• 제목/요약/키워드: horizontal electric field

검색결과 87건 처리시간 0.028초

Polarity Effects of Dielectric Anisotropy on Electro-Optical Characteristics of Fringe Field Twisted Nematic Mode

  • Shin, Sung-Sik;Jhun, Chul-Gyu;Kim, Woo-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.288-288
    • /
    • 2009
  • We have studied polarity effects of dielectric anisotropy effects on electro-optical characteristics of a twisted nematic mode driven by fringe electric field, which has wide viewing angle characteristics. Our device is designed as normally black mode between parallel polarizers. The perfect polarization conversion of incident light, which passes through a polarizer, is achieved, when it passes through the twisted liquid crystal (LC) layer. If an electric field is applied, the LC molecules with a positive (or negative) dielectric anisotropy rotate parallel (or perpendicular) to the horizontal component of a fringe electric field as increasing transmittance. From the calculated results, enhanced transmittance of the fringe field-twisted nematic (FF-TN) mode with positive dielectric anisotropy of + 8.2 can be obtained.

  • PDF

전장을 이용한 수평관 주위에서의 응축 열전달촉진에 관한 실험적 연구 (Experimental Study on the Enhancement of Condensation Heat Transfer on a Single Horizontal Tube Utilizing EHD)

  • 유갑종;추홍록;김석준;이성진
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3008-3020
    • /
    • 1994
  • Condensation heat transfer on a single horizontal tube with electric fields (Electro-Hydro-Dynamics, (EHD)) has been studied experimentally. Results are presented for EHD enhanced condensation of R-113 on a single horizontal tube using several electrode geometries. Especially, its attention was focused on the effects of electrode geometry, electric field strength and the gap of the electrode. In this study, single wire, helical, ring and mesh electrode were used. The range of the imposed voltage was 0~20 kV. As the voltage was increased the surface of liquid became an unstable wave, stream jet, liquid column and then liquid extraction in sequence. Among the various kinds of electrodes, the single wire electrode is suitable for practical application.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

Simulation of the Electrical Response of Charged Particles in the Fluid for Horizontal Switching Electrophoretic Cell

  • Yeo, Jun-Ho;Kim, Sang-Won;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.498-501
    • /
    • 2009
  • Electrophoretic displays (EPDs) are attracting considerable attentions as a paper-like display. Especially, Electrophoretic cell consists of micron-sized, charged particles dispersed in a viscous fluid. When an external electric field is applied, the charged particles move with a speed proportional to the particle mobility and the local field strength. In electrophoretic displays fast switching times are required, so knowing the particle mobility is very important. In this paper, we study a novel simulation for calculating the particle motions submerged in a viscous fluid for horizontal switching electrophoretic cell.

  • PDF

전기장으로 제어되는 ER유체의 유동특성에 관한 연구 (Study on Flow Characteristics of Electro-Rheological Fluids with Electric Field Control)

  • 윤신일;장성철;이해수
    • 한국공작기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.49-54
    • /
    • 2005
  • An experimental Investigation was performed to study the characteristics of Electro-Rheological fluid flow in a horizontal rectangular tube with or without D.C electric field control. First, the microscopic behavior of the ER suspension structure between rectangular tube brass electrodes for the stationary ER nut(i and flow of the ER fluid was investigated by flow visualization. The flow of the ER fluid between fluid rectangular tube was solved experimental using the constitutive equation for a Bingham fluid. ER fluid is made silicon oil mixed with $0.2wt\%$ starch having hydrous particles. Velocity distributions of the ER fluids were obtained by particle image velocimetry measuring those of the clusters using an image processing technique.

프린지 필드에 의해 구동되는 하이브리드형 네마틱 액정 셀에서 러빙방향에 따른 전기광학 특성 (Influence of Rubbing Direction on the Electro-Optic Characteristics of Fringe Field Driven Hybrid Aligned Nematic Liquid Crystal Cell)

  • 김완철;안명환;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제17권1호
    • /
    • pp.75-82
    • /
    • 2004
  • We have studied the influence of rubbing directions on electro-optic characteristics of the fringe field driven hybrid aligned nematic liquid crystal (LC) cell by computer simulation. When a LC with positive dielectric anisotropy is used, the results show that the driving voltage and transmittance decreases as the rubbing direction with respect to horizontal electric field direction increases. The reason for decrease in light transmission is the increase of tilt angle on the center of common electrode. In this paper, we have studied how the rubbing angle effects on the transmittance of the cell by investigating a distribution of electric field and LC director.

프린지 필드에 의해 구동되는 하이브리드형 네마틱 액정 셀에서 러빙방향에 따른 전기광학 특성 (Influence of Rubbing Direction on the Electro-Optic Characteristics of Fringe Field Driven Hybrid Aligned Nematic Liquid Crystal Cell)

  • 김완철;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.957-960
    • /
    • 2003
  • We have studied the influence of rubbing directions on electro-optic characteristics of the fringe field driven hybrid aligned nematic liquid crystal (LC) cell by computer simulation. When a LC with positive dielectric anisotropy is used, the results show that the driving voltage and transmittance decreases as the rubbing direction with respect to horizontal electric field direction increases. The reason for decrease in light transmission is the reduction of twist angle and increase of tilt angle on the center of common electrode. In this paper, we have studied how the rubbing angle effects on the transmittance of the cell by investigating a distribution of electric field and LC director.

  • PDF

송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석 (Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line)

  • 명성호;조연규;이동일;임윤석
    • 한국전자파학회논문지
    • /
    • 제17권11호
    • /
    • pp.1132-1142
    • /
    • 2006
  • 본 연구는 송전 선로 여러 가지 유형의 극저주파 자기장 저감 적용 모델을 조사하고 그 효과를 분석하였다. 본 연구에서는 154 kV 수평 배열 송전 선로를 기본으로 하여 적용 가능한 다양한 자기장 저감 모델에 대하여 적용시 얻게 되는 자기장 저감지수(Field Reduction Factor)를 검토하였다. 그 결과 compact 모델 채용시에는 상간거리 compact화 비율과 자기장 저감지수가 거의 비례하였으며, diamond 모델 및 transposed 선로 배치의 경우는 50 %에 근접한 자기장 저감이 가능하였다. 배전 선로에 적용이 가능한 삼각형 배열은 33 % 정도, 2회선 split는 50 % 정도 저감 효과가 나타나는 것으로 분석되었으며 수평 multi split 모델의 경우는 80 %까지 자기장 저감을 얻을 수 있었다.

Experimental Investigation of Physical Mechanism for Asymmetrical Degradation in Amorphous InGaZnO Thin-film Transistors under Simultaneous Gate and Drain Bias Stresses

  • Jeong, Chan-Yong;Kim, Hee-Joong;Lee, Jeong-Hwan;Kwon, Hyuck-In
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • We experimentally investigate the physical mechanism for asymmetrical degradation in amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs) under simultaneous gate and drain bias stresses. The transfer curves exhibit an asymmetrical negative shift after the application of gate-to-source ($V_{GS}$) and drain-to-source ($V_{DS}$) bias stresses of ($V_{GS}=24V$, $V_{DS}=15.9V$) and ($V_{GS}=22V$, $V_{DS}=20V$), but the asymmetrical degradation is more significant after the bias stress ($V_{GS}$, $V_{DS}$) of (22 V, 20 V) nevertheless the vertical electric field at the source is higher under the bias stress ($V_{GS}$, $V_{DS}$) of (24 V, 15.9 V) than (22 V, 20 V). By using the modified external load resistance method, we extract the source contact resistance ($R_S$) and the voltage drop at $R_S$ ($V_{S,\;drop}$) in the fabricated a-IGZO TFT under both bias stresses. A significantly higher RS and $V_{S,\;drop}$ are extracted under the bias stress ($V_{GS}$, $V_{DS}$) of (22 V, 20V) than (24 V, 15.9 V), which implies that the high horizontal electric field across the source contact due to the large voltage drop at the reverse biased Schottky junction is the dominant physical mechanism causing the asymmetrical degradation of a-IGZO TFTs under simultaneous gate and drain bias stresses.

건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구 (A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings)

  • 김동진;김영선;이기식
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.