• Title/Summary/Keyword: hook effect

Search Result 95, Processing Time 0.019 seconds

A Study on Performance Evaluation of CEA kits (CEA 키트들 간의 성능 평가에 대한 고찰)

  • Ha, Dong hyuk;Sin, Hee Jung;You, Tae min;Noh, Kyoung Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.76-79
    • /
    • 2018
  • Purpose Carcinoembryonic antigen (CEA) is cell-surface 180-200 kDa glycoprotein that is overexpressed in breast, stomach pancreas, lung, and colorectal cancers. CEA was first described in 1965 by Gold and Freedman and then serum CEA of colorectal cancer patients was first measured in 1969 by radioimmunoassay by Thomson. CEA is currently most widely used tumor marker in the clinic for management of colorectal cancer. Various CEA test kits have been developed and commercialized. CEA kits from different manufacturers might have different test results because of different reagents and protocol. The purpose of this study was to compare results of four commercial available CEA kits. Materials and Methods This study was designed to evaluate four commercially available CEA kits using serum samples acquired from 120 patients who visited our clinic. Test results were compared and analyzed according to the respective test methods. High concentration samples were diluted with saline and diluted solution. Results All of the four kits showed a significant correlation within the reference value. However, three of the four kits used for the dilution test using high concentration samples showed the hook effect. Conclusion Results of the present study showed that It is important to establish the standardized dilution standards for the high-concentration specimens to manage the error of the test result by the hook effect.

Modulation of Inula racemosa Hook Extract on Cardioprotection by Ischemic Preconditioning in Hyperlipidaemic Rats

  • Arun Kumar Tiwari;Pushpraj S Gupta;Mahesh Prasad;Paraman Malairajan
    • Journal of Pharmacopuncture
    • /
    • v.25 no.4
    • /
    • pp.369-381
    • /
    • 2022
  • Objectives: Hyperlipidemia (HL) is a major cause of ischemic heart diseases. The size-limiting effect of ischemic preconditioning (IPC), a cardioprotective phenomenon, is reduced in HL, possibly because of the opening of the mitochondrial permeability transition pore (MPTP). The objective of this study is to see what effect pretreatment with Inula racemose Hook root extract (IrA) had on IPC-mediated cardioprotection on HL Wistar rat hearts. An isolated rat heart was mounted on the Langendorff heart array, and then ischemia reperfusion (I/R) and IPC cycles were performed. Atractyloside (Atr) is an MPTP opener. Methods: The animals were divided into ten groups, each consisting of six rats (n = 6), to investigate the modulation of I. racemosa Hook extract on cardioprotection by IPC in HL hearts: Sham control, I/R Control, IPC control, I/R + HL, I/R + IrA + HL, IPC + HL, IPC + NS + HL, IPC + IrA+ HL, IPC + Atr + oxidative stress, mitochondrial function, integrity, and hemodynamic parameters are evaluated for each group. Results: The present experimental data show that pretreatment with IrA reduced the LDH, CK-MB, size of myocardial infarction, content of cardiac collagen, and ventricular fibrillation in all groups of HL rat hearts. This pretreatment also reduced the oxidative stress and mitochondrial dysfunction. Inhibition of MPTP opening by Atr diminished the effect of IrA on IPC-mediated cardioprotection in HL rats. Conclusion: The study findings indicate that pretreatment with IrA e restores IPC-mediated cardioprotection in HL rats by inhibiting the MPTP opening.

The effects on the size selectivity for Muraensox cinereus, daggertooth pike conger in the coastal longline fishery (연안연승에서 어획되는 갯장어의 크기 선택성에 미치는 효과 분석)

  • KOH, Eun Hye;JANG, Choong-Sik;CHO, Youn-Hyoung;AN, Young-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.4
    • /
    • pp.292-298
    • /
    • 2020
  • The effects on the size selectivity for Muraenesox cinereus caught by coastal longline fishery were investigated in the southern coast of Korea from June 2 to 17, 2019. Four sizes of hooks (sizes 15, 17, 18 and 19) and two sizes of bait (sizes 9.9 g and 18.3 g) were tested in seven and three fishing trials, respectively. Such results revealed that smaller hook and bait size improved capture efficiency. And our results demonstrate that there was no significant size selectivity effect for hook size (ANOVA, p>0.05), but small bait improved on catching smaller fish (ANOVA, p<0.05).

The effect of repeated Korean pop song on 'misery loves company' (https://www.youtube.com/watch?v=DRPJZ3iH71Q)

  • Ko, Kyung Ja
    • CELLMED
    • /
    • v.8 no.4
    • /
    • pp.21.1-21.2
    • /
    • 2018
  • The aim of this article is to argue that repeated singing helps to feel 'misery loves company.' Folksong is popular music in the past. Korean folk songs have almost repetitive chorus. The repetitive refrain is made easy for everyone to follow. So, people become comrades who share the chorus together. Repetitive music makes people more intimate and more intimate. So, people feel that they share thoughts and feelings with music. It gives me energy to never give in to destiny. So, they encourage each other to be worth living. They sing together and sympathize and comfort each other's pain. 'Hook song' is the most popular form in these days in Korean music. The form of K-pop (Korean pop), which is gaining popularity worldwide, has many repetitions and concentration of melody. BTS (Bang Tan Sonyundan, Boyband) also tells teens around the world through repetitive melodies that "Let's share our joy and sorrow." This is the highest value of music therapy. BTS is a Korean boy band that has gained a worldwide reputation. Recently, their songs are affecting teenagers all over the world. In this way, the author thinks that the repetition of folk songs was reborn as a 'Hook song' and the repetitive form of music is a good way to give support to anyone. The author thinks this is best accomplished by singing 'misery loves company.'

