 파쇄의 부피 양상을 알기 위한 목적으로 상대적 진원 위치 부정확성을 수 미터 이내로 제한시키기 위해서 hypoellipse에서는 0.2 km/s 이내의 속도 오차의 표준편차를 가져야하며, hypoDD에서는 속도 오차의 표준편차 값이 0.3 km/s일 때에도 상대적 진원 위치 오차를 수 미터 이내로 제한시킬 수 있다.

Comparison of the effects of rapid maxillary expansion and alternate rapid maxillary expansion and constriction protocols followed by facemask therapy

  • Ozbilen, Elvan Onem;Yilmaz, Hanife Nuray;Kucukkeles, Nazan
    • 대한치과교정학회지
    • /
    • 제49권1호
    • /
    • pp.49-58
    • /
    • 2019
  • Objective: The aim of this retrospective study was to evaluate and compare the changes in the pharyngeal airway (PA), maxillary sinus volume, and skeletal parameters after rapid maxillary expansion (RME) and alternate rapid maxillary expansion and constriction (Alt-RAMEC) followed by facemask (FM) therapy. Methods: The records of 40 patients with skeletal Class III malocclusion due to maxillary retrognathism were collected, and the patients were assigned into two groups. The first group comprised 8 male and 12 female patients (mean age, $10.0{\pm}1.1years$) treated using RME/FM for an average of 10 months. The second group comprised 10 male and 10 female patients (mean age, $9.64{\pm}1.3years$) treated using Alt-RAMEC/FM for an average of 12 months. Cone-beam computed tomography images acquired before (T0) and after treatment (T1) were evaluated. Results: Regarding the skeletal effects, significant differences between the groups were the increase in ANS-HRP (perpendicular distance of ANS to the horizontal reference plane, 0.99 mm, p <0.05) in the Alt-RAMEC/FM group and the decrease in PP-SN (palatal plane to Sella-Nasion plane, $0.93^{\circ}$, p < 0.05) in the RME/FM group. Maxillary sinus volumes increased significantly in both the groups, and the increase was statistically significantly higher in the Alt-RAMEC/FM group. Although no significant intergroup differences were observed in PA volumes, both lower ($1,011.19mm^3$) and total ($1,601.21mm^3$), PA volume increased significantly in the Alt-RAMEC/FM group. Conclusions: The different expansion devices and protocols used with FM therapy do not seem to affect the forward movement of the maxilla and PA volumes. In contrast, the increase in maxillary sinus volume was greater in the Alt-RAMEC/FM protocol.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.