• Title/Summary/Keyword: horizontal load

Search Result 951, Processing Time 0.031 seconds

Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group (나선형 원형철근으로 보강된 집중배치 텐던 정착구역에 대한 하중전달시험)

  • Cho, Ah Sir;Kang, Thomas H.K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.59-67
    • /
    • 2017
  • In this study, load transfer tests based on KCI-PS101 were conducted to verify the performance of spiral anchorage zone reinforcement for banded post-tensioning (PT) monostrands. With results, the compressive strength of spiral reinforcement was increased by about 20% than that of specimens with two horizontal steel bars and 8% than that of U-shaped bars. Advanced spiral reinforcement for corner increases compressive strength and can resist the spalling forces or fall-out effect at the corner by shear. The ratio of maximum load to amount of steel of the spiral reinforcement is about twice than that of U-shaped reinforcement. With increase of compressive strength capacity and improvement of constructability, the spiral reinforcement is considered to have advantages of promoting the performance of PT anchorage zone compared to conventional methods.

Effect of rotation and inclined load on transversely isotropic magneto thermoelastic solid

  • Lata, Parveen;Kaur, Iqbal
    • Structural Engineering and Mechanics
    • /
    • v.70 no.2
    • /
    • pp.245-255
    • /
    • 2019
  • In present research, we have considered transversely isotropic magneto thermoelastic solid with two temperature and without energy dissipation due to inclined load. The mathematical model has been formulated using Lord-Shulman theory. The Laplace and Fourier transform techniques have been used to find the solution to the problem. The displacement components, stress components and conductive temperature distribution with the horizontal distance are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. The effect of rotation and angle of inclination of inclined load is depicted graphically on the resulting quantities.

Investigation on the failure type of tower segments under equivalent static wind loads

  • Li, Yue;Xie, Qiang;Yang, Zheng
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.161-171
    • /
    • 2022
  • This paper presents a failure type assessment curve method to judge the failure type of transmission tower segments. This novel method considers the equivalent static wind load characteristics and the transmission tower members' load-bearing capacities based on numerical simulations. This method can help judge the failure types according to the relative positions between the actual state points and the assessment curves of transmission tower segments. If the extended line of the actual state point intersects with the horizontal part's assessment curve, the segment would lose load-bearing capacity due to the diagonal members' failure. Another scenario occurs when the intersection point is in the oblique part, indicating that the broken main members have caused the tower segment to fail. The proposed method is verified by practical engineering case studies and static tests on the scaled tower segments.

Monotonic Loading Tests on Seismic Stiffeners for Vertical Hangers (수직 행거 내진설계용 스티프너의 단조 압축 실험)

  • Chang-Soo Oh;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.187-192
    • /
    • 2023
  • In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.

Cable sag-span ratio effect on the behavior of saddle membrane roofs under wind load

  • Hesham Zieneldin;Mohammed Heweity;Mohammed Abdelnabi;Ehab Hendy
    • Wind and Structures
    • /
    • v.36 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • Lightness and flexibility of membrane roofs make them very sensitive to any external load. One of the most important parameters that controls their behavior, especially under wind load is the sag/span ratio of edge cables. Based on the value of the pretension force in the edge cables and the horizontal projection of the actual area covered by the membrane, an optimized design range of cable sag/span ratios has been determined through carrying on several membrane form-finding analyses. Fully coupled fluid structure dynamic analyses of these membrane roofs are performed under wind load with several conditions using the CFD method. Through investigating the numerical results of these analyses, the behavior of membrane roofs with cables sag/span ratios selected from the previously determined optimized design range has been evaluated.

A Study on Field test of the Horizontal Ground Source Heat Pump for Greenhouse (시설원예용 수평형 지열히트펌프 시스템 실증연구)

  • Park, Yong-Jung;Kang, Shin-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.505-510
    • /
    • 2007
  • Greenhouses should be heated during nights and co Id days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger (GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF

Experimental Study on Drainage Characteristics of PET Aggregates (PET 인공골재의 배수특성에 관한 실험적 연구)

  • Shin, Eun-Chul;Shin, Hui-Su;Kim, Kyeong-Sig;Kim, Ki-Sung;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.35-44
    • /
    • 2016
  • PET aggregates were produced by mixing heated PET flakes with frictional soils. Using these artificially-made PET aggregates, horizontal drain tests in the laboratory, pilot scale model tests were conducted for the evaluation of the drainage characteristics of PET aggregates. Laboratory horizontal drain tests were conducted under twenty different conditions varying mixing ratios and surcharged pressures. Moreover, by utilizing the aggregates with a mixing ratio producing the lowest variation in terms of permeability against applied load, large scale tests were performed. Reliability of the test results was evaluated from comparison with the results of the laboratory horizontal drain test.

Analysis of Strength and Displacement of Jig Body in Index Machine (Index Machine의 Jig Body 강도 및 변위해석)

  • 한근조;오세욱;김광영;안성찬;전형용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.24-30
    • /
    • 1998
  • Strength and displacement of jig body in index machine utilized for multiprocess machining such as drilling, boring and tapping, etc, at the same time were analyzed by the use of finite element analysis soft ware ANSYS 5.2A. The whole geometry was constructed by 4048 elements and 7016 nodes employing 8 node brick element. The analyses were carried out on five loading cases combining vertical and horizontal machining to simulate the case occurring large displacement and the one occurring small displacement one and provided following conclusions. (1) Jig body had sufficient strength because its safety factor was 6.95 even in the most severe loading case. (2) The largest displacement in Z direction was 549 m and that in radial direction was 43.7 m. (3) In order to reduce the displacement, vertical machining rather than horizontal or two or three processes should be adopted in the same station. (4) Alternate change of horizontal machining direction at consecutive stations can reduce the displace ment. (5) The dimension of the slider should be increased to reduce the displacement by the tolerance in the sliding part. (6) A bypass idle piston head needs to be installed to give a counterpart supporting load from opposite direction for a single horizontal machining case.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Performance Analysis of the Horizontal Ground Source Heat Pump for Greenhouse (시설원예용 수평형 지열 히트펌프 시스템의 성능분석)

  • Park, Yong-Jung;Kang, Shin-Hyung
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.447-452
    • /
    • 2007
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger(GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump ($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF