• Title/Summary/Keyword: homogeneous region

Search Result 331, Processing Time 0.028 seconds

The Myth of Youthism (청소년주의와 세대 신화)

  • Won, Yong-Jin;Lee, Dong-Yeon;Nho, Myung-Woo
    • Korean journal of communication and information
    • /
    • v.36
    • /
    • pp.324-347
    • /
    • 2006
  • `Youthism` is pushing the youth research field into a trap of binarism fallacy. It tends to divide the whole population into the young and the old, and further gives an acceleration toward moving the division into the discursive realm of generation gap. The discursive transference is not taking place without any reasonable grounds. The series of discourse is based on two significant phenomena: changes in media background and longer schooling than ever before. Media environment overriding youth culture binds the young in a group and makes them enjoy homogeneous cultural genres. And schooling also seems to play an important role for the youth to have same cultural menus regardless of region, social strata, cultural background. But we need to recognize that after getting into the adulthood, they are not existing in the form of alliance. The youth are not in a homogeneous group. Neither are their culture. The youth are consisted of a variety of groups along such variables as gender, class of their parents. They tend to make distinction not only from the older generation but from the other peer groups. Unless avoiding the trap of youthism, we are blamed for closing eyes to the youth's desire to be distinctive among themselves. Youthism seems to be an active myth even in our academic society.

  • PDF

A Derivation of Rainfall Intensity-Duration-Frequency Relationship for the Design of Urban Drainage System in Korea (우리나라 도시배수시스템 설계를 위한 확률강우강도식의 유도)

  • Lee, Jae-Jun;Lee, Jeong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.4
    • /
    • pp.403-415
    • /
    • 1999
  • This study is to derive the rainfall intensity formula based on the representative probability distribution in Korea. The 11 probability distributions which has been widely used in hydrologic frequency analysis are applied to the annual maximum rainfall. The parameters of each probability distribution are estimated by method of moments, maximum likelihood method and method of probability weighted moments. Four tests such as $x^2$-test, Kolmogorv-Smirnov test, difference test and modified difference test are used to determine the goodness of fit of the distributions. The homogeneous tests (Mann-Whitney U test, Kruskal-Wallis one-way analysis of variance of nonparametric test) are applied to find the stations with rainfall homogeneity. The results of homogeneous tests show that there is no representative appropriate distribution for the whole duration in Korea. The whole region could be divided into five zones for 12-durations. The representative probability distribution of each divided zone for 12-durations was determined. The GEV distribution for I,II,V zones and the 3-parameter Weibull distribution for III,IV zones were determined as the representative probability distribution. The rainfall were obtained from representative probability distribution for the selected return periods. Rainfall intensity formula was determined by linearization technique for the rainfall.

  • PDF

Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

  • So Yeon Cha;EunJu Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.922-930
    • /
    • 2021
  • Objective: It is uncertain why a b-value range of 1500-2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. Materials and Methods: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. Results: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm2 and 1640-1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835-1895 s/mm2 and 1705-1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm2 and 1573-1867 s/mm2 for reader 1, and 1775-1945 s/mm2 and 1591-1955 s/mm2 for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values. Conclusion: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm2.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

Generating Pylogenetic Tree of Homogeneous Source Code in a Plagiarism Detection System

  • Ji, Jeong-Hoon;Park, Su-Hyun;Woo, Gyun;Cho, Hwan-Gue
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.6
    • /
    • pp.809-817
    • /
    • 2008
  • Program plagiarism is widespread due to intelligent software and the global Internet environment. Consequently the detection of plagiarized source code and software is becoming important especially in academic field. Though numerous studies have been reported for detecting plagiarized pairs of codes, we cannot find any profound work on understanding the underlying mechanisms of plagiarism. In this paper, we study the evolutionary process of source codes regarding that the plagiarism procedure can be considered as evolutionary steps of source codes. The final goal of our paper is to reconstruct a tree depicting the evolution process in the source code. To this end, we extend the well-known bioinformatics approach, a local alignment approach, to detect a region of similar code with an adaptive scoring matrix. The asymmetric code similarity based on the local alignment can be considered as one of the main contribution of this paper. The phylogenetic tree or evolution tree of source codes can be reconstructed using this asymmetric measure. To show the effectiveness and efficiency of the phylogeny construction algorithm, we conducted experiments with more than 100 real source codes which were obtained from East-Asia ICPC(International Collegiate Programming Contest). Our experiments showed that the proposed algorithm is quite successful in reconstructing the evolutionary direction, which enables us to identify plagiarized codes more accurately and reliably. Also, the phylogeny construction algorithm is successfully implemented on top of the plagiarism detection system of an automatic program evaluation system.