Effect of Non-homologous Spacing in Target DNA Sequence on the Frequency of Cloning Based Homologous Recombination (Target DNA 염기서열 내에 존재하는 비상동성 간격이 상동성재조합을 이용한 클로닝 빈도에 미치는 영향)

  • Kim Jae-Woo;Do Eun-Ju;Yoon Se-Lyun;Jeong Yun-Hee;Yoon Young-Ho;Leem Sun-Hee;Sunwoo Yangil;Park In-Ho
    • Korean Journal of Microbiology
    • /
    • v.41 no.4
    • /
    • pp.239-245
    • /
    • 2005
  • Transformation-Associated Recombination (TAR) cloning technique allows selective isolation of chromosomal regions and genes from complex genomes. The procedure requires knowledge of relatively small genomic sequences that reside adjacent to the chromosomal region of interest. This technique involves homologous recombination during yeast spheroplast transformation between genomic DNA and a TAR vector that has 5' and 3' gene targeting sequences. In this study, we examined the effect of non-homologous spacing sequence in target hooks on homologous recombination using a plasmid model system. The efficiency of homologous recombination between the modified his3-TRP1-his3 fragments and HlS3 gene on plasmid were analyzed by the characterization of $Ura^+$ transformants. The numbers of $Ura^+$ transformant showed same level when seven different modified his3-TRP1-his3 fragments were used. But the percentage of positive recombinants. $Trp^+His^-$, dramatically decreased when used the modified his3-TRP1-his3 fragments contained incorrect spacing of nonhomologous region. As a result, we suggest that incorrect spacing inhibits the homologous recombination between target hook and substrate DNA. Therefore, we should consider the correct spacing in target hook when the target hook are used for cloning of orthologue gene.

Simplification of One Step Immunotech AFP Test (AFP 검사방법 단축에 관한 고찰)

  • Moon, Ki Choon;Kwon, Won Hyun;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.80-84
    • /
    • 2013
  • Purpose: The Immunotech AFP is a widely used test in 14 hospitals(RIA QC establishments: 46) as a liver tumor marker. Normally, the test takes 45 minutes including complicated 2 step method. We evaluated the possibility of 1 step method and suitable test time. Materials and Methods: Samples of 31 patients in SNUBH were used as subject. We evaluated the sensitivity, intra and inter assay precision, recovery rate, linearity between 1 step and 2 step method (45 min. and 60 min.). Results: Both of 45 minutes and 60 minutes test showed 0.1 ng/mL sensitivity. In 45 minutes test, the intra assay coefficients of variation were 3.05%, 3.43%, 1.68%. Also, inter assay coefficients of variation were 3.91%, 2.38%, 0.82%. In 60 minutes test, the intra assay were 5.00%, 3.69%, 1.97%, inter assay were 3.14%, 3.71%, 1.85%.The correlation coefficient of each 2 step and 1 step (45 min.), 2 step and 1 step(60 min.), 1 step (45 min.) and 1 step (60 min.) were y=0.9293x+2.7356 ($R^{2}=0.9999$), y=0.9193x+4.1002 ($R^{2}=0.9993$), y=0.9894x+1.3805 ($R^{2}=0.9997$). Conclusion: Compared 1step method to 2 step method, both method showed very reasonable precision, recovery rate and correlation coefficient. Also, 1 step method(45 min.) of correlation coefficient ($R^2$) was 0.999. We suggest that 1 step method test can reduce the test time and is useful for AFP test.

  • PDF

Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay (면역방사계수측정법의 민감도 향상을 위한 변법의 평가)

  • Won-Hyun Kwon;Mi-Ji Kang;;Ji-Sol Park;Jung-In Kim;Kyung-Jae Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF

A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results (CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구)

  • Jae-Seok An;Ji-Na Kim;Kwang-Seo Park;Eun-Bit Joo;Sang-Hyuk Yoon;Yoon-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

The Effect of Components and yield with Different Temperature Codonopsis lanceolata Benth. et Hook . fil. (온도의 차가 더덕 ( Codonopsis lanceolata Benth , et Hook. ) 의 수량 및 성분함량에 미치는 영향)

  • 이상래
    • Korean Journal of Plant Resources
    • /
    • v.5 no.1
    • /
    • pp.11-23
    • /
    • 1992
  • The experiments tvere carried out to different temperature which affected growth, yield, proximate and antitumor activity in the Codonopsis lanceolata. Growth of aerial part and subterranean partwere best at 2$0^{\circ}C$ and lower 3$0^{\circ}C$. Components of fat, protein and fiber were best at 3$0^{\circ}C$. Wild C.fonceoforo had higher contents of fat, protein, fiber and ash as compared with cultur'ed C.lanceolataArginin was predominant amino acid in both wild and cultivated C.laceolata No significant differ-ence in the mineral contents was found between the wild root and the cultivated at 30'c inbiotronroom. No minerals difference in the contents was found between the cultivated temperature.The content of elements of inorganic metal differs according to the part. C. lanceolata were subjectedto preliminary antitumer screening test with Sarcoma 180 ascites and screening on V-79 cell. Thisexperiments were conducted in accordance with the total packed cell volume method and cytotoxicity method.

  • PDF