Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load (정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구)

  • Song, Jung-Hyeon;Kim, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

Fatigue Characteristics of Bicycle Frames Depending on Types and Materials (자전거 프레임의 소재 및 종류에 따른 피로특성)

  • Kwon, Kyoung-Bae;Cheong, Seong Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.8-12
    • /
    • 2017
  • Bicycles are very popular sporting goods in these days. Thus, the durability of bicycles is very important for the safety of bicyclists. It is well known that a bicycle frame is a major component which is essential to the safety and performance of a complete bicycle. In this study, the durability of bicycle frames were experimentally investigated under the fatigue load. Eighty bicycle frames with different types and materials were prepared and tested according to EN standards. Three kinds of fatigue loads, that is, pedalling, vertical and horizontal fatigue load, which occur constantly during riding a bicycle, were applied to the bicycle frames. The experimental results show that the horizontal fatigue load was the severest mode to pass EN standard. The pass ratio of horizontal fatigue load test was 45.2%, while the pass ratio of vertical fatigue load test was 100%. Most of cracks were found at the right side of bottom bracket shell and at the intersection area between head tube and down tube. It seems that the experimental results can be applied to improve the safety and performance of a bicycle frame.

Evaluation of Applicability of Sliding Carriage on the Membrane Retractable Roof under Vertical and Horizontal Load Considering the Inner Holder with Various Section Characteristics (다양한 단면성질의 Inner Holder를 고려한 연성 개폐식 Sliding Carriage의 수직 및 수평하중에 대한 적용성 평가)

  • Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • Middle size of membrane retractable roof is under 25m span which consists of various moving systems. Sliding carriage is the system that leads the membrane to parking place, transferring the load from the membrane to structural cable. When membrane moves roof, thus, structural behavior of sliding carriage, which may contain various shapes with friction coefficients, should be investigated by vertical load as well as horizontal load. Nummerical simulation of sliding carriage prototypes, in this research, were performed by incrementation of vertical load and horizontal load as well. Consequently, this paper evaluated proper shapes of inner holder of Sliding carriage and evaluated the effective contact area of inner hold.

Behavioral Analysis of Triaxial Micropile (TMP) through Field Loading Test and 3D-numerical Analysis (삼축 마이크로파일(TMP)의 현장수평재하시험과 3차원 수치해석을 통한 거동 분석)

  • Kim, Taehyun;Ahn, Kwangkuk;An, Sungyul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.4
    • /
    • pp.15-23
    • /
    • 2021
  • Various micropiles have been developed through research related to micropiles, which have been carried out with the increased use of micropiles. Among the micropile construction methods being developed, the triaxial micropile (tmp), which is recently developed for the purpose of increasing the horizontal bearing capacity (seismic resistance), is representative. The three-axis micropile has the advantage of a method that can resist horizontal load more effectively because three micropiles installed inclined on each axis resist horizontal load. However, there is a problem in effectively using this pile method due to insufficient research on the support characteristics of the triaxial group micropile. In order to effectively utilize the triaxial group micropile (tmp), it is required to evaluate the bearing capacity for the factors that affect the horizontal bearing capacity of the pile. Therefore, in this study, field horizontal loading Tests were performed for each load direction, field loading Tests were verified through three-dimensional finite element analysis, behavioral characteristics of triaxial micropiles were evaluated, and appropriate horizontal bearing capacity was analyzed in consideration of horizontal load directions.

Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand (세립 사질토 지반에 설치된 석션 앵커의 수평 지지력)

  • Kim, Surin;Choo, Yun Wook;Kim, Dong-Soo;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2013
  • A suction anchor is one of the most popular anchors for deepsea floating systems. An anchor used for catenary mooring is predominantly under a horizontal load. In this study, the behavior of a suction anchor installed in cohesionless soil was investigated when the anchor was mainly subjected to a horizontal load induced by a catenary line. In order to study the behavior of the suction anchor, 3D FEM analysis models were developed and analyzed. Depending on the location of the load (padeye), the ultimate horizontal load was monitored. The distributions of the reaction forces around the anchor induced by the seabed were analyzed using the circumferential stress to understand the behavior of the suction anchor under a horizontal load.