The Study of Reaction Bonded Silicon Nitride Fabricated Under Static Nitrogen Pressure (일정 질소압에서 제조된 반응결합 질화규소에 관한 연구)

  • Choi, Myoung-Je;Roh, Tae-Wook;Park, Chan;Park, Dong-Soo;Kim, Hai-Doo
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.5
    • /
    • pp.505-510
    • /
    • 2000
  • In this investigation, we fabricated RBSN (Reaction Bonded Silicon Nitride) using the static nitriding system which could be advantageous for commercialization. Firstly, Si compacts of different sizes were made, and then nitridation rates were investigated as a function of added static gas pressure. The reaction schedule was obtained by pre-experiments. In case of small samples, the variation of ${\alpha}$, ${\beta}$ phases between the inside and the outside region of the specimens was examined after the samples were nitrided under 1 bar and 1.5 bar reaction pressure. On the other hand, large samples of Si compact with the size of 36 mm for diameter and 23 mm for thickness were nitrided for 26 hours of the total nitridation time, which showed a complete and homogeneous nitriding reaction from the outside to the inside of the samples, although the time was considerably shorter than that needed for convertional nitridation. Nitridation rates obtained at the early stage of reaction were proportional to the reaction gas pressures. The sequences of the nitridation reaction with the thickness were as follows 1) the outside, 2) the inside and 3) the intermediate area of the specimen. These results wer eobtained from the coloration of cross sectioned specimens that had various nitridation rates. Total nitriding reaction kinetics was controlled by chemical reaction, not by diffusion of the nitrogen gas.

  • PDF

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

Enhanced Electrical Conductivity of Gold Doped Graphene Films by Microwave Treatment

  • Kim, Yoo-Seok;Song, Woo-Seok;Cha, Myoung-Jun;Lee, Su-Il;Cho, Ju-Mi;Kim, Sung-Hwan;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.188-188
    • /
    • 2012
  • Graphene, with its unique physical and structural properties, has recently become a proving ground for various physical phenomena, and is a promising candidate for a variety of electronic device and flexible display applications. Compared to indium tin oxide (ITO) electrodes, which have a typical sheet resistance of ${\sim}60{\Omega}$/sq and ~85% transmittance in the visible range, the chemical vapor deposition (CVD) synthesized graphene electrodes have a higher transmittance in the visible to IR region and are more robust under bending. Nevertheless, the lowest sheet resistance of the currently available CVD graphene electrodes is higher than that of ITO. In this study, we report a creative strategy, irradiation of microwave at room temperature under vacuum, for obtaining size-homogeneous gold nano-particle doping on graphene. The gold nano-particlization promoted by microwave irradiation was investigated by transmission electron microscopy, electron energy loss spectroscopy elemental mapping. These results clearly revealed that gold nanoparticle with ${\geq}30$ nm in mean size were decorated along the surface of the graphene after microwave irradiation. The fabrication high-performance transparent conducting film with optimized doping condition showed a sheet resistance of ${\geq}100{\Omega}$/sq. at ~90% transmittance. This approach advances the numerous applications of graphene films as transparent conducting electrodes.

  • PDF

Plasma Hormones, Blood Metabolites, Milk Yield and Composition in Early Lactation of Buffaloes Treated with Bromocryptine

  • Saha, A.;Singh, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.4
    • /
    • pp.368-374
    • /
    • 1998
  • The study was conducted on six multiparous Murrah buffaloes which were earlier artificially induced into lactation. During the experimental period of 15 days, buffaloes were managed in a loose housing system. All the buffaloes were administered a single injection of bromocryptine (@ $100{\mu}g/kg$ body weight) subcutaneously in the neck region at 08:30 A.M., 50 days postpartum (early lactation). Blood samples were collected from four buffaloes for a period of 5 days before the administration of bromocryptine i.e. on days -5, -4, -3, -2, -1, on day of treatment (day 0) and thereafter daily for a period of 9 days i.e 1, 2, 3, 4, 5, 6, 7, 8 and 9 to determine the hormones and blood metabolites. Homogeneous milk samples from all the buffaloes were collected at morning and evening milkings on days coinciding with the days of blood sampling for analysis of milk constituents. Administration of bromocryptine resulted in a significant inhibition of plasma prolactin within 24 hrs of treatment, but the response in all the buffaloes was not uniform. The effect of bromocryptine on plasma prolactin hormone lasted for 1-4 days but Cortisol concentration were not altered. Administration of bromocryptine neither affected blood glucose nor plasma non-esterified fatty acids concentration. Irrespective of level of milk production from different buffaloes, there was no effect of bromocryptine on milk yield which indicated that prolactin is not required for milk secretion during early lactation in buffaloes. Milk constituents like fat, protein and lactose were not affected by bromocryptine may be due to no effect of bromocryptine of milk yield.

Fast Acoustic Radiation Force Impulse Imaging Using Non-focused Transmission in Medical Ultrasound Imaging (초음파 의료 영상에서 비집속 송신을 이용한 고속 음향 복사력 임펄스 영상법)

  • Choi, Seung-Min;Park, Jeong-Man;Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.151-160
    • /
    • 2012
  • In medical ultrasound imaging, elasticity imaging helps to diagnose tumors such as cancer. This paper is concerned with the application of acoustic radiation force to soft tissue of interest to implement elasticity imaging. In order to reduce the data acquisition time, instead of relying on transmit focusing, a plane wave of burst type is transmitted to apply the acoustic radiation force simultaneously to an entire imaging region to be observed. A homogeneous phantom experiment confirms that increasing the transmit excitation duration instead of employing transmit focusing generates a high enough acoustic radiation force to obtain elasticity images. It is found, however, that a different displacement versus time characteristic is observed unlike the case of using a conventional focused acoustic radiation force. Experimental results obtained through the use of an ultrasound phantom and a bovine liver show that lesions can be correctly differentiated.