An Experimental Study and Numerical Analysis on Load Transfer Characteristics of Drilled Shafts (현장타설말뚝의 하중전이 특성에 대한 실험 및 해석적 연구)

  • Eonsang Park;Seungdo Park
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.5-14
    • /
    • 2023
  • In this study, the load transfer characteristics of the base and skin of drilled shafts were analyzed and the load sharing ratio was calculated by performing a load transfer large-scale model test and three-dimensional numerical analysis considering the similarity of drilled shafts, which is the design target. From the linear behavior of drilled shafts shown in the large-scale model test and 3D numerical analysis results, the skin load transition curve for the design conditions of this study was proposed by Baquelin et al., and the base load transition curve was proposed by Baquelin et al. For the horizontal load transition curve, the formula proposed by Reese et al. was confirmed to be appropriate. The test value was slightly larger than the numerical analysis value for the axial load at the rock socketing, but the load sharing ratio at the rock socketing increased, on average, about 27.8% as the vertical load increased. The analysis value of the vertical settlement of the pile head under the vertical load was evaluated to be slightly smaller than the test value, and the maximum vertical settlement of the pile head in the model test and analysis maximum vertical load was 10.6 mm in the test value and 10.0 mm in the analysis value, and the maximum vertical settlement value at the base of the pile was found to be a test value of 2.0 mm and an analysis value of 1.9 mm. The horizontal displacement at the head of the column (ground surface) and the head of the pile during the horizontal load was found to agree relatively well with the test value and the analysis value. As a result of the model soil test, the horizontal load measured at the maximum horizontal displacement of 38.0 mm was evaluated to be 24,713 kN, and the horizontal load in the numerical analysis was evaluated to be 26,073 kN.

Behavior of eccentrically inclined loaded footing resting on fiber reinforced soil

  • Kaur, Arshdeep;Kumar, Arvind
    • Geomechanics and Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-174
    • /
    • 2016
  • A total of 104 laboratory model tests on a square footing subjected to eccentrically inclined loads supported by sand reinforced with randomly distributed polypropylene fibers were conducted in order to compare the results with those obtained from unreinforced sand and with each other. For conducting the model tests, uniform sand was compacted in a test box at one particular relative density of compaction. The effect of percentage of reinforcement used, thickness of the reinforced layer, angle of inclination of load to vertical and eccentricity of load applied on various prominent factors such as ultimate load, vertical settlement, horizontal deformation and tilt were investigated. An improvement in ultimate load, vertical settlement, horizontal deformation and tilt of foundation was observed with an increase in the percentage of fibers used and thickness of reinforced sand layer under different inclinations and eccentricities of load. A statistical model using non-linear regression analysis based on present experimental data for predicting the vertical settlement ($s_p$), horizontal deformation ($hd_p$) and tilt ($t_p$) of square footing on reinforced sand at any load applied was done where the dependent variable was predicted settlement ($s_p$), horizontal deformation ($hd_p$) and tilt ($t_p$) respectively.

A Study on Design of Movable Horizontal Shading Device for Office Building (사무소건물의 가동식 수평차양에 대한 연구)

  • Kim, Mi-Hyun;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.50-57
    • /
    • 2008
  • This study intends to evaluate the effect on indoor environment(annual thermal load, sunshine)by the application of the movable horizontal shading device on summer and winter season. For these purpose, we supposed the models which are composed of the several horizontal shading devices. Then we analyzed the simulation using the IES5.5.1 and Seoul weather data. The results of this study are as follows: 1) The proper length, angle of horizontal shading device is 2.1m, 28 degree, respectively. 2) The decreasing rate of the annual load of the Movable Horizontal Shading Model(MHSM) in comparison with the No Shading Model(NSM) & Conventional Horizontal Shading Model(CHSM) is 31.11%, 6.63% respectively. 3) The decrease of sunshine of the MHSM on summer season is effective the alleviation of visual displeasure. On the other hand, the increase of sunshine of the MHSM on winter season is effective the psychological comfort. Further study is to be required the sensitivity analysis on the various shading length for the realistic proper shading length.

A Study on the Buckling Characteristics of Pipe Support(V6) (파이프서포트(V6)의 좌굴특성에 관한 연구)

  • Paik, Shin-Won;Song, In-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.59-62
    • /
    • 2011
  • Among the accidents and failures that occur during concrete construction, many are formwork failures which usually happen when concrete is being placed. A system of formwork filled with wet concrete has its weight at the top and is not basically a stable structure. Slab formwork consists of sheathing, stringer, hanger and shore. There are several types of adjustable shores. In construction site, pipe supports are usually used as a shore of slab formwork. In this study, pipe support systems with/without horizontal connector were measured by buckling test. Buckling load of respective pipe support system was analyzed by structural analysis program(MIDAS). Buckling load of pipe support with/without horizontal connector was got by test and structural analysis. According to these results, we know that horizontal connector made pipe support system very safe. Buckling load of pipe support with horizontal connector is 56% higher than that without horizontal connector. So horizontal connector is important in slab formwork systems. Finally, the present study results will be used to design slab formwork system safely in the construction sites.

Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle (면진장치 설치각도에 따른 아치구조물의 지진응답)

  • Kim, Gee-Cheol;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.